Water Quality and Drainage Code
Noosa Council Plan July 2020
Performance and Acceptable Outcomes Table
Version: 2020
Performance Outcomes Acceptable Outcomes Solution1 Comments Council Use
techniques.
AO8.3
Vegetated stormwater management systems
to be dedicated as public assets are
established and maintained during the
maintenance period to ensure optimal N/A
vegetated growth and that the functional
elements of the system achieve the design
function at the end of the maintenance
period.
PO9 AO9.1 RO9.1
Treatment systems are designed to eliminate or Free draining inlets and outlets are provided The proposal complies. The proposed
minimise health, safety and aesthetic hazards, to ensure that waters do not pond for more stormwater treatment system will be
including risks associated with insect breeding, than 24 hours. design to be free draining.
odour and public safety. AO9.2
Developments are designed to eliminate
N/A
retaining walls in excess of 0.8m for any
water quality treatment device.
Hydraulic and Waterway Stability
PO10 AO10 RO10
Development prevents increased bed and bank The development is designed to: The proposal complies. Refer to the
erosion and sedimentation in receiving waterways (a) limit the peak 1 year ARI event discharge SBSMP prepared by MCE.
by avoiding changes in low rate, peak flow run-off within the receiving waterway to the pre-
and flow duration. development peak 1 year discharge;
(b) maximise pervious areas by using
pervious alternatives for otherwise
impervious areas wherever possible;
(c) provide for capture and reuse of
stormwater for non-potable purposes for
gardening, toilet flushing, laundry and hot
water supply uses;
(d) incorporate appropriate detention
features; and
(e) incorporate natural channel design
principles.
1
Solution: Acceptable Solution Page 5 of 10
A/S Alternative Solution D:\JOBS\20-Jobs\20169 - 101 & 105 Eumundi Noosa Road, Noosaville\Civil\Reports\SBSMP\Working\Appendices\20169 - NSC Water Quality and Drainage Code 2020.docx
N/A Not applicable to this proposal Job: 20169
Rev: 0
Site Address: 101-105 Eumundi Noosa Road, Noosaville 30/11/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.