SITE-BASED STORMWATER
   MANAGEMENT PLAN

     In Association with the
  Reconfiguration of a Lot for the
      Proposed Subdivision
                 at

            Noosa Civic
  28 Eenie Creek Road, Noosaville
        Lot 3 on SP246584
                for

         Stockwell Pty Ltd




                             Ref: 1856-SBSMP-01_Version 2.0
                                                 April 2019
Log in to download the original file

Attachment 7- Site Based Stormwater Management Plan.pdf · 5.1 MB (large file)

The download may take up to a minute.

Full text of the other 45 pages

Page 2

DOCUMENT INFORMATION

   Document Title:                                  Site-Based Stormwater Management Plan


   Document Reference No.                           1856-SBSMP-01 – Version 2.0


   Commissioned By:                                 Stockwell Pty Ltd


   Prepared By:                                     Barlow Shelley Consulting Engineers Pty Ltd


   Author:                                          Vincent Vicic (BEng, GradIEAust)


   Reviewed & Authorised By:                        Cameron Landreth (BEng (Hons), NER, RPEQ)


DOCUMENT CONTROL

        Version                         Date                           Author                       Reviewer


           1.0                  8th March, 2019                    Vincent Vicic             Cameron Landreth


           2.0                   17th April, 2019                  Vincent Vicic             Cameron Landreth


“©2019 Barlow Shelley Consulting Engineers Pty Ltd All Rights Reserved. Copyright in the whole and every part of this
document belongs to Barlow Shelley Consulting Engineers Pty Ltd and may not be used, sold, transferred, copied or
reproduced in whole or in part in any manner or form or in or on any media to any person without the prior written consent
of Barlow Shelley Consulting Engineers Pty Ltd”

Page 3

EXECUTIVE SUMMARY

Barlow Shelley Consulting Engineers Pty Ltd has been commissioned by Stockwell Pty Ltd
to undertake a Site Based Stormwater Management Plan (SBSMP) for the proposed
subdivision development at Lot 3 on SP246584 Eenie Creek Road, Noosaville,
Queensland. An assessment of the stormwater quality requirements has been carried out
in accordance with the Noosa Council Planning Scheme 2017.


Stormwater quality improvement devices (SQIDs) are proposed to treat the road reserve,
which is greater than 2,500 m2, therefore pollutant reduction targets must be met as per
the Noosa Council Planning Scheme (2017) and Qld SPP (2017). A treatment train
consisting of bioretention systems and a vegetated swale are proposed to mitigate pollutant
load to meet the WSUD pollutant load reduction targets. The total bioretention filter area is
125m2 and the total swale length is 20m. The bioretention systems are situated in the road
reserve or proposed drainage reserve and will be designed in accordance with the WSUD
technical guidelines. When the individual lots created by this proposed subdivision are
developed, they will require SQIDs to satisfy stormwater runoff pollutant removal targets.

Page 4

CONTENTS



1.0    INTRODUCTION..................................................................................................... 1

2.0    SITE DESCRIPTION ............................................................................................... 2

3.0    PROPOSED DEVELOPMENT ................................................................................ 3

4.0    STORMWATER QUALITY MANAGEMENT ........................................................... 4
 4.1      CONSTRUCTION PHASE .................................................................................. 5
 4.2      OPERATIONAL PHASE ..................................................................................... 7
 4.3      MUSIC Modelling ............................................................................................. 10

5.0    CONCLUSION ...................................................................................................... 17

6.0    LIMITATIONS OF THIS REPORT......................................................................... 18

7.0    REFERENCES...................................................................................................... 19

8.0    CLOSURE ............................................................................................................ 20

Page 5

APPENDICES

APPENDIX A   -   Preliminary Plans by Barlow Shelley Consulting Engineers

APPENDIX B   -   Stormwater Quality Objectives – Construction Phase

Page 6

1.0 INTRODUCTION

Barlow Shelley Consulting Engineers Pty Ltd was commissioned by Stockwell Pty Ltd to
prepare a Site Based Stormwater Management Plan (SBSMP). The plan relates to the
proposed subdivision development located on Lot 3 on SP246584 Eenie Creek Road,
Noosaville, Queensland (Refer to Figure 1.1 – Locality map of the site).




                                             Lot 3 SP246584




                                         Figure 1.1 Locality map of site




Site Based Stormwater Management Plan                                      Page 1 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 7

2.0 SITE DESCRIPTION

The site is legally described as, Lot 3 on SP246584 Eenie Creek Road, Noosaville,
Queensland. It lies within the Local Government area of Noosa Council. Figure 2.1 below
shows the proximity of the site to Noosa Heads, and is approximately 5km to the South-
West of Noosa Heads.




                                                                                  Noosa Heads




                                                     Noosa Civic
                                                     Noosaville
                                                 Property boundary
                                                 Area = 31.7297 ha


                                  Figure 2.1 Aerial image of site in Noosaville



The site has a total area of 31.7297ha and is developed as Noosa Civic, and vegetated with
existing bushland. The site is zoned as Open Space Conservation and Shire Business
Centre (SBC). The site is surrounded by similar zoned properties.




Site Based Stormwater Management Plan                                                           Page 2 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 8

3.0 PROPOSED DEVELOPMENT

The proposed development consists of 25 lots. An internal road services the proposed lots.


The proposed development will comprise the construction and/or installation of the following
components for land use purposes:


  site earthworks and buildings (future)
  access driveway and car parks
  stormwater drains
  other ancillary services
  landscaping.


Once the development has been completed, all disturbed portions of the site will be
rehabilitated or covered by some form of protection against soil erosion and the
transportation of suspended solids from the site. These improvements will include
structures, paved areas and landscaping.




Site Based Stormwater Management Plan                                            Page 3 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 9

4.0 STORMWATER QUALITY MANAGEMENT

This Site Based Stormwater Management Plan includes Stormwater Quality Management
guidelines for the construction phase of the development. The development will implement
stormwater quality management for construction and operational phases as per Qld SPP
(2017), Council’s PSP, and the Water Sensitive Urban Design (WSUD) Technical Manual
by Healthy Waterways. The efficiency of the Stormwater Quality Improvement Devices
(SQID’s) during operational phase have been assessed with a MUSIC model as outlined in
Section 4.3 of this report. Refer to the Stormwater Management Layout in Appendix A
showing the catchment boundaries and treatment nodes proposed for the development.


The proposed allotments remain vacant as part of the subdivision development. Given the
proposed use of the allotments, development of each lot would trigger a Material Change
of Use application. Each future development shall provide its own SQID's to satisfy
stormwater runoff pollutant removal targets for the specific lot. The SQID's modelled with
this report are to address stormwater runoff from the road reserves only.




Site Based Stormwater Management Plan                                          Page 4 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 10

4.1 CONSTRUCTION PHASE

4.1.1 Pollutants

Typical pollutants generated during the construction phase of a development are listed in
Table 4.1 below.

  Pollutant                  Potential Source                                     Priority
  Litter                     Paper, construction packaging, food packaging,       High
                             cement bags, off cuts
  Sediment                   Unprotected exposed soils and stockpiles during      High
                             earthworks and building works
  Hydrocarbons               Fuel and oil spills, leaks from construction         High
                             equipment and temporary car park areas.
  Toxic Materials            Cement slurry, asphalt primer, solvents, cleaning    Medium
                             agents, wash waters (e.g. From tile works)
  Alkaline                   Cement slurry and wash waters                        High
  substances
                                Table 4.1 Typical Construction Phase Pollutants


4.1.2 Potential Impacts

Construction activities can have a potential impact on water quality. Removal of vegetation,
earthworks and changes to drainage patterns can result in erosion and sediment being
washed into waterways. This can impact on the physical-chemical parameters of the
receiving water, decline in the health of aquatic ecosystems, and overall aesthetics.
Potential impacts to the receiving waters surrounding the development site will be
minimized during the construction phase with typical measures as outlined below. These
measures should be adequately detailed on erosion and sediment control plans as part of
the development’s Operational Works application.


4.1.3 Performance Objectives

The amount of runoff traversing and discharging from the site while under construction
should be kept to a minimum. This will restrict soil erosion and mobilisation of sediments
and pollutants through and off the site.


Stormwater runoff at discharge points during the construction phase shall comply with the
objectives detailed in Table A in Appendix 2: Stormwater Management Design Objectives,
Part G, SPP (2017).

4.1.4 Control Measures

The following are typical treatment measures that should be implemented before the
commencement of any construction works. Detailed erosion and sediment control
procedures are to be based on the erosion and sediment control plans lodged at the
Operational Works phase.
Site Based Stormwater Management Plan                                              Page 5 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 11

Maintenance

Maintenance of erosion and control treatment measures (such as sediment fences) will be
undertaken if it is observed that they have not been properly installed or the capacity of the
measure falls below 75%.

Minimise Disturbed Areas

Only clear land which will be actively under construction in the near term (e.g. within the
next 3-6 months).

Stabilise Disturbed Areas

Provide temporary stabilisation of disturbed soils whenever active construction is not
occurring on a portion of the site. Provide permanent stabilisation during finish grade and
landscape the site.

