Log in to see the plans as drawnPERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES PROPOSED SOLUTION
b) adequate access for the evacuation of the subdivision, between the created lots and conditions for QFES with excellent exposure to the
residents and emergency personnel in an surrounding vegetated lands. forest edge for fire fighting purposes. Therefore, no
emergency situation. OR formal firebreaks are considered necessary. The
AO8.2 development will rely on the other bushfire risk
Fire access tracks are provided between the created management measures detailed within this
lots and surrounding vegetated land that: management plan to reduce the bushfire risk to an
acceptable level.
a) have a cleared minimum width of 6 metres; To ensure safe access and egress and operational space
for rural fire-fighting vehicles, where possible, the
b) have a maximum gradient of 12.5%;
existing driveways should be maintained as per criteria
c) provide unbroken access for fire fighting vehicles; set out in Assessment Benchmark 4 of the SPP Bushfire
d) provide passing bays and turning areas; which nominates:
e) are located within an access easement that is 1. A trafficable area (cleared and formed):
granted in favour of Noosa Council and the Queensland a) with a minimum width of 4 metres that can
Fire and Rescue Service. accommodate a rural firefighting vehicle
b) with no less than 4.8 metres vertical clearance from
AO8.3 canopy vegetation
Bushfire management measures are carried out on the
c) with no adjacent inhibiting embankments or
subject property and not any adjoining property.
retaining walls
2. A working area each side of the trafficable area:
a) with a minimum width of 3 metres each side
b) cleared of all flammable vegetation greater than 0.1
metre in height
AO8.3 – All bushfire management measures prescribed
herein would be carried out on the subject property
and not rely upon any adjoining property.
JULY 2022 BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN Page: 35
296 KIDD ROAD, POMONA