Original source · versioned page text
Operational Work Application
“Adamson Town Planning, specialising in providing higher order town planning advice”
An assessment is also provided below demonstrating compliance with each of the most
relevant acceptable and performance outcomes.
Relevant assessment benchmarks:
• PO8 – Complies, the proposal includes a driveway and access plan (Dwg No. 0387-
OW2.1) with a maximum width of 4.0 metres at the kerb and 3.5 metres at the property
boundary, consistent with Standard Drawing RS-049. The driveway details plan (Dwg
No. 0387-OW2.2) also provides Section A-A – Driveway Profile, designed to meet
existing site constraints and will minimise any stormwater impacts of the site. The
proposed driveway will provide safe access to and from the site for use by vehicles and
pedestrians to the extent practicable, having regard to the steepness of the footpath
area in this location, consistent with PO8 (refer Attachment 2).
• PO10 – Complies, the driveway and crossover will be constructed of concrete, which is
suitable and practical.
• PO11 – Complies, the proposed driveway will not cause water ponding and will not
enter buildings. Further, it will not reduce the stormwater carrying capacity of the
roadway.
• PO12 - Complies, the driveway and access plan (Dwg No. 0387-OW2.1) demonstrates
the proposed driveway crossover is not located near stormwater drainage
infrastructure.
• PO13 – The proposed driveway and crossover are in the same location, well removed
from the Tree Protection Zone (TPZ) for the existing tree located in the road reserve to
the east of the driveway (see Dwg No. 0387-OW1.1 and Attachment 2). The proposal
minimises adverse impacts on the streetscape and traffic network by utilising the
current crossover location to service the site. The proposed design will not have a visual
impact on the streetscape.
• AO14 – Complies, the proposal seeks to construct one (1) driveway, is not on a corner
lot, and is located within the Low Density Residential Zone. Further, will not impede the
safe and efficient use of the road network.
• AO15 – Not applicable, the site is not mapped within a Bushfire hazard area.
• AO16 - Not applicable, the site is not mapped within a Flood hazard area.
• AO17 – Not applicable, the proposal does not include underground parking.
• AO18 – Not applicable, the proposal is not within proximity to a substation or
transmission line.
2|Page
Driveway for Dwelling House – 5 Bowman Terrace, Sunshine Beach
See the original