Protect Slopes and Channels

Safely convey runoff from the top of the slope and stabilise temporary and permanent
channel crossings as quickly as possible and ensure that increases in runoff velocity caused
by the project do not erode the channel.

Diversions of Upslope Runoff

To prevent the contamination of clean runoff, upslope runoff should be diverted away from
areas of exposed soil. This may be achieved by installing tightly abutting sandbags, creating
a ‘sandbag perimeter bank’ to divert flow.

Sediment Fences and Inlet Protection

Delineate site perimeter to prevent disturbing areas outside the project limits. Sediment
fences should be installed around the perimeter of works to ensure contaminated runoff is
filtered and sediment is trapped before leaving the site. Sandbags or geofabric should also
be placed around/over existing stormwater inlets/grates throughout the site to ensure that
any contaminated runoff is filtered before it enters the existing piped stormwater network.

Retain Sediment

Retain sediment-laden waters from disturbed, active areas within the site.

Stabilised Vehicle Entry/Exit Point

To minimise the transport of sediment off site, a stabilised entry/exit point should be
constructed. All vehicles entering and leaving the site must use this designated entry/exit
point.

Site Based Stormwater Management Plan                                             Page 6 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 12

Stockpiles

Stockpile locations should be identified before the commencement of works. Ideally, they
should be located in a flat area at least 15m from any water body or stormwater inlet.
Sediment fences should be installed downslope of all erodible stockpiles, and upslope
protection measures should be used (i.e. sandbags or sediment fence) to divert runoff in
the event of rain. At the end of each working day stockpiles should be covered with geofabric
if rain or high winds are forecast.

Street Sweeping

Ensure that local roads are swept as required. This will minimise the potential for sediment
tracked onto the road to be washed into the stormwater system. If a large quantity of
sediment is being tracked onto the surrounding streets the stabilised entry/exit point may
need to be raked or reinforced with rock to provide more effective sediment removal for
vehicles.

Erosion Control Matting and Permanent Stabilisation

Exposed areas onsite should be permanently stabilised (i.e. with turf) as the construction
works progress. Erosion control matting or mulching should be used as a temporary
measure to stabilize exposed areas before permanent stabilisation can be undertaken.

Monitoring

Monitoring and recording of the performance of the drainage control devices including are
to be undertaken in accordance with local government requirements. It is further
recommended that the proposed construction works are undertaken during periods of dry
weather to reduce the potential for sediment to be transported off site during construction.



4.2 OPERATIONAL PHASE

The internal drainage system has been designed to include SQIDs in the water quality
treatment train for the proposed development. Refer to the conceptual drainage plans in
Appendix A for details.


4.2.1 Bioretention Basin

Bioretention basins are densely vegetated filtration devices, where runoff (for small/frequent
storm events) enters the basin and is filtered through a filter media layer (e.g. sandy loam)
as it percolates downwards. Bioretention basins often have an extended detention volume
above the filter media which increases the volume of runoff treated through the system.
The runoff is treated as it passes through the system through fine filtration, absorption, and
Site Based Stormwater Management Plan                                             Page 7 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 13

some biological uptake. Refer to Figure 4.1 below showing a typical cross section of a
bioretention basin.




                             Figure 4.1 Typical cross section of a bioretention basin


Bioretention provides a number of functions including:
      Reduce the velocity of runoff;
         Trap sediment and associated pollutants; and
         Reduce concentrations of nutrients such as Nitrogen and Phosphorous.


The detailed design, construction and maintenance of bioretention basins should be in
accordance with the ‘WSUD Technical Design Guidelines’. Plant species for bioretention
basins within this development should be selected based on WSUD Technical Design
Guidelines, and the integration with the landscape design.


Establishing Bioretention Basins
The establishment period for plant species before the vegetation is mature and fully
functional is typically two years. During this period, regular site maintenance and monitoring
is crucial to the success of the basin as a treatment device




4.2.2 Bioretention Street Tree (Tree Pit)

Bioretention Street Trees are a combination of a bioretention system and a street tree. They
are typically designed to be small systems able to accommodate trees suitable for use in
streetscapes and shrubs for additional nutrient uptake and aesthetics.




Site Based Stormwater Management Plan                                                   Page 8 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 14

      Figure 4.2 Typical cross section of a bioretention street tree (Source IPWEA standard drawing DS-077)




Site Based Stormwater Management Plan                                                              Page 9 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 15

4.3 MUSIC Modelling

MUSIC (Version 6.2, eWater), a pollutant export modelling program has been used to model
both the expected pollutant loads generated by the development and the effectiveness of
WSUD treatment options selected.

4.3.1 Split Catchment Approach

The MUSIC model is based on a split catchment approach, modeled as various catchments
representing the different surface types in accordance with the guidelines and available site
information. Split catchment surface information can be found in Table 4.2 below (taken
from the guidelines).

                             Surface Type                     % Imperviousness
                             Road Reserve                              60%
                                     Table 4.2 Adopted % Imperviousness


Table 4.3 lists the total areas for the surface type in the catchment that was used in the
model. The total area is the proposed total extent of the road reserve area.


                           Node                                              Area (ha)
               West Hofmann Drive C1                                         0.1150

               West Hofmann Drive C2                                         0.2545

               West Hofmann Drive C3                                         0.1250

                         Road A                                              0.2265

                    Road A Bypass                                            0.0270

                         Road B                                              0.4070

                Driveway and Reserve                                         0.2270

                           Total                                             1.3820
                                         Table 4.3 Surface Area of Nodes




4.3.2 MUSIC Meteorological Data

Cooroy DPI (Station 40059) meteorological data was selected for the MUSIC analysis. The
10-year climate period was selected in accordance with Table 3.1 of the guidelines. The
rainfall and evapo-transpiration data for the period of 01/01/1973 to 31/12/1983, with a 6-
minute time step was used in the model.




Site Based Stormwater Management Plan                                                    Page 10 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 16

Input parameters for the rainfall-runoff, source nodes and treatment devices were also
obtained from the guidelines. The following parameters were selected based on a
commercial/industrial development.



4.3.3 Rainfall-Runoff Parameters

The rainfall-runoff parameters listed in Table 3.7 of MUSIC guidelines were used in the
model. The parameters recommended by the guideline are as shown in Table 4.4 below.


         PARAMETER                                                    Commercial/Industrial
         Rainfall threshold (mm)                                               1
         Soil storage capacity (mm)                                          18
         Initial storage (% capacity)                                         10
         Field capacity (mm)                                                 80
         Infiltration capacity                                               243
         Coefficient a
         Infiltration capacity                                                     0.6
         Exponent b
         Initial depth (mm)                                                        50
         Daily recharge rate (%)                                                    0
         Daily baseflow rate (%)                                                   31
         Daily deep seepage rate (%)                                                0
                               Table 4.4 Recommended rainfall-runoff parameters




4.3.4 MUSIC Pollutant Export Parameters Split Catchment Land Use (Industrial)

                                     TSS log10
                                                            TP log10 values         TN log10 values
                   Surface             values
 Flow Type
                    Type                      St.                          St.                    St.
                                   Mean                     Mean                      Mean
                                            dev.                          dev.                   dev.
 Baseflow             Roof          N/A      N/A             N/A          N/A            N/A     N/A
 parameters
                    Roads           0.78        0.45        -1.11         0.48           0.14    0.20
                    Ground          0.78        0.45        -1.11         0.48           0.14    0.20
                     Level
 Stormflow           Roof           1.30        0.44        -0.89         0.36           0.25    0.32
 Parameters
                    Roads           2.43        0.44        -0.30         0.36           0.25    0.32
                    Ground          1.92        0.44        -0.59         0.36           0.25    0.32
                     Level
                    Table 4.5 MUSIC Export Parameters Split Catchment Land Use (Industrial)




Site Based Stormwater Management Plan                                                           Page 11 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 17

4.3.5 MUSIC Treatment Node Parameters (Post Developed Site)

Bioretention Basins


Figure 4.3 and Figure 4.5 show the parameters for the bioretention basins.




                 Figure 4.3 Bioretention node parameters Street Tree Pit West Hofmann Drive C1




                        Figure 4.4 Bioretention node parameters West Hofmann Drive C2




Site Based Stormwater Management Plan                                                            Page 12 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 18

                        Figure 4.5 Bioretention node parameters West Hofmann Drive C3




                                Figure 4.6 Bioretention node parameters Road A




Site Based Stormwater Management Plan                                                   Page 13 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 19

                        Figure 4.7 Bioretention node parameters Street Tree Pits Road B




                         Figure 4.8 Bioretention node parameters Driveway and Reserve




Site Based Stormwater Management Plan                                                     Page 14 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 20

Vegetated Swale

Figure 4.9 shows the parameters for the vegetated swale node in the MUSIC model.




