Architecturals 08.01.21
Original PDF page 10, section 1. The text section number identifies this passage in the reader.
client to verify
refrig. opening
clearances
underside truss
plasterboard
cornice lining to ceiling
pine frame
bulkhead ref
prov
BUTLERS
OPEN TO FAMILY ROOM
plasterboard PANTRY
KITCHEN 2
canopy rangehood
KITCHEN 1
cabinetmaker to over cooktop
supply 100mm infill
1,820
plane in and no more gaps
mw
overhead 1,000 space
cupboard door cupboard min.
the number of doors and width of doors
KITCHEN BULKHEAD DETAIL will be determined by the cabinetmaker to
SCALE : N.T.S. optimize the functionality of the cabinetry
KITCHEN / WIP 3
frz.
space
dw min.
FG panel
vanity 900 vanity 1200
shower fixed mirror fixed mirror freestanding
bath
freestanding
bath
04-06
BATH 1
BATH 2
BATH 3
BATH 4
niche
freestanding bath
vanity
detail
vanity 1800
shower fixed mirror wc shower wm taps
LAUNDRY 1
under
ENSUITE 1
ENSUITE 2
ENSUITE 3
ENSUITE 4
open to bench
master
wc
wm
space
NOTES PLAN LEGEND CLIENT:
PLEASE READ CAREFULLY
10. Protection against subterranean termites shall be in accordance with AS
THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE
G. LEWIS & S. PAESSEY
1. Written dimensions take precedence over scale. 3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with afl = above floor level ref = refrigerator prov. CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
2. Builder to verify all dimensions and levels prior to commencement of construction. approved collars/barriers at slab penetrations. hd = head at 2100 afl. mw = microwave prov. HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
3. All internal dimensions stated are frame size - excluding linings. 11. HWS unit (constant flow) with 5 star energy efficiency rating to comply fw = floor waste dw = dishwasher prov. OTHER PREVIOUS PLANS OR SKETCHES.
Lot 4, 297 Lawnville Road
4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005. = smoke detector pty = pantry
timber framed construction). 12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC vb = vanity basin wm = washing machine prov. BLACK MOUNTAIN
Stroud Homes Pty Ltd 5. Supplier may substitute lintels for those of equal strength to span ratio. PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003 obs = obscure glazing ghw = gas hot water unit
ABN: 49 107 897 736 QBSA Lic No: 1083367 6. All structural sizes to be read in-conjunction with structural engineers drawings & AS/NZS 6400:2005. mb = meter box tr = towel rail MODEL: JOB
OWNER/S No. 20L297LA
details. 13. Lift off hinges to all WC doors to comply with Australian Standards. dp = downpipe trh = toilet roll holder Montego 329 Skillion
107 Sugar Road Telephone: Email: 7. Articulation joints to complay with 3.3.1.8 BCA Vol 2. 14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt ohc = overhead cupboard HC = garden tap
WITNESS DATE
Maroochydore 07 5444 2521 Daniel.chapman 8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2. 3.9.2 BCA Vol 2. ISSUE/DATE: SHEET
QLD Mobile: @stroudhomes. No.
9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in) 15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
4558 0402 864 305 com.au C 2016 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
ISSUE 2 : 8/01/2021 10 OF 12
GSPublisherVersion 0.0.100.100