Noosa Iconic Panel Decision Notice — Approval with conditions
Material change of use (Visitor Accommodation Type 4 - Conventional, Entertainment & :
Dining Business Type 1 — Food & Beverages, & Retail Business Type 2 — Shop & Saton)
9, 11, 13 & 19 Hastings Street, Noosa Heads
21 May 2009
The certification is required immediately after installation of the equipment and prior to
any occupation of the building, and in a format approved by Council. This assessment |
must take into account noise from any other fixed equipment on the property e.g.
swimming pool pump, heating/cooling equipment, etc that may increase the overall
noise level emitted.
Kitchen Exhaust
106. Any commercial kitchen exhaust points must be located and operated in accordance
with AS1668.2 “The use of ventilation and air conditioning in buildings — Ventilation
design for indoor air contaminant control”, Section 5 — Mechanical Ventilation —
Exhaust Systems, 5.10 Air Discharges. ,
Restaurant Facilities
107. The two food businesses shall be provided with a common cleaner’s sink facility &
storage area for recycled cooking oil.
Trade Waste
108. The drainage system from all business that are likely to discharge trade waste must
comply with Council’s Trade Waste Policy and Sunshine Water’s guidelines for
" accepting trade waste into the sewer. All appropriate trade waste permit and/or
agreements must be applied for and issued prior to the discharge of any trade waste to
the sewer.
109. Based on the information currently available, the minimum requirements for the pre-
treatment of trade waste discharged from the two food and beverage premises will be
two 2000 litre grease arrestors, i.e. a 2000 litre arrestor for each premises.
If additional commercial food kitchens are proposed to operate in any other premises
additional grease arrestors will also be required for these premises.
The trade waste requirements will be fully assessed when hydraulic drawings are
submitted to Council
Si 8 REFERRALAGENCY CONDITIONS 73.28 3. aR ey ee Se
The referral agencies applicable to this application are:
Referral Trigger . | Referral Status | Referral Agency | - ‘Referral Address °
Sites in Coastal Concurrence Environmental Ecoaccess Customer Service ,
Management District with Protection Agency Unit PO
premises with GFA of at Box 15155
least 1000m2 CITY EAST QLD 4002
. A copy of the referral agency conditions is attached at Attachment A.
62=)APPROVED PLANS/DOCUMENTS 7 ons a EM
The plans and / or documents recommended for approval are listed in the following table:
Plan No. | Rev.” | Plan/DocumentName _. | Date
sk1000 DAO2 Site Plan —- Arkhefield & Foster Designs 2 February 2009
sk2000 DAO2 Lower Ground Level Plan — Arkhefield & Foster Designs | 2 February 2009 '
“sk2001 | DA02 | Podium Level Plan — Arkhefield & Foster Designs 2 February 2009
Page 17 of 20 ,See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
001A9301.001.pdfRelated documentPublic source context ↗
08/1787 - Decision Notice & Approved Plans - Noosa Iconic Panel [As Published]Related documentApplication case desk ↗
About this file
- File size
- 8.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.