                                  Figure 4.9 Vegetated Swale Node Parameters




Site Based Stormwater Management Plan                                          Page 15 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 21

4.3.6 MUSIC Model Results

Figure 4.10 shows the MUSIC model treatment train layout and results from the proposed
stormwater quality improvement devices (SQIDs), which is also shown on drawings
1856/SW01-SW05 in Appendix A. The results as shown below were generated using the
stochastic option as per the guidelines.




                                         Figure 4.10 MUSIC Model Results


All load-based pollutant reduction efficiencies are met in accordance with the Table A in
Appendix 2: Stormwater Management Design Objectives, Part G, SPP (2017) included in
Appendix B.
Site Based Stormwater Management Plan                                         Page 16 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 22

5.0 CONCLUSION

This site-based stormwater management plan has reviewed the stormwater quality
management at the proposed development at Noosaville, Queensland.


Based on this assessment the following conclusions have been made:


 The proposed development includes Stormwater Quality Improvement Devices being
   bioretention basins and vegetated swales treating post-developed flows from the
   proposed road reserve only, in accordance with the Qld SPP (2017). The total amount
   of treatment devices are as follows:
         o   Vegetated swale (total length) = 20m
         o   Bioretention basin (total area) = 125m2


   In the event the individual lots created by this subdivision are developed, they will require
   SQIDs to satisfy stormwater runoff pollutant removal targets for each specific lot.

In summary, stormwater leaving the site will satisfy the pollutant removal criteria in Council’s
Planning Scheme and the Qld SPP.




Site Based Stormwater Management Plan                                               Page 17 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 23

6.0      LIMITATIONS OF THIS REPORT

This Site Based Stormwater Management Plan (SBSMP) has been tailored to report on
issues in the areas of interest, as detailed above. The information in this report is not to be
used outside of the subject area.


We consider that this SBSMP accurately considers conditions at the area of interest at the
time the SBSMP was developed and based on information supplied to us by second and
third parties. This SBSMP is to be reviewed, if site conditions change in the future.


This SBSMP has been undertaken for the specific purposes of the Stockwell Pty Ltd, as
detailed in our correspondence to them, and is solely for their use.


This SBSMP should only be used in full and may not be used to support objectives other
than those set out herein, except where written approval, with comments, are provided by
Barlow Shelley Consulting Engineers.


Barlow Shelley Consulting Engineers accept no liability with respect to the accuracy of
information supplied by second and third parties.




Site Based Stormwater Management Plan                                              Page 18 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 24

7.0 REFERENCES


Department of Infrastructure, Local Government and Planning (July 2017), State Planning
Policy, DILGP, Brisbane.


Institute of Public Works Engineering Australasia, Queensland (2017), Queensland Urban
Drainage Manual – Fourth Edition, IPWEAQ, Queensland.


Water by Design (2014). Bioretention Technical Design Guidelines (Version 1.1). Healthy
Waterways Ltd, Brisbane.




Site Based Stormwater Management Plan                                        Page 19 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 25

8.0      CLOSURE

Should further information be required please contact:


AUTHORED BY:




_______________________________
VINCENT VICIC – ENGINEER
BEng GradIEAust
For and on behalf of:
BARLOW SHELLEY CONSULTING ENGINEERS (AUST) PTY LTD



REVIEWED & APPROVED BY:



_________________________________________
CAMERON LANDRETH – DIRECTOR (RPEQ 19358)
BEng (Hons), NER, RPEQ
For and on behalf of:
BARLOW SHELLEY CONSULTING ENGINEERS (AUST) PTY LTD




Site Based Stormwater Management Plan                    Page 20 of 20
1856-SBSMP-01_Version 2.0 (April 2019)

Page 26

                                                         Appendix




Preliminary Plans by Barlow Shelley Consulting Engineers

   -   Drawings 1856/SW01-SW05
       Prepared by Barlow Shelley Consulting Engineers

Page 27

                                                                                   RIVE
                                                                   ANN D
                                                               HOFM                                                                                                                RO                                                                                                                                                 E
                                                                                                                                                                                     AD
                                                                                                                                                                                                            SWALE 20m            BIO-RETENTION                                                                                      IV
                                                                                                                                                                                                                                                                                                                                   R
                                                                                                                                                                                          A                                      BASIN 20m²                                                                                       D
                                                                                                                                                                                                                                                                                                                              Y
                                                                                                                                                                                                                                                                                                                             A
                                                                                                                                                                                                                                                                                                                         H
                                                                                                                                                                                                                                                                                                                    ER
                                                                                                                                                                                                                                                                                                                  LT
                                                                                                                                                                                                                                                                                                                A
                                                                                                                                                                                                                                                                                                              W
                  ROAD B
TREE PITS 15m²             TREE PITS 15m²

                                               LOT 16
                                               4525m²




                                                                                                    B
                                                                                               AD
                                                                                             RO
                                                                                                                                                            LOT 10
                                                                                                                                                            4733m²


                                                                                                                                                                                                                                                            EXISTING
                                                                                                                                                                                                                                                            ROUNDABOUT




                 LOT 13
                                                                                              LOT 11
                 4117m²
                                                                                              4999m²




                                            LOT 12
                                            7972m²


                                                                                                                                                                                                                  E
                                                                                                                                                                                                                IV
                                                                                                                                                                                                             R
                                                                                                                                                                                                            D
                                                                                                                                                                                                        Y
                                                                                                                                                                                                    A
                                                                                                                                                                                                   H
                                                                                                                                                                                              ER
                                                                                                                                                                                          LT
                                                                                                                                                                                     A
                                                                                                                                                                                    W




                                                                                                                                                                                                                                                                                                  LEGEND - EXISTING SERVICES
                                                                                                                                                                                                                                                                                                                         EXISTING SEWER DN225 uPVC SN8
                                                                                                                                                                                                                                                                                                                         EXISTING SEWER DN150 uPVC SN8
                                                                                                                                                                                                                                                                                                                         EXISTING DN150 OPVC PN16 WATERMAIN
                                                                                                                                                                                                                                                                                                                         EXISTING DN250 DI PN35 WATERMAIN
                                                                                                                                                                                                                                                                                                                         EXISTING DN610 WATERMAIN

                                                                                                                                                                                                                                                                                                  LEGEND - NEW WORKS EXTENT

                                                                                                                                                                                                                                                                                                                         EXTENT OF AC SEAL


                                                                                                                                                                                                                                                                                                                         EXTENT OF CUT EARTHWORKS

                                                                                                                                                                                                                                                                                                                         KERB & CHANNEL (B1 TYPE 450mm CHANNEL)

                                                                                                                                                                                                                                                                                                                         EXTENT OF 2m WIDE CONCRETE FOOTPATH


                                                                                                                                                                                                                                                                                                                         EXTENT OF COMMERICAL DRIVEWAY
                                                                                              E
                                                                                             RIV




                                                                                                                                                                                                                                                                                                                         ROAD CENTRELINE
                                                                                      YD




                                                                                                                                                                                                                                                                                                                         STORMWATER DRAINAGE
                                                                                    HA
                                                                                  R




                                                                                                                                                                                                                                                                                 PROJECT:                                                            JOB NUMBER
                                                                                 TE




REV DATE DESCRIPTION             BY    CHKD DRAWN
                                                I GDETAL
                                                       IS                                             SCALE                                                      APPROVED                                                                                                        PROPOSED SUBDIVISION                                                    1856
                                                                              AL




                                                                                                                                                                                                                                                                                 AT WALTER HAY DRIVE, NOOSAVILLE
                                                                             W




                                              DATUM           AHD                                                                                                                                                                                                                                                                               SHEET:        OF
                                              DESIGN          MM
                                                                         0              10             20             30              40              50m      .................                                                                                                 FOR STOCKWELL PTY LTD
                                                                                                                                                                                                                                                                                                                                                          1        7


                                                                                                                                                            Director: CAMERON LANDRETH                                                                                           DRAWING TITLE:                                                 DRAWING NUMBER         REV
                                              DRAWN           MM
                                                                                                                                                                      (RPEQ 19358)
                                                                                                    SCALE 1:1000 A3                                                                                                   p 07 5443 8285                                             STORMWATER LAYOUT PLAN 1 OF 6
                                              DESIGN CHECK     CL
                                                                                                                                                            DRAWING STATUS                                            e [email protected] w www.barlowshelley.com.au
                                                                                                                                                                                                                                                                                                                                                    SW01
                                                                        This drawing is not to be copied or amended without written permission from
                                              DATE           21-02-19                                                                                             FOR APPROVAL                                        a PO Box 899, Maroochydore,4558 ABN 89 215 591 077
                                                                        Barlow Shelley Consulting Engineers

Page 28

                                                                                             BIO-RETENTION
                                                                                             BASIN 30m²


                 BIO-RETENTION                                                                  LOT 4
                     BASIN 20m²                                                                 2365m²




                                                 HO
                                                   FM
                                                      AN
                                                          N
                                                           DR
                                                             IV
                                                                E
                                                                                                                                                LOT 5                                                 BIO-RETENTION
                                                                                                                                                2307m²                                                    BASIN 20m²



                                                                                                                                                                                           LOT 6                                                                                                                               LOT 8
                                                                                                                                                                                           2473m²                                                                                                                              3257m²




