Performance outcomes Acceptable Outcomes
PO50 AO50.1
Building entries are visible and easily identifiable. The number of entrances and exits are limited and main building
entrances/exits are located at the front of the site in view of the
street, or where this is not possible, due to site or existing building
constraints, a welldefined path is provided to the entrance/exit.
AO50.2
All entrances/exits to buildings, are well lit and signed, and
signage includes hours of operation.
AO50.3
Entrances/exits are located to provide a direct link to driveways
and car parking areas.
AO50.4
Recessed doorways are avoided where the recess is of sufficient
size to conceal a person. Where recessed doorways are
unavoidable, the following measures are used to enhance safety:
(a) good lighting;
(b) strategically placed mirrors;
(c) angled approaches; or
(d) gates which restrict access.
Vandalism
PO51 AO51
Buildings and structures are designed to minimise opportunities Buildings or structures that are visible or accessible from a public
for vandalism. street or laneway:
(a) avoid the use of solid fences and blank walls which attract
graffiti. Where solid blank surfaces are unavoidable,
measures in the form of landscaping, creepers, murals,
vandal resistant paint, etc. are used;
(b) with windows at ground level use measures that deter
break and enters without obscuring views to shopfronts;
and
(c) are constructed to be vandal and graffiti proof.
Lighting
PO52 AO52.1
Lighting of appropriate intensities is provided to maximise safety. Lighting of appropriate intensities is provided which satisfies the
requirements of Australian Standard AS1158: Public Lighting
Code, unless otherwise specified in this Code.
AO52.2
External lighting of a graduated intensity is provided which starts
at a lower level of brightness at the perimeter of the site and rises
to a higher level at the entrance to buildings or at the centre of the
site.
AO52.3
Lighting is directed onto the site and away from neighbouring
properties.
AO52.4
Vandalresistant lighting is used in public and publicly accessible
areas