ORDINARY MEETING MINUTES 15 NOVEMBER 2018
93. Certification must be submitted to Council from a qualified person which certifies
that all outdoor lighting devices comply with the requirements of this Decision
Notice at the time of commissioning.
For the purpose of certifying outdoor lighting devices for the development, a
qualified person is:
a. Registered Professional Engineer of Queensland;
b. an environmental or electrical design consultant with a minimum of 3 years
current experience in the field of outdoor lighting.
WASTE
94. The developer must provide waste storage and disposal facilities in accordance
with Planning Scheme Policy No. 9 "Waste Management Multi-Dwellings and
Commercial and Industrial Premises". The facilities must include an external
impervious area correctly sized for all refuse and recycling containers and
suitably screened from public places and neighbouring properties. A bin wash
area is required with a cold-water tap, hose and drain outlet connected to sewer,
via a bucket trap. The drain outlet must be designed to prevent storm water entry
to the sewerage system. This can be achieved with a nib wall 50mm high and up
to 700mm x 700mm wide (max 0.5m2) , or alternatively the waste area can be
roofed, or any other design approved by Council.
95. Refuse containers must be provided in accordance with the requirements of the
Environmental Protection (Interim Waste) Regulation 1996 and (Waste
Management) Regulation 2000, for the storage and collection of refuse.
96. Bins must be provided throughout the site to reduce littering. All bins provided
must be for refuse and recycling and be decanted into the bulk bins by the site
operators.
ENGINEERING
Site Access and Driveways
97. A sealed access driveway must be provided from Pacific Avenue to all parking
and manoeuvring areas of the development. The new works proposed to access
No 106 must be undertaken in accordance with an Operational Works approval
and must include in particular:
a. a driveway crossover generally in accordance with Council’s Standard
Drawings RS-051 and the associated addendum
b. the works must match neatly with existing road and verge/footpath
features. Additional works beyond the driveway may be required to provide
an acceptable transition to existing road and verge/footpath profiles
Car Parking
98. A minimum of an additional 2 car parking spaces must be provided and marked
on the site. The works must include dimensions, crossfalls and gradients in
accordance with Australian Standard AS2890: Parking Facilities for the relevant
user class
99. All car parking areas and access driveways must be maintained exclusively for
vehicle parking and manoeuvring and kept in a tidy and safe condition at all times.
100. Directional signage must be provided to direct visitors and customers to the car
parking spaces provided on site.
Pedestrian and Bicycle Facilities
101. Pedestrian and bicycle facilities must be provided for the development. The