                                       LOT 15
                                       4247m²                                                                                                                                                                                                                                                LOT 9
                                                                                                                                                                                                                                                                                             3274m²




                                                                                                                                                                                                  RIVE
                                                                                                                                                                                           ANN D
                                                                                                                                                                                    HOFM                                                                                          RO
                                         TREE PITS 15m²                                                                                                                                                                                                                                AD
                                                                                                                                                                                                                                                                                            A
                                                                                                                                TREE PITS 5m²
                                                                            ROAD B




                                                                                                                           TREE PITS 15m²

                                                                                                                                                               LOT 16
                                                                                                                                                               4525m²

                                       LOT 14
                                       4005m²




                                                                                                                                                                                                              B
                                                                                                                                                                                                           AD
                                                                                                                                                                                                         RO
                                                                                                                                                                                                                                                 LOT 10
                                                                                                                                                                                                                                                 4733m²

                                                                                                                                                                                                                                                                                                                         LEGEND - EXISTING SERVICES
                                                                                                                                                                                                                                                                                                                                        EXISTING
                                                                                                                                                                                                                                                                                                                                            EXISTING SEWER DN225 uPVC SN8
                                                                                                                                                                                                                                                                                                                                        ROUNDABOUT
                                                                                                                                                                                                                                                                                                                                            EXISTING SEWER DN150 uPVC SN8
                                                                                                                                                                                                                                                                                                                                            EXISTING DN150 OPVC PN16 WATERMAIN
                                                                                                                                                                                                                                                                                                                                            EXISTING DN250 DI PN35 WATERMAIN
                                                                                                                                                                                                                                                                                                                                            EXISTING DN610 WATERMAIN

                                                                           LOT 13                                                                                                                                                                                                                                        LEGEND - NEW WORKS EXTENT
                                                                                                                                                                                                          LOT 11
                                                                           4117m²
                                                                                                                                                                                                          4999m²
                                                                                                                                                                                                                                                                                                                                            EXTENT OF AC SEAL


                                                                                                                                                                                                                                                                                                                                            EXTENT OF CUT EARTHWORKS
                                                                                                                                                        LOT 12
                                                                                                                                                                                                                                                                                                                                            KERB & CHANNEL (B1 TYPE 450mm CHANNEL)
                                                                                                                                                        7972m²

                                                                                                                                                                                                                                                                                                                                            EXTENT OF 2m WIDE CONCRETE FOOTPATH
                                                                                                                                                                                                                                                                                                                     E
                                                                                                                                                                                                                                                                                                                   IV
                                                                                                                                                                                                                                                                                                               R
                                                                                                                                                                                                                                                                                                              D
                                                                                                                                                                                                                                                                                                          Y                                 EXTENT OF COMMERICAL DRIVEWAY
                                                                                                                                                                                                                                                                                                         A
                                                                                                                                                                                                                                                                                                     H
                                                                                                                                                                                                                                                                                                ER
                                                                                                                                                                                                                                                                                            LT                                              ROAD CENTRELINE
                                                                                                                                                                                                                                                                                        A
                                                                                                                                                                                                                                                                                   W                                                        STORMWATER DRAINAGE

                                                                                                                                                                                                                                                                                        PROJECT:                                                                        JOB NUMBER
REV DATE DESCRIPTION              BY   CHKD DRAWN
                                                I GDETAL
                                                       IS                                                          SCALE                                                      APPROVED                                                                                                 PROPOSED SUBDIVISION                                                                 1856
                                                                                                                                                                                                                                                                                       AT WALTER HAY DRIVE, NOOSAVILLE
                                             DATUM                   AHD                                                                                                                                                                                                                                                                                           SHEET:        OF
                                             DESIGN                  MM
                                                                                      0              10             20             30              40              50m      .................                                                                                          FOR STOCKWELL PTY LTD
                                                                                                                                                                                                                                                                                                                                                                             2        7


                                                                                                                                                                         Director: CAMERON LANDRETH                                                                                     DRAWING TITLE:                                                             DRAWING NUMBER         REV
                                             DRAWN                   MM
                                                                                                                                                                                   (RPEQ 19358)
                                                                                                                 SCALE 1:1000 A3                                                                                       p 07 5443 8285                                                  STORMWATER LAYOUT PLAN 2 OF 6
                                             DESIGN CHECK             CL
                                                                                                                                                                         DRAWING STATUS                                e [email protected] w www.barlowshelley.com.au
                                                                                                                                                                                                                                                                                                                                                                       SW02
                                                                                     This drawing is not to be copied or amended without written permission from
                                             DATE                   21-02-19                                                                                                   FOR APPROVAL                            a PO Box 899, Maroochydore,4558 ABN 89 215 591 077
                                                                                     Barlow Shelley Consulting Engineers

Page 29

                                                HO
                                                  FM
                                                                                                     LOT 21
                                                                                                     4288m²




                                                    AN
                                                       N
                                                         DR
                                                           IV
                                                              E
                                                                    FH




                                                                                                                                         LOT 20
                                                                                                                                         2149m²




                                                                                                                                                                        LOT 19
                                                                                                                                                                        2235m²




                                                                                                                                                                                          LOT 18
                                                                                                                                                                                          2542m²




                                                                                                                                                                                                                         LOT 17
                                                                                                                                                                                                                         2716m²
 LEGEND - EXISTING SERVICES
                       EXISTING SEWER DN225 uPVC SN8
                       EXISTING SEWER DN150 uPVC SN8
                       EXISTING DN150 OPVC PN16 WATERMAIN
                       EXISTING DN250 DI PN35 WATERMAIN
                       EXISTING DN610 WATERMAIN                                                                                                                                               H
                                                                                                                                                                                               O
                                                                                                                                                                                                  FM
 LEGEND - NEW WORKS EXTENT                                                                                                                                                                             A
                                                                                                                                                                                                        N
                                                                                                                                                                                                         N
                                                                                                                                                                                                             D
                       EXTENT OF AC SEAL                                                                                                                                                                      R
                                                                                                                                                                                                               IV
                                                                                                                                                                                                                    E

                       EXTENT OF CUT EARTHWORKS

                       KERB & CHANNEL (B1 TYPE 450mm CHANNEL)

                       EXTENT OF 2m WIDE CONCRETE FOOTPATH


                       EXTENT OF COMMERICAL DRIVEWAY                                                                                                                                                                                60
                                                                                                                                                                                                                               3.
                                                                                                                                                                                                                             S
                                                                                                                                                                                                                            N
                       ROAD CENTRELINE
                       STORMWATER DRAINAGE
                                                                                                                                                                                                                                                                                   LOT 4
                                                                                                                                                                                                                                                                                   2365m²
                                                                                                                                                                                                                                         HO




                                                                                                                                                                                                                                                                                      PROJECT:                              JOB NUMBER
                                                                                                                                                                                                                                            F




REV DATE DESCRIPTION                BY     CHKD DRAWN
                                                    I GDETAL
                                                           IS                                              SCALE                                                      APPROVED
                                                                                                                                                                                                                                            M




                                                                                                                                                                                                                                                                                      PROPOSED SUBDIVISION                       1856
                                                                                                                                                                                                                                              AN




                                                                                                                                                                                                                                                                                      AT WALTER HAY DRIVE, NOOSAVILLE
                                                                                                                                                                                                                                                 N




                                                DATUM              AHD                                                                                                                                                                                                                                                  SHEET:        OF
                                                                                                                                                                    .................                                                                                                                                             3        6
                                                                                                                                                                                                                                                   DR




                                                DESIGN             MM
                                                                              0              10             20             30              40              50m                                                                                                                        FOR STOCKWELL PTY LTD
                                                                                                                                                                                                                                                     IV




                                                                                                                                                                                                                                                                                                                        DRAWING NUMBER         REV
                                                                                                                                                                                                                                                        E




                                                                                                                                                                 Director: CAMERON LANDRETH                                                                                           DRAWING TITLE:
                                                DRAWN              MM
                                                                                                                                                                           (RPEQ 19358)
                                                                                                         SCALE 1:1000 A3                                                                                                p 07 5443 8285                                                STORMWATER LAYOUT PLAN 3 OF 6
                                                DESIGN CHECK        CL
                                                                                                                                                                 DRAWING STATUS                                         e [email protected] w www.barlowshelley.com.au
                                                                                                                                                                                                                                                                                                                         SW03
                                                                             This drawing is not to be copied or amended without written permission from
                                                DATE              21-02-19                                                                                             FOR APPROVAL                                     a PO Box 899, Maroochydore,4558 ABN 89 215 591 077
                                                                             Barlow Shelley Consulting Engineers

Page 30

                                                                                                                                                                   EE
                                                                                                                                                                     NI
                                                                                                                                                                        E
                                                                                                                                                                            CR
                                                                                                                                                                              EE
                                                                                                                                                                                K
                                                                                                                                                                                    RO
                                                                                                                                                                                       AD




                                                  U
                                                                                                                          LOT 2




                                                   N
                                                    -N
                                                                                                                          9550m²




