Council archive · source document
Decision Notice - 010.2007.00001255.001 [As Published] · 152007.1255
NOOSA COUNCIL IDAS Development Application Decision Notice 5 of 9
Sewer Connection and Easement
21. A Sewer connection shall be provided to the proposed additional lot (Lot 2) in accordance with Council’s
standards and requirements.
22. A registered easement shall be created over the zone of influence of all sewers within the subject site and
over those parts of the subject site that are impacted upon by sewers on any adjoining sites. The
easements shall generally be parallel to and centred over the sewer main and be equivalent in width to
twice the depth to invert level of the sewer at the deepest point within the allotment (measured from the
finished surface) and be no less than 3.0m wide overall. In this regard a licensed surveyor shall
accurately locate all sewer mains and determine the necessary width of the easement, which shall be
shown on any plans submitted for Operational Works and Building Works approvals. To this extent the
surveyor shall certify that the sewer and the zone of influence is wholly contained within the easement to
be created.
In addition to this the Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in
writing that the Title Deed and the easement documents will be lodged at the Land Titles Office and any
additional Titles Office forms or requisitions requiring the consent of Council will be attended to promptly.
A duly executed copy of the easement shall be submitted to Council for perusal prior to the use
commencing.
Any changes required by Council’s Solicitor must be corrected immediately.
Town Water Supply
23. Each lot shall be connected to Council’s existing town water supply and be constructed in accordance
with Council’s standards and requirements at no cost to Council.
24. Each individual water connection to the water reticulation system shall extend to the property boundary
and be metered. All fees for the supply of water meters shall be paid to the Council.
25. All water meters must be located outside the property boundary and in an easily assessable location to
facilitate unhindered reading by Council and/or Council’s contracted water meter readers.
Power Supply
26. An underground electricity service shall be provided to each allotment if not already provided.
In this regard, an approved ENERGEX Electrical Design Consultant shall work in conjunction with
Council’s Manager - Works Support to prepare detailed designs of the electrical proposal.
The detailed deigns shall then be submitted to ENERGEX for approval and a copy of their approval
submitted to Council in conjunction with a “Certificate of Electricity Supply for Proposed Subdivisions”
(prepared by an approved ENERGEX Electrical Design Consultant) prior to Council endorsing the Plan of
Survey.
Any agreement with ENERGEX or an approved ENERGEX Electrical Design Consultant shall be wholly at
the applicant’s expense and shall not entail a financial encumbrance on future purchasers of the proposed
lots.
Telecommunication
27. The requirements for TELECOMMUNICATION services shall be satisfied in relation to the provision of
new underground telephone services to the proposed lots. In this regard written confirmation from an
approved telecommunication agency shall be submitted to the Council prior to Council endorsing the Plan
of Survey.
Erosion and Sediment Control
28. Any person acting on this permit shall prevent erosion and sediment export from leaving the site. Site
control measures such as silt fencing, controlled gravel access to the site and controlled disposal of
waste, will be necessary.
Contributions Towards Council Infrastructure
29. Monetary contributions shall be paid to Noosa Council towards the cost of providing and/or upgrading
various infrastructure at the rates applicable at the time of payment. An estimate only of the contribution
amounts under the current Council policies and requirements is outlined in the table below:
NSC c:\docume~1\rhr\locals~1\temp\bcl technologies\easypdf 5\@bcl@380d2440\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - 010.2007.00001255.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 40 KB (small file)
- File type
No other editions are linked here.