Approved Plan - 51995.1645.01 (As Published)
Plans and drawings: the text below has words only, no drawings.
TENDER
NOT FOR CONSTRUCTION
GENERAL NOTES:
(these notes apply to all drawings)
• These designs, drawings and specifications are copyright
and the property of Cayas + Ward and must not be used,
reproduced or copied wholly or in part without the
permission of Cayas + Ward.
• Do not scale - use figured dimensions in preference to
scaled dimensions.
• All dimensions must be checked on site prior to the
commencement of construction and/or manufacture of any
item.
• Where demolition work is included, allow to make good all
affected surfaces.
• Ensure that all conditions of the building certification are
complied with.
• Where ambiguities or discrepancies exist, Cayas + Ward
shall be contacted for clarification, or it will be deemed that
the more expensive option has been allowed.
• All work is to comply with all relevant sections of NCC
and/or Australian Standards.
• These drawings are to be read in conjunction with all other
documentation, schedules & consultant documentation.
• The contractor is to allow for all necessary floor preparation
works.
• Provide all warranties as per the manufacturers & suppliers
standard warranties.
• All materials, equipment, fixtures, fittings, etc. Shall be new
first quality without exception. Supply, delivery, storage,
installation, etc. Is to be as per the manufacturers most
recent written recommendations.
EXISTING AWNINGS TO BE REMOVED EXISTING SIGNAGE TO BE MODIFIED • Supply & install fire extinguishers to comply with Australian
SHOWN DASHED Standards to the area of the proposed work.
• Termite protection is to be provided to comply with AS
3660.1-2000 and clarification to be provided on completion.
• The construction and fit out of commercial kitchens and
bars are to comply with AS 4674-2004.
• Builder to inspect existing walls that are proposed to have
new finishes and ensure that a suitable substrate is present
Level 1 or is provided to achieve the specified finish. Builder to
inspect existing walls that are proposed to conceal services
2 3
16.785 and ensure that an adequate cavity is present or provide
furring channels.
1
Upper Ground Floor
13.410
LOCATION OF NEW
OPENING FOR NEW
WINDOW
Lower Ground Floor
10.000
Council Annotation:
Existing + Demolition - West Elevation
These plans refer to approval
1 1 : 100
51995.1645.01 and approve the new works
in red linework only.
EXISTING AWNING TO BE REMOVED EXISTING AWNING TO BE REMOVED
2 3
1 2
EXISTING AWNING TO BE REMOVED
D General Updates RH 16.05.25
C General updates DV 29.04.25
B Consultant Issue RH 12.02.25
A Consultant Issue RH 24.01.25
issue revision initials date
Cayas
+ Ward
Suite 2, 19-25 Musk Avenue, Kelvin Grove. PO Box 360, Wilston Q 4051
p 07 3356 6100 e [email protected]
NSW Nominated Architect: Kimberley James Garton 8891
client ALH Group
EXISTING GAMING ENTRY AWNING EXISTING AWNING EXISTING ENTRY AWNING project Noosa Reef Hotel
19 Noosa Dr, Noosa Heads
QLD 4567
drawing title Existing West Elevation
NOOSA COUNCIL drawn RH
APPROVED PLAN date
scale
MAY 2025
1 : 100@A1
51995.1645.01 1 AUG 2025 project no.
2395
drawing number
A100.04
issue
D
Document Set ID: 23750179
Version: 1, Version Date: 20/05/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plan - 51995.1645.01 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 5.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.