                                                        AM
                                                            ED
                                                             R
                                                              O
                                                                     AD




                                                                                                                                                                                                                          EXISTING
                                                                                                                                                                                                                          ROUNDABOUT




                                                                                                                                                                    D
                                                                                                                                                                  OA
                                                                                                                                                            DR
                                                                                                                                                        ME
                                                                                                                                                     -NA
                                                                                                                                                  UN



                                                                                                                                                                                                                                                                         LEGEND - EXISTING SERVICES
                                                                                                                                                                                                                                                                                          EXISTING SEWER DN225 uPVC SN8
                                                                                                                                                                                                                                                                                          EXISTING SEWER DN150 uPVC SN8
                                                                                                                                                                                                                                                                                          EXISTING DN150 OPVC PN16 WATERMAIN
                                                                                                                                                                                                                                                                                          EXISTING DN250 DI PN35 WATERMAIN
                                                                                                                                                                                                                                                                                          EXISTING DN610 WATERMAIN

                                                                                                                                                                                                                                                                         LEGEND - NEW WORKS EXTENT




                                                                                                                                                                                                                                                             RIVE
                                                                                                                                                                                                                                                          HAY D
                                                                                                                                                                                                                                                                                          EXTENT OF AC SEAL




                                                                                                                                                                                                                                                            ER
                                                                                                                                                                                                                                                                                          EXTENT OF CUT EARTHWORKS




                                                                                                                                                                                                                                                       WALT
                                                                                                                                                                                                                                                                                          KERB & CHANNEL (B1 TYPE 450mm CHANNEL)

                                                                                                                                                                                                                                                                                          EXTENT OF 2m WIDE CONCRETE FOOTPATH


                                                                                                                                                                                                                                                                                          EXTENT OF COMMERICAL DRIVEWAY

                                                                                                                                                                                                                                                                                          ROAD CENTRELINE
                                                                                                                                                                                                                                                                                          STORMWATER DRAINAGE
                                                                                                                                                                                                                                                        PROJECT:                                                      JOB NUMBER
REV DATE DESCRIPTION   BY   CHKD DRAWN
                                     I GDETAL
                                            IS                                             SCALE                                                      APPROVED                                                                                         PROPOSED SUBDIVISION                                                1856
                                                                                                                                                                                                                                                       AT WALTER HAY DRIVE, NOOSAVILLE
                                 DATUM            AHD                                                                                                                                                                                                                                                             SHEET:        OF
                                 DESIGN           MM
                                                                 0           10             20             30              40              50m      .................                                                                                  FOR STOCKWELL PTY LTD
                                                                                                                                                                                                                                                                                                                            4        6


                                                                                                                                                 Director: CAMERON LANDRETH                                                                             DRAWING TITLE:                                           DRAWING NUMBER          REV
                                 DRAWN            MM
                                                                                                                                                           (RPEQ 19358)
                                                                                         SCALE 1:1000 A3                                                                                    p 07 5443 8285                                             STORMWATER LAYOUT PLAN 4 OF 6
                                 DESIGN CHECK      CL
                                                                                                                                                 DRAWING STATUS                             e [email protected] w www.barlowshelley.com.au
                                                                                                                                                                                                                                                                                                                     SW04
                                                             This drawing is not to be copied or amended without written permission from
                                 DATE            21-02-19                                                                                              FOR APPROVAL                         a PO Box 899, Maroochydore,4558 ABN 89 215 591 077
                                                             Barlow Shelley Consulting Engineers

Page 31

K
    RO
      AD




                                                                                          LOT 23
                                                                                          5055m²




                                                                                                                                                                                               LOT 24
                                                                                                                                                                                               6079m²




                                                                                                                                                                                                                                                                   LOT 25
                                                                                                                                                                                                                                                                   1.497 Ha




                                                                                                                                                                      EE
                                                                                                                                                                        NI
                                                                                                                                                                          E
                                                                                                                                                                              CR
                                                                                                                                                                                EE
                                                                                                                                                                                   K
                                                                                                                                                                                       RO
                                                                                                                                                                                          AD




                                                                                                                                                                                                                                                                                      LEGEND - EXISTING SERVICES
                                                                                                                                                                                                                                                                                                       EXISTING SEWER DN225 uPVC SN8
                                                                                                                                                                                                                                                                                                       EXISTING SEWER DN150 uPVC SN8
                                                                                                                                                                                                                                                                                                       EXISTING DN150 OPVC PN16 WATERMAIN
                                                     U




                                                                                                                       LOT 2                                                                                                                                                                           EXISTING DN250 DI PN35 WATERMAIN
                                                      N
                                                         -N




                                                                                                                       9550m²
                                                                                                                                                                                                                                                                                                       EXISTING DN610 WATERMAIN
                                                           AM
                                                              ED




                                                                                                                                                                                                                                                                                      LEGEND - NEW WORKS EXTENT
                                                                R
                                                                   O
                                                                    AD




                                                                                                                                                                                                                                                                                                       EXTENT OF AC SEAL


                                                                                                                                                                                                                                                                                                       EXTENT OF CUT EARTHWORKS

                                                                                                                                                                                                                                                                                                       KERB & CHANNEL (B1 TYPE 450mm CHANNEL)

                                                                                                                                                                                                                                                                                                       EXTENT OF 2m WIDE CONCRETE FOOTPATH


                                                                                                                                                                                                                                                                                                       EXTENT OF COMMERICAL DRIVEWAY

                                                                                                                                                                                                                                                                                                       ROAD CENTRELINE
                                                                                                                                                                                                                          EXISTING
                                                                                                                                                                                                                          ROUNDABOUT                                                                   STORMWATER DRAINAGE
                                                                                                                                                                                                                                                                     PROJECT:                                                     JOB NUMBER
           REV DATE DESCRIPTION   BY   CHKD DRAWN
                                                I GDETAL
                                                       IS                                              SCALE                                                      APPROVED                                                                                          PROPOSED SUBDIVISION                                              1856
                                                                                                                                                                                                                                                                    AT WALTER HAY DRIVE, NOOSAVILLE
                                            DATUM               AHD                                                                                                                                                                                                                                                          SHEET:        OF
                                            DESIGN              MM
                                                                          0              10             20             30              40              50m      .................                                                                                   FOR STOCKWELL PTY LTD
                                                                                                                                                                                                                                                                                                                                       5        6


                                                                                                                                                             Director: CAMERON LANDRETH                                                                              DRAWING TITLE:                                          DRAWING NUMBER         REV
                                            DRAWN               MM
                                                                                                                                                                       (RPEQ 19358)
                                                                                                     SCALE 1:1000 A3                                                                                    p 07 5443 8285                                              STORMWATER LAYOUT PLAN 5 OF 6
                                            DESIGN CHECK        CL
                                                                                                                                                             DRAWING STATUS                             e [email protected] w www.barlowshelley.com.au
                                                                                                                                                                                                                                                                                                                               SW05
                                                                         This drawing is not to be copied or amended without written permission from
                                            DATE              21-02-19                                                                                             FOR APPROVAL                         a PO Box 899, Maroochydore,4558 ABN 89 215 591 077
                                                                         Barlow Shelley Consulting Engineers

Page 32

                                                    EE
                                                      NI
                                                           E
                                                               CR
                                                                 EE
                                                                      K
                                                                           RO
                                                                             AD




                                                                                                                                                                                                                                                                              EE
                                                                                                                                   LOT 22                                                                                                                                       NI
                                                                                                                                                                                                                                                                                  E
                                                                                                                                   3827m²                                                                                                                                             CR
                                                                                                                                                                                                                                                                                           EE
                                                                                                                                                                                                                                                                                              K
                                                                                                                                                                                                                                                                                                  RO
                                                                                                                                                                                                                                                                                                    AD



                              DRIVE


                         NN
                     FMA                                                                                                                                                               NEW SEWER CONNECTION FROM
                  HO                                                                                                                                                                   EXISTING SEWER MANHOLE



       N   N
    MA                                                                               PRE-TAP CONNECTION
HOF                                                                                  FROM EXISTING DN250
                                                                                    WATERMAIN FOR LOT 22

                                                                                                                                                                                                                                                                                                         LEGEND - EXISTING SERVICES
                                                                                                                                               UN                                                                                                                                                                         EXISTING SEWER DN225 uPVC SN8
                                                                                                                                                     -N                                                                                                                                                                   EXISTING SEWER DN150 uPVC SN8
                                                                                                                                                         AM
                                                                                                                                                                ED                                                                                                                                                        EXISTING DN150 OPVC PN16 WATERMAIN
                                                                                                                                                                      RO
                                                                                                                                                                         AD                                                                                                                                               EXISTING DN250 DI PN35 WATERMAIN
                                                                                                                                                                                                                                                                                                                          EXISTING DN610 WATERMAIN

                                                                                                                                                                                                                                                                                                         LEGEND - NEW WORKS EXTENT

                                                                                                                                                                                                                                                                                                                          EXTENT OF AC SEAL


                                                                                                                                                                                                                                                                                                                          EXTENT OF CUT EARTHWORKS

                                                                                                                                                                                                                                                                                                                          KERB & CHANNEL (B1 TYPE 450mm CHANNEL)

