ORDINARY MEETING AGENDA 15 JUNE 2017
Erosion and Sediment Control
48. Any person acting on this permit shall prevent erosion and sediment export from
leaving the site. Site control measures such as silt fencing, controlled gravel access
to the site, controlled disposal of waste, catch drains, and temporary infiltration or sump
pump-outs will be necessary.
49. Plans detailing the methods of controlling erosion and sediment are required to be
submitted to the Council for approval prior to obtaining a Development Permit for
Operational Works. The applicant is advised that a simple silt fence by itself is unlikely
to meet the objectives of best practice for Erosion & Sediment Control.
Damage to Services and Assets
50. Any damage caused to existing services and assets as a result of the development
works must be repaired at no cost to the asset owner at the following times:
a. where the damage would cause a hazard to pedestrian or vehicle safety,
immediately; or
b. where otherwise, upon completion of the works associated with the development.
Any repair work which proposes to alter the alignment or level of existing services and
assets must first be referred to the relevant service authority for approval.
Community Management Statement Requirements
51. The Applicant and all future owners of the site shall comply with the Environmental
Management Plan (EMP) for Settlers Cove Development 23118 DA and compliance
with the EMP shall be referenced in any community management statement over the
site.
52. The Fire Management Plan is to be implemented by the Developer and future owners
of the site and is to be referenced in any community management statement.
Environmental Health
53. The developer must provide a suitably screened imperviously paved area large enough
for all refuse and recycling containers. A wash down area is required with a cold-water
tap, hose and drain outlet connected to sewer. The drain outlet is to be designed to
prevent stormwater entry to the sewerage system.
54. Street litter bins to a design approved by Council, shall be supplied and installed at the
developer’s expense at agreed locations.
55. Refuse chutes must be provided, in accordance with Council’s Policy for Refuse
Chutes and Accessories in Multi Storey Buildings.
56. Swimming pool or spa pumps are to be contained in an acoustically treated enclosure
or located in a manner which prevents a noise nuisance beyond the subject land in
accordance with the nuisance provisions of the Environmental Protection Regulation
1998. On the spot fines apply for such offences.
57. Air conditioning units shall be located in a manner which prevents noise nuisance
beyond the subject land in accordance with the nuisance provisions of the
Environmental Protection Regulation 1998 and Council’s Local Law No. 12 - Control of
Nuisances. On the spot fines apply for such offences.
An occupier of premises where there is air-conditioning equipment must not use or
allow the use of the equipment -
57.1 before 7am or after 10pm on any day if it makes noise or causes noise to be
made of more than the higher of the following –
57.1.1 40 dB(A)
57.1.2 3 dB(A) above the background noise level
Page 10 of 20