Skip to the record
Mmm.. taste the original NoosaWatch™

Original source · versioned page text

Traffic Impact Statement

of 52

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Technical information
Usage area                                                                       Care

The system is suitable for a fixed group of users as standard.                   To prevent corrosion damage, please observe our special cleaning and care
Where users change (e. g. short-term parking in office buildings or hotels),     instructions and ensure that your garage is well ventilated.
structural modifications are required. Please request a consultation if re-
quired.                                                                          Corrosion protection

Units                                                                            In accordance with the ‘Corrosion protection’ supplement.

Low-noise, bearing-mounted hydraulic units are installed on rubber-metal         Protective grille
blocks. Consequently, we recommend separating the garage body from the
residential building.                                                            If the permissible fall opening is exceeded, protective grilles must be in-
                                                                                 stalled on the systems. If there are roadways immediately adjacent to or be-
Ambient conditions                                                               hind the systems, the customer must provide barriers in accordance with DIN
                                                                                 EN ISO 13857. This also applies during the construction stage.
Ambient conditions for the areas around Multiparking systems:
    Temperature: Temperature range -20 to +40° C. Relative humidity 50 %         Noise protection
    for a maximum outside temperature of +40° C.
    Wind: Peak speed pressure during gusts of wind 1.05 kN/m² according          Standard noise protection:
    to DIN EN 1991-1-4.                                                          In accordance with DIN 4109-1 Noise protection in high-rise - Section 9:
    Snow: characteristic snow load of 6.86 kN/m² according to DIN EN             Maximum sound pressure level in living and sleeping areas 30 dB (A).
    1991-1-3. Snow load data apply to the lowered system (see "Vehicle data",    User noise is not subject to the requirements.
    page 4)
                                                                                 The following dimensions are required for adherence to this value:
If ascent/descent times are specified, these relate to an ambient tempera-
                                                                                    Noise protection package in accordance with quote/order
ture of +10° C and with the system positioned immediately adjacent to the hy-
                                                                                    (KLAUS Multiparking)
draulic unit. These times are increased at lower temperatures or with longer
                                                                                    Sound insulation dimension of the building structure of min. R’w = 57 dB
hydraulic lines.
                                                                                    (service to be provided by the customer)

Seismic conditions                                                               Increased sound protection (special agreement):
                                                                                 In accordance with DIN 4109-5 Increased noise protection in high-rise - Sec-
Local seismic conditions may require special precautions such as strutting.      tion 8:
Please contact KLAUS Multiparking for seismic reports and advice.                Maximum sound pressure level in living and sleeping areas 25 dB (A).
                                                                                 User noise is not subject to the requirements.
Water condensation                                                               The following dimensions are required for adherence to this value:
If a warm vehicle is parked, the interior temperature of the enclosed space         Noise protection package in accordance with quote/order
will increase quite considerably despite the designed ventilation (see "Ven-        (KLAUS Multiparking)
tilation", page 14). If the heated air comes into contact with cold ele-            Sound insulation dimension of the building structure of min. R’w = 62 dB
ments such as concrete and steel, it cools down and forms condensation. As          (service to be provided by the customer)
warmer air generally rises, this effect will primarily be seen on the platform   Note:
undersides of the multiparking system. Water condensation is an unavoid-         User noise is noise that can be influenced individually by the user of our Mul-
able physical effect.                                                            tiparking systems. This includes, e.g., accessing the platform, the slamming
                                                                                 of vehicle doors, engine and brake noise.
Building application documents

Multiparking systems generally require approval. Please observe local regu-
lations and stipulations.




Product data      MultiBase U10 EB        588.52.620-005       04/2023       English                                                                      12
Log in to download the original file

Traffic Impact Statement.pdf · 8.2 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.