                                                                                                                                                                                                                                                                                                                          EXTENT OF 2m WIDE CONCRETE FOOTPATH


                                                                                                                                                                                                                                                                                                                          EXTENT OF COMMERICAL DRIVEWAY

                                                                                                                                                                                                                                                                                                                          ROAD CENTRELINE
                                                                                                                                                                                                                                                                                                                          STORMWATER DRAINAGE

                                                                                                                                                                                                                                                                                 PROJECT:                                                             JOB NUMBER
       REV DATE DESCRIPTION    BY     CHKD DRAWN
                                               I GDETAL
                                                      IS                                                        SCALE                                                         APPROVED                                                                                          PROPOSED SUBDIVISION                                                      1856
                                                                                                                                                                                                                                                                                AT WALTER HAY DRIVE, NOOSAVILLE
                                           DATUM                     AHD                                                                                                                                                                                                                                                                         SHEET:        OF
                                           DESIGN                    MM
                                                                                   0              10             20             30              40              50m      .................                                                                                      FOR STOCKWELL PTY LTD
                                                                                                                                                                                                                                                                                                                                                           6        6


                                                                                                                                                                      Director: CAMERON LANDRETH                                                                                 DRAWING TITLE:                                                  DRAWING NUMBER         REV
                                           DRAWN                     MM
                                                                                                                                                                                (RPEQ 19358)
                                                                                                              SCALE 1:1000 A3                                                                                      p 07 5443 8285                                                STORMWATER LAYOUT PLAN 6 OF 6
                                           DESIGN CHECK               CL
                                                                                                                                                                      DRAWING STATUS                               e [email protected] w www.barlowshelley.com.au
                                                                                                                                                                                                                                                                                                                                                     SW06
                                                                                  This drawing is not to be copied or amended without written permission from
                                           DATE                     21-02-19                                                                                                  FOR APPROVAL                         a PO Box 899, Maroochydore,4558 ABN 89 215 591 077
                                                                                  Barlow Shelley Consulting Engineers

Page 33

                                                        1.5m                     2.0m                                 1.0m


                                                                                                                                                                                                                                                                               TEMPORARY TURF
                                                                                                            RL = + 500MM FROM
                                                                                                            FILTER MATERIAL


                                                                                                                                                                                                                                                         50mm TOP SOIL




                                                                                                 0.300
                                                                                                  MIN
                                           1:3
                                                                                                                                     1:2
                                                                                                                                                                                                                                                         GOETEXTILE FABRIC
                                                                                                                                                                                                                                                         WRAPPED OVER COMPLETE
                                                                                                                                                                                                                                                         FILTER MEDIA

                                  TEMPORARY TURF OVER 50mm SOIL                                                                                                                                                                                          BIORETENTION BASIN
                                  AND GOETEXTILE LAYER' REFER TO                                                FUTURE MACROPHYTE PLANTING                                                                                                               REFER TO TYPICAL
                                  DETAIL A                                                                      TO SUIT GROUND CONDITIONS                                                                                                                CROSS SECTION.
                                                                                                                WITH MULCH LAYER (REFER
                                                                                                                LANDSCAPING DRAWINGS)
                                            100Ø SUBSOIL
                                             DRAINAGE PIPES
                                                                                                                                                                                                                                                                                BIORETENTION DETAIL
                                                         POLY LINER                                                                                                                                                                                                             NOT TO SCALE




                                                       BIO-RETENTION - TYPICAL SECTION
                                                                                         NOT TO SCALE


                                                                                                                                                                                                                                                                                                        FIELD INLET PIT TYPE 1
                                                                                                                                                                                                                            FILTER CLOTH OR ORGANIC GEOTEXTILE MATTING FIXED TO                         WITHOUT CONCRETE
                                                                                                                                                                                                                            PERIMETER OF WALLS TO AVOID RUNNELLING OF WATER                             APRON (IPWEA STD DWG
                                                                                                                                                     PROPOSED EDGE                                                                                                                                      D-0050
                                                                                                                                                     RESTRAINT (ER2 TYPE)                                                   BETWEEN PIT AND SOIL INTERFACE. 300 WIDE, 100 COVER.                                    OVERFLOW PIT 300mm
                                                                                                                                                                                                                                                             FUTURE PLANTING TO                                     ABOVE BIORETENTION FSL
                                                                                                                                                                                                                            C.I. CAP TO EXTEND
                                                                                                                                                                                                                            APPROX. 150mm ABOVE              LANDSCAPE PLANS                                         MEDIA LEVEL     TEMPORARY TURF
                                                                                                                                                                                                                            BASIN SURFACE                                                                                            AND TOP SOIL



                       3%>                                                                                                                                              <3%
                                                                                                                                                                                                                     BIORETENTION 600




                                                                                                                                                                                                                                                                                                100
                                                 1:4                                                                                                                                                                 FILTER MEDIA
                                                                                                                1:4

                                                                                                                                                                                                                     COARSE SAND 100
                                                                                                                                                                                                                     5-10mm GRAVEL 200

                                                                                                                                                                                                                                                                    Ø100 - Ø150 SLOTTED
                                                                                                                                                                                                                                                                    PVC DRAINS CONNECT                Ø375 PVC OUT
                                                                                                                                                                                                                                                                    INTO GRATED PIT.
                                         SWALE - TYPICAL SECTION                                                                                                                                                                                                    GRADE AT 0.5%
                                                                       NOT TO SCALE                                                CONCRETE VEE 300mm                                                                                                TYPICAL BIORETENTION SCHEMATIC AND DETAILS
                                                                                                                                   WIDE
                                                                                                                                                                                                                                                     NOT TO SCALE




                                                                                                                                                                                                                                                              PROJECT:                                                                           JOB NUMBER
REV DATE DESCRIPTION         BY     CHKD DRAWN
                                             I GDETAL
                                                    IS                                                    SCALE                                                       APPROVED                                                                                PROPOSED SUBDIVISION                                                                    1856
                                                                                                                                                                                                                                                              AT WALTER HAY DRIVE, NOOSAVILLE
                                           DATUM                 AHD                                                                                                                                                                                                                                                                         SHEET:        OF
                                           DESIGN               MM
                                                                             0              50            100             150            200              250m      .................                                                                         FOR STOCKWELL PTY LTD
                                                                                                                                                                                                                                                                                                                                                       7        7


                                                                                                                                                                 Director: CAMERON LANDRETH                                                                   DRAWING TITLE:                                                                 DRAWING NUMBER         REV
                                           DRAWN                MM
                                                                                                                                                                           (RPEQ 19358)
                                                                                                         SCALE 1:5000 A3                                                                      p 07 5443 8285                                                  TYPICAL STORMWATER SECTIONS
                                           DESIGN CHECK          CL
                                                                                                                                                                 DRAWING STATUS               e [email protected] w www.barlowshelley.com.au
                                                                                                                                                                                                                                                                                                                                               SW07
                                                                            This drawing is not to be copied or amended without written permission from
                                           DATE                21-02-19                                                                                                FOR APPROVAL           a PO Box 899, Maroochydore,4558 ABN 89 215 591 077
                                                                            Barlow Shelley Consulting Engineers

Page 34

                                                                 Appendix




Stormwater Quality Objectives – Construction Phase

   -   SPP (2017), Part G, Appendix 2, Table A. Department of Infrastructure, Local
       Government & Planning (DILGP).

   -   Healthy Waterways Guidelines for Building Sites

Page 35

Appendix 2 — Stormwater management
design objectives

Table A: Construction phase — stormwater management design objectives

Application:
© Applies to all climatic regions.

Part 1 Construction phase — stormwater management design objectives

Issue Desired outcomes

Drainage control 1, Manage stormwater flows around or through areas of exposed soil to avoid contamination.
2. Manage sheet flows in order to avoid or minimise the generation of rill or gully erosion.

3. Provide stable concentrated flow paths to achieve the construction phase stormwater
management design objectives for temporary drainage works (part 2).

4. Provide emergency spillways for sediment basins to achieve the construction phase
stormwater management design objectives for emergency spillways on temporary
sediment basins (part 3).

 

Erosion control 1, Stage clearing and construction works to minimise the area of exposed soil at any
one time.

2. Effectively cover or stabilise exposed soils prior to predicted rainfall.

3. Prior to completion of works for the development, and prior to removal of sediment
controls, all site surfaces must be effectively stabilised* using methods which will
achieve effective short-term stabilisation.

 

Sediment control 1. Direct runoff from exposed site soils to sediment controls that are appropriate to the
extent of disturbance and level of erosion risk.

2. Allexposed areas greater than 2500 metres? must be provided with sediment controls
which are designed, implemented and maintained to a standard which would achieve
at least 80% of the average annual runoff volume of the contributing catchment
treated (i.e. 80% hydrological effectiveness) to 50mg/L Total Suspended Solids (TSS)
or less, and pH in the range (6.5-8.5).

