Compiled Decision Notice 132002.220611.4 14 Serenity Cl Noosa Heads
132002.220611.4
60.7. The construction of the whole of the foundations is to be carried out in accordance
with the recommendations of the applicant’s consulting Geotechnical engineer,
including any on-site supervision required by these recommendations. Such works
shall only be carried out during dry weather conditions and if there is a risk of sand
movement occurring, all work shall be suspended until such steps, approved by the
applicant’s consulting Geotechnical engineer have been undertaken to ensure that
no further slippage will result.
60.8. Construction Management Plans are required to be forwarded to Council at the
time of Operational Works Applications.
61. A verification survey of the building is to be carried out by a Licensed Surveyor and a
certificate lodged with Council at completion of the work confirming compliance with the
maximum building height above natural surface, required by the provisions of the
Planning Scheme.
ENVIRONMENTAL HEALTH
62. The developer shall comply with the Refuse Management Plan Reference Ryter
Planning RCU 1005.
63. The developer must provide a suitably screened imperviously paved area large enough
for all refuse and recycling containers. A wash down area is required with a cold-water
tap, hose and drain outlet connected to sewer. The drain outlet is to be designed to
prevent stormwater entry to the sewerage system.
64. Street litter bins to a design approved by Council, shall be supplied and installed at the
developers expense at agreed locations.
65. Refuse chutes must be provided, in accordance with Council’s Policy for Refuse Chutes
and Accessories in Multi Storey Buildings.
66 Swimming pool or spa pumps are to be contained in an acoustically treated enclosure or
located in a manner which prevents a noise nuisance beyond the subject land in
accordance with the nuisance provisions of the Environmental Protection Regulation
1998. On the spot fines apply for such offences.
67. Air conditioning units shall be located in a manner which prevents noise nuisance
beyond the subject land in accordance with the nuisance provisions of the
Environmental Protection Regulation 1998 and Council’s Local Law No. 12 - Control of
Nuisances. On the spot fines apply for such offences.
An occupier of premises where there is air-conditioning equipment must not use or allow
the use of the equipment -
67.1 before 7am or after 10pm on any day if it makes noise or causes noise to be made
of more than the higher of the following -
67.1.1 40 dB(A)
67.1.2 3 dB(A) above the background noise level
67.2 from 7am to 7pm on any day if it makes noise or causes noise to be made of more
than the lower of either of the following -
67.2.1 50 dB(A)
67.2.2 5 dB(A) above the background noise level
67.3 from 7pm to 10pm on any day if it makes noise or causes noise to be made of
more than 3 dB(A) above the background noise level.
Page 10 of 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Decision Notice 132002.220611.4 14 Serenity Cl Noosa Heads.pdfRelated documentApplication case desk ↗
About this file
- File size
- 70 KB (small file)
- File type
No other editions are linked here.