Callaghan & Toth
APPENDIX 1 WATER SENSITIVE DESIGN CODE ASSESSMENT (NOOSA PLAN)
SPECIFIC OUTCOMES PROBABLE SOLUTIONS PROPOSED SOLUTIONS
Water reuse
01 Development uses a combination of detention and S1.1 Development complies with the water quality 81.1 The site is located within the Mary River catchment
retention systems to capture run-off from areas on the standards in Table 2 of the SEQ Regional Plan and adjacent to Blackfellow Creek. Blackfellow Ck is a
defined as a lowland freshwater on Plan WQ1381. The
site; Implementation Guideline NO.7 for Water Sensitive
EPP (Water)2009 -
Mary River environmental values and
AND Urban Design;
water quality objectives details that lowland freshwaters
have the following WQO’s:
02Water storage devices must have sufficient S2.1 No solution provided
Turbidity < 50 ntu
capacity having regard to local rainfall pattern and the 8uspended solids < 6 mg/L
catchment area of roof or other hard standing surface; Chlorphyll a < 5 ug/L
AND Total Nitrogen < 500 ug/L
Oxidised N > 60 ug/L
03Captured water is utilised for all non-potable uses S3.1 Captured water is plumbed to be available for all Ammonia N < 20ug/L
on site; external uses including gardening, irrigation, ponds, Organic N < 420 ug/L
Total phosphorus < 50 ug/L
filling swimming pools and outdoor cleaning, as well Fitlerable reactive phosphorus < 20 ug/L
AND as all ground floor toilet cisterns and washing
DO 85% -
110 % saturation
machine cold taps;
pH 6.5 -8.0
AND
82.1 and 83.1 & 3.2
S3.2 Where the captured water is used for toilet Rainwater tank volume to be 1 ,600kL with backup supply
flushing and/or laundry use, an automatic or manual from on-site dams to ensure sufficient water supply for
interchange device that allows alternate use of Poultrys.
captured water or the reticulated water supply is
installed to ensure that there is a continual supply of
water for sanitary flushing and laundry use.
04 On-site detention does not adversely impact on S4.1 No solution provided
water requirements downstream of the site where the 84.1 The site is 38 hectares in area and the proposal will
water is required to sustain the ecology and hydrology not affect runoff.
of downstream systems (environmental flows);
AND
85.1 N/A
05Within the Shire Business Centre site, as shown S5.1 No solution provided
A
1209 Animal Husbandry -
Top Forestry Rd, Ridgewood SWQMP_REV_3
SEPTEMBER 2013
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.