SITE DETAILS
unit 1 + 2/35 karathina street, noosa heads qld 4567 RESPONSIBILITY CANNOT BE TAKEN FOR SITE LEVELS
lot 125 on RP9258
LOT 125 NEW GROSS FLOOR AREA 234M2 THEREFORE THE BUILDER SHOULD VERIFY THESE LEVELS
NEW PLOT RATIO 0.45:1 BEFORE COMMENCING ANY WORK
CUT AND FILL, LEVELS SHOWN ON THIS PLAN ARE APPROXIMATE
INTERPRETATION, AND MAY VARY TO FINISHED LEVELS ON SITE
AT COMMENCEMENT AND COMPLETION OF WORKS
PLATFORM IMMEDIATELY SURROUNDING RESIDENCE TO
FALL AWAY FROM RESIDENCE AT A SLOPE OF 1 IN 15MIN.
17.102
DRIVEWAY SLOPE NOT TO EXCEED A MAX 1 VERTICAL TO
273d56'
4 HORIZONTAL APPROX.
1000MAX HIGH TIMBER RETAINING WALLS TO HAVE 65mm DIA. AG. PIPE
(DISCHARGE TO STORMWATER) + GRADED GRANULAR BACK FILL
BEHIND AND TO BE CONTAINED WITHIN SITE
RETAININING WALLS EXCEEDING THIS ARE TO BE ENGINEERED ALSO
DISPOSE SEWERAGE IN ACCORDANCE WITH LOCAL AUTHORITY
PREPARED DRAINAGE PLAN
DISCHARGE ALL STORMWATER TO COUNCIL S/WATER SYSTEM
(DOWNPIPE DESIGN, SIZE AND LOCATION BY BUILDER AND ROOFING
REQUIREMENTS, AND MAYBE ADJUSTED TO SUIT SITE CONDITIONS.
DOWNPIPES:
90DIA OR 100x50 DOWNPIPES TO STORMWATER PIPES 100mm MIN
existing existing COVER 1 IN 100MIN FALL
unit 2 unit 1 TERMITE PROTECTION
183d56'
30.190
30.190
BUILDER TO PROVIDE TERMITE CONTROL SYSTEM IN ACCORDANCE
3d56'
WITH AS.3660.1
proposed proposed TERMITE PROTECTION GENERALLY SHALL BE BY GROUND FLOOR SLAB
balcony build in balcony build in AS BARRIER AND EXPOSED EDGE OF SLAB AS VISUAL BARRIER
TERMI MESH OR SIMILAR COLLARS TO SLAB PENETRATIONS
TERMITE RESISTENT (HAZARD LEVEL H2) TIMBER FRAMING GENERALLY
BUILDER TO PROVIDE ACCESS FOR CLEAR VISUAL INSPECTIONS TO THE
ENTIRE PERIMETER OF THE HOUSE, AND THE EXPOSED EDGE OF
CONCRETE SLABS
ENERGY EFFICIENCY
ALL TOILETS TO BE INSTALLED WITH 3/4.5 DUAL FLUSH CISTERNS OR BETTER
ALL SHOWER HEADS TO HAVE CERTIFIED AAA WATER CONSERVATION RATING
ALL TAPS TO HAVE CERTIFIED AAA WATER CONSERVATION RATING
ENERGY EFFICIENT LIGHTING TO BE USED FOR MIN OF 80% OF FLOOR AREA
HOT WATER SYSTEM TO BE GAS BOOSTED SOLAR HOT WATER SYSTEM
TOTAL SITE AREA 516m2 (OR OTHER APPROVED) OF SIZE TO SUIT REQUIREMENTS.
GENERAL
17.102
93d56'
ALL CONSTRUCTION METHODS AND MATERIALS TO BE IN ACCORDANCE WITH:
THE BUILDING CODE OF AUSTRALIA
KATHARINA STREET THE BUILDING ACT 1975
STANDARD BUILDING REGULATION 1993
BUILDING REGULATION 2006
NOTE TO BUILDER: QDC QUEENSLAND DEVELOPMENT CODE
AS 1684-2006 TIMBER FRAMING CODE
IF ANY DISCREPANCIES ARISE IN THE CERTIFICATION
PROCESS, AND BUILDING WORKS HAVE COMMENCED ALL TIMBER FRAMED WALLS TO WET AREAS TO BE LINED WITH FC
NO RESPONSIBILITY IS TAKEN FROM THE COMPLETED WC'S TO BE A MIN CLEAR FINISHED WIDTH OF 900mm
DESIGN AND DRAFTING. IT IS A REQUIRED PART OF THE DOORS TO WC'S TO HAVE LIFT OFF HINGES
BUILDING AND PLANNING OF INDIVIDUAL PROJECTS TO SMOKE ALARMS TO BE PROVIDED AS PER BCA & AS3786
CONFIRM COUNCIL PLANNING SCHEME AND BUILDING MASONARY CONSTRUCTION TO BE IN ACCORDANCE WITH AS3700
COMPLIANCE. ALL WET AREA FLOORS AND WALLS TO BE PROTECTED AS PER
CLAUSE 3.8.1 BCA
NOT FOR CONSTRUCTION
BALUSTRADING TO BE 1000MIN ABOVE FINISHED FLOOR LEVEL AND HAVE
125mm MAX SPACING IN BALUSTERS
PROVICE DPC'S AS PER CLAUSE 3.3.4 BCA
site plan
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROVIDE FLASHINGS AS PER CLAUSE 3.3.4, 3.5.1, & 3.5.3 BCA
PROPOSED: CLIENT: HELEN MADDERN BUILDER: CHRISTIAN MANDY'S DESIGN + DRAFTING SHEET: 1 of 6 DATE: ISSUE NO:
BALCONY BUILD IN PH: 0419 296 088 PH: 0422 652 760 QBCC NO: PH: 0403 481 474 QBCC: 15117996 SCALE: 1:200 31 AUG 2026 HM-2026-D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH WITH ENERGY EFFICIENY REPORT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Amended Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.