Electrical installation
Electrical installation diagram On-site facilities for operating element
Surface-mounted operating element
110
= =
6
Electrical specifications (services to be provided by the customer)
Nr. Quantity Designation Position Frequency
1 1 Power meter in the supply cable
Pre-fuse:
2 1 3x safety fuse 20 A (slow-blow) or
in the supply cable 1x per unit
Circuit breaker 3x 20 A (trip characteristic K or C)
Supply cable 5 x 2.5 mm² (3 PH+N+PE) with marked wires and
3 1 to master switch 1x per unit
protective earth
4 every 10 m Foundation earth connection Corner of pit floor
Equipotential bonding in accordance with DIN EN 60204
5 1 1x per system
from foundation earth connection to system
Empty pipe EN 25 (M25) from pit floor to operating
6 1 1x per system
with taut wire element
Empty pipe EN 50 (M50)
7 1 Supply cable to unit 1x per unit
with taut wire
8 1 Operating stands 1x per system
from the supply cable into
9 1 Separate supply cable 230 V with lighting and socket 1x per system
the shaft
Electrical specifications (KLAUS Multiparking scope of supply)
Nr. Designation
10 Switch cabinet with lockable master switch
11 Control cable 3 x 0.75 mm² (PH+N+PE)
12 Control cable 7 x 1 mm² with marked wires and protective earth
13 Operating element
14 Control cable 4 x 2.5 mm² with marked wires and protective earth
15 Hydraulic unit 5.2 kW, three-phase current 230/400 V / 50 Hz
Product data MultiBase U10 EB 588.52.620-005 04/2023 English 11