 

Litter, hydrocarbons and other 1. Remove gross pollutants and litter.
contaminants 2. Avoid the release of oil or visible sheen to released waters.

3. Dispose of waste containing contaminants at authorised facilities.

 

Waterway stability and flood 1. Where measures are required to meet post-construction waterway stability objectives

flow management (specified in table B), these are either installed prior to land disturbance and are
integrated with erosion and sediment controls, or equivalent alternative measures
are implemented during construction.

2. Earthworks and the implementation of erosion and sediment controls are
undertaken in ways which ensure flooding characteristics (including stormwater
quantity characteristics) external to the development site are not worsened during
construction for all events up to and including the 1 in 100 year ARI (1% AEP).

 

® Note: Drainage, erosion and sediment controls should be appropriate to the risk posed by the activity for the relevant climatic region e.g. considering the
potential soil loss rate, monthly erosivity or average monthly rainfall.

© Note: An effectively stabilised surface is defined as one that does not, oris not likely to result in visible evidence of soil loss caused by sheet, rill or gully erosion
or lead to sedimentation water contamination.

page 80

Page 36

Part 2: Construction phase — stormwater management design objectives for temporary drainage works

 

Ue AACE Eton eed eta ice eee Cem oe LiLe|
PU Tees
pee wi eliidird Phe smelt) pee Muar
Drainage structure 1in 2 year 1in5 year 1in 10 year
ARI/39% AEP AR1/18% AEP ARI/10% AEP
Where located immediately up-slope of an occupied 1in 10 year ARI/10% AEP

property that would be adversely affected by the
failure or overtopping of the structure

Culvert crossing 1in1year ARI/63% AEP

 

Part 3: Construction phase — stormwater management design objectives for emergency spillways on
temporary sediment basins

 

Drainage structure Anticipated operation design life and
PES
Reus Beaudry PEM Cy rd
Emergency spillways on temporary sediment basins 1in 10 year 1in 20 year 1in 50 year
ARI/10% AEP ARI/5% AEP ARI/2% AEP

Note: Refer to IECA 2008 Best Practice Erosion and Sediment Control (as amended) for details on the application of the
Construction Phase requirements. Advice should be obtained from a suitably qualified person e.g. Certified Practitioner in
Erosion and Sediment Control, or Registered Professional Engineer Queensland, with appropriate knowledge and experience
in erosion and sediment control design and implementation.

State Planning Policy page 81

 

Page 37

Table B: Post construction phase — stormwater management design objectives
Application:

(a) A material change of use for an urban purpose that involves premises 2500 metres? or greater in size and:
(a) will result in six or more dwellings; or
(b) an impervious area greater than 25 per cent of the net developable area.

(2) Reconfiguring a lot for urban purposes that involves premises 2500 metres? or greater in size and will result in six or more lots.

fete teressatei) Design objectives
Reductions in mean annual load from unmitigated development (%)

Total Total Total foro) Waterway stability

STs eT (| phosphorus aces 4) POU CMU CLE lil’

solids (TSS) (TP) (TN) PT
South East Queensland 80 60 45 90 Limit the peak 1-year
ARI event discharge
within the receiving
Central Queensland (north) 75 60 4o%s 90 waterway to the

pre-development peak

 

Central Queensland (south) 85 60 45 90

Cape YANKS, wet tropics and 80 60% 40 90 1-year ARI discharge
dry tropics
Western Queensland’ 85 60 45 go

Notes:

* Mapping of climatic regions is available on the State Planning Policy Interactive Mapping System.

¢ In lieu of modelling, the default bio-retention treatment area to comply with load reduction targets for all Queensland regions
in 1.5 per cent of the contributing catchment area.

* Water stability objective applies if development drains to an unlined waterway within or downstream of the site where a risk of
increased erosion exists due to changes in hydrology. Local government may also require application of the waterway stability
objective where there are planned future rehabilitation works to return a lined channel to a natural channel design.

* The SPP Water quality guidance material provides advice on the measures that demonstrate compliance with table B.

™ Note: Applies to population centres greater than 25,000 persons.
Note: Mackay Regional Council has adopted a 35 per cent reduction for TN.

Note: Townsville City Council has adopted a 65 per cent reduction for TP.

page 82

Page 38

 

Controlling stormwater pollution
on your building site

raat Ua,

Ce ul Wee TE 7 F | a

 

Page 39

 
 

a Le LT ya

 
  
 
  
   
    
    
  
  
  
  
 
 
 
   
    
 
  

a | x | : |

av Pe os ea ‘ 7
cy Introduction
What are the impacts?.............:-. ETS These guidelines provide a practical guide to best

practice techniques to minimise stormwater pollution from
building sites. They are designed to help people involved
in the building industry comply with their statutory
environmental duties and avoid large fines.

Erosion and sediment control on
residential building sites.......... Pee

Ula VT ce at palsa0) £211) ieee aS eae eee Pa
The following fact sheets provide practical examples
of recommended control measures. Included is an easy-
to-follow daily site checklist to guide site supervisors.

Erosion controls. .

Sediment control.........-..--

5 a Erosion and sediment contro! daily site check list
ie} |ay- le |= al eo) a) so) RP area rarer eer a eye ee

@® Erosion and sediment control on residential
1=0T] Ce Tate Me) 0-1 6-1 (¢) «era 4 building sites

Erosion control
@ Sediment control

Drainage control
Erosion and Sediment Control] Management Plans . . . Building operations

Storage of materials on hard surfaces..............

Grouped building lots...........

@ Storage of materials on hard surfaces
@ Grouped building lots

@ Erosion and Sediment Control Management Plans

CUTE) BEST PRACTICE
daily site check list Best practice is the management of an activity to ensure

environmental harm is minimised using cost-effective
An erosion and sediment control check list has been measures. These practices are assessed against national
developed to assist builders and site supervisors and international standards.
managing the task of control measure maintenance.
SAVE MONEY TIME AND ENERGY
Some of the benefits to home owners, builders and
the building industry include:

For further information on erosion and sediment control,
contact your local council

all-weather site access

improved wet weather working conditions
LEGEND sites do not get boggy

less mud and dust problems

reduced stockpile losses

reduced clean-up costs

a better public image

more marketable sites

fewer public complaints

reduced risk of fines

better fishing for everyone

healthier waterways.

National and international experience shows that the
cost of effective pollution management on building sites

is greatly reduced within the first few years as builders
become experienced with the various techniques.

Page 40

 

 

What are the impacts?
Soil, sediment and litter from building sites can be major
sources of stormwater pollution, and can cause:

* negative impacts on recreational fishing and
the seafood industry

© sediment build-up within waterways which
can lead to weed growth

e loss of valuable topsoil

 

© — significant public safety problems when washed

onto roads and intersections Mud and dirt on road after rain due to poor
on-site erosion and sediment control

¢ blocked drains and water sensitive urban design
features leading to flooding and increased

maintenance costs to the community

¢ significant harm to the environment of freshwater
and marine systems through the loss of valuable
seagrass habitat for marine creatures

¢ public health issues from increased algal blooms

¢ reduced recreational opportunities due to increased
turbidity

 

Sediment moving out of Moreton Bay into the ocean
through Jumpinpin

Erosion and sediment control on residential building sites

Principles of effective stormwater pollution control include:
¢ — sensible site planning

* — diversion of up-slope water (where appropriate)

¢ — stabilised site entry/exit point

¢ minimisation of site disturbance and duration of
disturbance

¢ installation of sediment controls along the lower
edge of the site

* appropriate location and protection of stockpiles
¢ early connection of roofwater downpipes

© — trap on-site run-off from tool, paint and concrete
washing and brick, tile and concrete cutting

* continual monitoring and maintenance of all
control measures

¢ compaction of backfilled trenches
* revegetation and stabilisation of the site

¢ development and implementation of Erosion
and Sediment Control Management Plans
when appropriate.

 

Control measures in place on a residential building site

Page 41

on your building site
: rs

 

 

When planning the site layout, building location and earthworks, it is possible to minimise the number
of control devices needed for the sediment control zone, and their interference with the building process,
with a little forward thinking. Suggestions are to:

  

minimise the reshaping of the land

direct stormwater to flow around the building area and any unstable batters

allow room for a sediment barrier, eg. sediment fence, to be located along the lower side of the disturbance
design the home to suit the property type, eg. construct pole homes on steep properties

avoid the permanent use of long, steep and unstable driveways

avoid the use of exposed aggregate concrete surfaces in areas where the wash-off cannot be contained.

Sediment Control Zone

The sediment control zone is any
area of land disturbance which has

potential for the erosion of sediments.
This area should be protected by a
downslope sediment control

measure or device:

 

  

Good site planning Poor site planning — stockpile over

sediment fence, materials and toilet
stored outside building site

Environmental law

The Environmental Protection Act 1994, Environmental Protection (Water) Policy 1997 and the Integrated Planning
Act 1997 are important pieces of legislation that control the way in which soil erosion and sediment are required to
be dealt with on building and development sites.

