Our Ref:        ATP150314-L-NIA-02
Enquiries to:   Sasho Temelkoski




10 December 2015



Noosa Council
PO Box 141
TEWANTIN QLD 4565




Attention: Denis Wallace                                        E-mail: [email protected]



Dear Sir,
Re:       Village Bicycle at 2 Bottlebrush Avenue, Noosa Heads – Consideration of
          2.6m high acoustic fence

This letter is an addendum to the acoustic report prepared by ATP Consulting Engineers
(ATP150314-L-NIA-01) dated 9 October 2015 for the Village Bicycle at Shop 1, 2 Bottlebrush
Avenue in Noosa Heads.

1. Project Background

The noise impact assessment by ATP Consulting Engineers, dated 9 October 2015,
demonstrated that the noise emissions from Village Bicycle complies with the environmental noise
criteria, provided a 2m high acoustic fence is constructed along the north-eastern boundary with
Bottlebrush Avenue.

Noosa Council has requested a “more robust solution”, therefore this report considers raising
height of the fence to 2.6m.




 ATP Consulting Engineers                            E: [email protected]
                                P: +61 7 5593 0487
 Suite 5, 23 Main Street                             ABN: 95 634 079 845             www.atpconsulting.com.au
                                or: 0413 055 994
 Varsity Lakes, QLD 4227                             atf ATP Engineering Trust
Log in to download the original file

ATP150314-L-NIA-02.pdf · 274 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

Full text of the other 4 pages

Page 2

2. Environmental Noise Criteria

Noosa Council requires that the noise levels from Village Bicycle do not exceed the limits
presented in Table 2.1, at the nearest noise sensitive receptors.

                                                Table 2.1 Noise Criteria
                                                                                             Criteria
                        Period                              Objective
                                                                                            (LAeq,adj,T)1
                        Day                                                                     55
                                           Background noise level (LA90,T)2 + 5dB(A)
                 (7:00am to 6:00pm)                                                          (50 + 5)
                      Evening                                                                   50
                                            Background noise level (LA90,T) + 5dB(A)
                (6:00pm to 10:00pm)                                                          (45 + 5)
                       Night                                                                    43
                                            Background noise level (LA90,T) + 3dB(A)
                (10:00pm to 7:00am)                                                          (40 + 3)


3. Noise Propagation Modelling

The SoundPLAN noise propagation model was modified as follows:
        Height of the acoustic fence on the north-eastern boundary of the café was raised to 2.6
         metres.

The calculated noise levels at the nearest apartments at No. 1 Bottlebrush Avenue, considering
patron and music noise emissions from Village Bicycle café when operating at full occupancy (1-
hour period of highest noise), are presented in Table 3.1 and Appendix A.

                                         Table 3.1 Calculated Noise Levels
                                                                           Environmental
                                                       Calculated SPL*
                                                                           Noise Criteria
               Receiver              Location             Leq,adj,1-hour                       Compliance
                                                                              Leq,adj,T*
                                                            dB(A)
                                                                               dB(A)
                                 First floor balcony          38                                     Yes
           No. 1 Bottlebrush
                                                                             Night: 43
                  Ave              Second floor
                                                              40                                     Yes
                                     balcony
          *Free-field




1 A-weighted equivalent continuous adjusted sound pressure level (L
                                                                    Aeq,adj,T) from all noise sources at Village Bicycle
combined.
2 Typical background noise level corresponding with noise area category R3 from AS1055.3-1997.




www.atpconsulting.com.au                                                                                           2

Page 3

4. Discussion

The results of the noise propagation modelling indicate compliance with the relevant
environmental noise criteria at all times.

The proposed 2.6m high acoustic fence should follow the alignment of the existing fence.
Acceptable construction for the 2.6m acoustic fence is overlapping timber palings, fibre-cement,
or any other material with a minimum density of 12.5 kg/m2.

ATP Consulting is satisfied that with the proposed 2.6 metre high acoustic fence and
implementation of the other noise control measures as outlined in the detailed report dated 24
June 2015 (ATP150314-NIA-02), the operation of Village Bicycle café will not result in
unreasonable noise at the nearest noise sensitive places.



Should you have any questions about the noise assessment presented in this document, please
do not hesitate to contact our office on (07) 5593 0487.




Yours faithfully




Sasho Temelkoski MIEAust CPEng RPEQ MAAS
Managing Director and Principal Engineer




www.atpconsulting.com.au                                                                    3

Page 4

         Appendix A – Tabulated SoundPLAN Results




www.atpconsulting.com.au


[OCR of page images]
Air

Appendix A — Tabulated SoundPLAN Results

www.atpconsulting.com.au

Page 5

                Village Bicycle Noise Levels, Leq(1hr) A weighted
                           2.6m high acoustic fence

                                                                       SPL
                        Receiver                              Floor   Leq(1hr)
                                                                      dB(A)
                                                               F1       38
                 No. 1 Bottlebrush Avenue
                                                               F2       40




                                   ATP Consulting Engineers                  1
SoundPLAN 7.2

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.