Performance outcomes Acceptable Outcomes
Caretaker’s accommodation
PO7
Development for caretaker’s accommodation: No acceptable outcomes provided
(a) is directly associated with and subordinate to the industry
activity on site;
(b) demonstrates a demand for 24 hour care of buildings,
operations, plant or equipment;
(c) is not separately let for other accommodation activities;
(d) includes no more than one caretaker’s accommodation per
site;
(e) is on a site with an area of at least 2,000m2;
(f) has a maximum gross floor area of 65m2; and
(g) is occupied by at least one person who is employed by the
primary nonresidential use onsite.
Hofmann Drive Business and Industry Precinct
PO8 No acceptable outcome provided
The nature, design and operation of development and uses is
compatible with industry activities of the adjoining Medium Impact
Industry zone, the nearby residential uses and the business
activities within the Noosa Business Centre.
Built form Table 6.5.1.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
All activities
Built form
Height
PO9 AO9.1
Buildings and other structures— Buildings and structures are no more than 10 metres in building
(a) are low rise and have a visual bulk and architectural scale height.
consistent with structures on adjoining and nearby land;
Factory Street Business and Industry Precinct
(b) have a maximum building height of 2 storeys;
AO9.2
(c) do not visually dominate the street or surrounding spaces; Buildings and structures are no more than 8 metres in building
(d) preserve the amenity of surrounding residential height.
development including privacy, views and access to
sunlight; and AO9.3
Where excavation is required, the maximum portion of the
(e) respond to the topography of the site; and
exposed external façade of the building cannot exceed the
(f) are well articulated with strong horizontal and vertical respective building heights in AO9.1 and AO9.2
elements to provide interest to the street.
Editor's note—refer to figure AP313A