Breaches of the Environmental Protection (Water) Policy
1997 may result in:

on-the-spot fines under the Environmental Protection
(Water) Policy 1997 (ranging from $300 to $600)

prosecutions under the Integrated Planning Act
1997 or the Environmental Protection Act 1994
(fines of thousands of dollars or prison sentences
for serious offences)

 

the prosecution of individuals and/or companies. Council officer explaining the Environmental Protection
(Water) Policy 1997

Page 42

 

Erosion controls eazam=z
MINIMISE DISTURBANCE

¢ — Earthworks should be kept to a minimum, and should only be commenced immediately prior to building works.

¢ Maintain as much soil coverage as possible with the use of grass, leaf litter and mulch, gravel or erosion control
blanket (ECB) or matting.

* Vegetation located down-slope of the work site assists in filtering out sediment. Where practicable, maintain
kerb vegetation such as grass and turf strips in a healthy state during the building process.

 

"STOCKPILES

° Stockpiles and building materials should not be stored
on the footpath or within the road reserve. Permission
must be obtained from your Council to store materials
in these areas otherwise fines may be imposed.

° Minimise stockpile losses with the use of covers.

° All stockpiles and building materials should be located
within the sediment control zone, for example up-slope
of a sediment fence.

 

° Stockpiles must not be located within an overland flow
path.

Stockpiles without protection

Backfill service trenches, cap with topsoil, and compact to a level at least 75-100 mm above the adjoining ground
level (either manually or with a small machine). This allows for some subsidence of the fill material, and ensures the
fill is sufficiently compacted to avoid erosion at a later time. (Note that trenches must be backfilled in accordance
with AS3500).

EROSION CONTROL BLANKETS OR MATTING
Erosion contro! blankets or matting can be used to minimise
soil erosion and stormwater pollution from sites by:

* containing high erosion risk soils

¢ — stabilising steep slopes.

All areas disturbed by building activities should be promptly
and progressively stabilised, using techniques such as
revegetation and landscaping, so they no longer act as
sources of sediment.

 

MULCHING AND GARDEN BEDS.
To minimise soil loss, mulch should be applied to open Rehabilitate the site promptly'to reduce the chances
garden beds at a depth of 75-100 mm. of further erosion

This will assist in plant establishment, minimise water
loss and help to control weeds.

Ensure that mulch is stabilised on unstable slopes (e.g. batters and riparian areas) to avoid it washing away and
ultimately entering waterways.

Page 43

ay La site

 

Sediment control
STABILISED ENTRY/EXIT POINT (RUMBLE PAD)
¢ Manage entry/exit point (rumble pad) so that sediment is not tracked
off the site.

© — Restrict site access to one stabilised location.

* Recommended construction method for stabilising access points
is a 150-200 mm deep pad of minimum 40 mm crushed rock.

¢ The pad should be at least 2 metres wide and extend from the kerb
to the building slab.

¢ Where the entry/exit pad slopes towards the road, a 200 mm high bund (hump) should be installed across the
pad to deflect stormwater run-off to the side where it can be filtered by a sediment fence.

Note: The location of the permanent driveway may not be an appropriate location for the construction entrance.

¢ — Install sediment barriers along the lower
side of the soil disturbance.

 

Stabilised gravel entry/exit point (rumble pad)

 

© The most efficient sediment barrier for
building sites is specially-manufactured
geotextile sediment fencing.

¢ Sediment fences on building sites
are usually wire-tied to steel or hardwood
posts (wire-tied sediment fences have the
advantage of being more readily unhooked
from their support posts).

© The support posts are spaced no greater
than 2 metres apart and the sediment
fence buried to a depth of 200 mm.

* — For public safety and sediment control
efficiency, sediment barriers should not be
located outside property boundaries without Council approval.

 

Sediment fence

¢ Sediment barriers should only be placed on the road as a last resort.

* — Sediment barriers placed in front of roadside stormwater inlets are rarely as effective as onsite controls and
at best usually result in the sediment being washed down the street and into the nearest open gully inlet.

* Only use proper geotextile sediment fence fabric. Don't use filter cloth or shade cloth.
USE OF SIGNS

Public signs that warn of the need for proper sediment control devices and
maintenance are becoming more widely used. Contact your council for further
information.

 

Sediment control information signage

Page 44

 

MAINTENANCE OF CONTROL MEASURES

All erosion, sediment and drainage control measures need to be regularly
checked and maintained in good working order. Best practice includes
anticipation of potential risks and being prepared for abnormal
circumstances and emergencies. These measures include:

* — Stockpile extra sediment fence fabric and posts on-site to facilitate
emergency repairs.

¢ — Reapply crushed rock to the entry/exit pad (rumble pad) when
sediment build-up occurs.

¢ — Repair eroded drainage channels with rock, turf or erosion control
blankets or matting.

¢ — Ensure built-up sediment is removed at regular intervals from
sediment barriers.

* — Check and replace/repair sediment barriers daily if they are ripped,
damaged or no longer anchored.

 

from entry/exit point (rumble pad) and

Drainage control additional crushed rock applied
DIVERSION OF UP-SLOPE WATER

¢ Where practicable, divert up-slope water around the disturbed area.
© — Stormwater can be diverted with the use of small turf or geotextile lined catch drains, or with the use of
diversion banks,

¢  Diverted stormwater should be discharged onto stable ground (for example turfed areas) and should not
be diverted into neighbouring properties unless written permission is obtained from the land owner(s).

_ EARLY ROOF WATER CONNECTION

¢ Temporary or permanent downpipes should be installed as soon as
practicable after the roof is laid.

¢ Early connection of roof water to the stormwater system will reduce site
wetness and the generation of on-site mud. This has been shown to
reduce downtime following storm events and decrease the average
building construction time.

 

Temporary roof water connection

Page 45

on your building site
. fe

 

Building operations

Prior to commencing building work

¢ Obtain all necessary permits, licences and approvals.

¢ Prepare a site specific Erosion and Sediment Control (ESC) Management Plan and have all necessary
ESC materials available.

e Avoid clearing vegetation and excavating until ready to build.

© Where necessary in new estates, temporary revegetation may be required.

Points to consider as part of building operations

* Tool and paint washing, brick, tile or masonry cutting and water-cooled cutting activities should be done
within the property boundaries.

¢ — All waste water should be contained on-site where possible.
¢ Activities should be carried out on a permeable surface or up-slope of an infiltration trench.

¢ — Vehicles should not be parked on the footpath area or verge where they can damage essential vegetation
and transport dirt onto the road.

¢ Contain waste concrete washed from trucks, mixers and barrows on site; do not wash out into stormwater
systems as this can clog drains and cause flooding during storm events.

  

All hard waste should be stored on-site in a way that prevents material loss caused by wind or water. Smaller

materials such as litter should be contained in covered bins or litter traps formed on three sides by a geotextile
wind break or similar device.

 

When travelling to and from the site, secure load to prevent wind blown litter polluting our waterways and roadsides.

 

One way to properly store building waste Poor litter and building waste storage

Remove accidental spills of soil or other materials from the road,

gutter or any location outside the control of the primary sediment

barrier:

¢ immediately if it is raining or likely to rain during the day

* at least upon completion of the day's work (even if rainfall is
unlikely during the night)

* use a broom and shovel instead of hosing to clean hard surfaces,

* clean up food packaging after meal breaks as this litter can enter
stormwater systems and waterways.

 

Following storms, the road reserve and sediment barriers should be Undertake regular site clean-ups
inspected and excess sediment residue removed.

Page 46

 

Fully contain concrete waste washed from trucks and mixer units on-site and store where it cannot be washed from
the site, harming the environment.

    

¢ Builders need to demonstrate how they intend to prepare exposed aggregate surfaces without allowing cement
residue to flow into stormwater drains or waterways.

 

° Where practicable, wash cement residue onto pervious surfaces or fully contain it within temporary sediment
dams created from tightly stacked sand bags.

© When suitably dry, shovel cement residue into a waste disposal bin.
e  Atno time should cement residue or wastewater run-off enter the roadside gutter.

This may make it impractical on some sites for exposed aggregate driveways to be constructed. In such cases,
an alternative driveway finish must be used.

 

Storage of materials on hard surfaces eezzz

Whenever possible, materials should be stockpiled within the sediment
control zone and, where necessary, covered with waterproof sheeting to
minimise the potential for transport of sediments in stormwater.

Materials may be temporarily stored on hard surfaces only where it is
necessary to place erodible material on hard surfaces to undertake
work and no other reasonable options are available.

 

Don’t store stockpiles on hard surfaces without
suitable protection

Grouped building lots

When one builder controls more than one building lot, combined-lot sediment control structures may be placed

down-slope if:

¢ the combined sediment control measures provide a level of protection at least equal to that provided by
individual lot protection

¢ The builder accepts responsibility for the ongoing monitoring and maintenance of sediment control devices

¢ suitable drainage and erosion contro] measures are applied to each building lot

¢ a suitable sign is placed in a prominent location outside each lot and/or at the entrance of the
estate indicating such controls are in place.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.