Approved Plans MCU22-0147

of 72

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (11.2 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
PERFORMANCE OUTCOMES                       ACCEPTABLE OUTCOMES                                      PROPOSED SOLUTION
b) adequate access for the evacuation of   the subdivision, between the created lots and            conditions for QFES with excellent exposure to the
residents and emergency personnel in an    surrounding vegetated lands.                             forest edge for fire fighting purposes. Therefore, no
emergency situation.                       OR                                                       formal firebreaks are considered necessary. The
                                           AO8.2                                                    development will rely on the other bushfire risk
                                           Fire access tracks are provided between the created      management measures detailed within this
                                           lots and surrounding vegetated land that:                management plan to reduce the bushfire risk to an
                                                                                                    acceptable level.
                                           a) have a cleared minimum width of 6 metres;             To ensure safe access and egress and operational space
                                                                                                    for rural fire-fighting vehicles, where possible, the
                                           b) have a maximum gradient of 12.5%;
                                                                                                    existing driveways should be maintained as per criteria
                                           c) provide unbroken access for fire fighting vehicles;   set out in Assessment Benchmark 4 of the SPP Bushfire
                                           d) provide passing bays and turning areas;               which nominates:

                                           e) are located within an access easement that is         1. A trafficable area (cleared and formed):
                                           granted in favour of Noosa Council and the Queensland    a) with a minimum width of 4 metres that can
                                           Fire and Rescue Service.                                 accommodate a rural firefighting vehicle
                                                                                                    b) with no less than 4.8 metres vertical clearance from
                                           AO8.3                                                    canopy vegetation
                                           Bushfire management measures are carried out on the
                                                                                                    c) with no adjacent inhibiting embankments or
                                           subject property and not any adjoining property.
                                                                                                    retaining walls
                                                                                                    2. A working area each side of the trafficable area:
                                                                                                    a) with a minimum width of 3 metres each side
                                                                                                    b) cleared of all flammable vegetation greater than 0.1
                                                                                                    metre in height
                                                                                                    AO8.3 – All bushfire management measures prescribed
                                                                                                    herein would be carried out on the subject property
                                                                                                    and not rely upon any adjoining property.



                    JULY 2022                       BUSHFIRE HAZARD ASSESSMENT & MANAGEMENT PLAN                              Page: 35
                                                                296 KIDD ROAD, POMONA
Log in to download the original file

Approved Plans MCU22-0147.pdf · 11.2 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.