Original source · versioned page text
Architecturals 08.01.21
Original PDF page 11, section 1. The text section number identifies this passage in the reader.
28,180
1,670 5,040 9,030 11,990 450
600 9,700 1,690
50
350
2,340
2,340
50 350 4,275 350 4,275 350 50
1,940 50mm STEPDOWN
TO ALFRESCO
1,360
1,470
2,910
1,550
1,906
1,906
1,465
SINK
WASTE
6,470
2,213
670
1,350
4,720
3,670 4,593 BATH SINK
3,505 4,120 WASTE WASTE
565
3,220
2,440
3,350
SHR
900
FLOOR DOES NOT FALL TO WASTE
2,350
4,010
VANITY
5,550
FW FW
1,300
WASTE
WC
VANITY WASTE FLOOR DOES NOT FALL TO WASTE
6,250
3,370
VANITY
WASTE WASTE VANITY
WASTE
1,794
6,970
7,020
1,000
WC
19,550
19,550
1,670 WASTE
SHR 13,530 11,025
12,830 12,085 10,990 10,120 6,350
1,070 10,490
4,580
2,045 1,755
706
3,470
9,660
1,400 31,
1,290
TUB
WASTE
BOLD LINE REPRESENTS THE
EXTERIOR PERIMETER OF THE DWELLING
1,520 450
740
50mm STEPDOWN
1,170
TO PORCH
5,060 OA
350
NOTE:
NO STEPDOWN TO GARAGE
GARAGE DOOR REBATE
80
PLUMBER/DRAINER TO VERIFY ALL DIMENSIONS TIMBER ROLL EGDE
FRAME
PRIOR TO POSITIONING ALL UNDERSLAB POINTS.
6,440
MEASURMENTS MAY VARY. DOOR JAMB DOOR JAMB
6,240
5,060
FLOOR WASTE FIXTURES TO BE POSITIONED
4,860 BRICK
AT THE TIME OF CONSTRUCTION.
4,720
TERMITE PROTECTION:
DETAIL NOT TO SCALE SLAB PLAN
TERMITE PROTECTION IS A VISUAL BARRIER SYSTEM SCALE 1:100
WITH APPROVED COLLARS AT PENETRATIONS IN
ACCORDANCE WITH AS.3600.1 - 2000 470 2,300 470
11,760 3,240 4,670
440
270 6,440 12,230 2,300 5,140 1,350 450
28,180
NOTES PLAN LEGEND CLIENT:
PLEASE READ CAREFULLY
10. Protection against subterranean termites shall be in accordance with AS
THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE
G. LEWIS & S. PAESSEY
1. Written dimensions take precedence over scale. 3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with afl = above floor level ref = refrigerator prov. CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
2. Builder to verify all dimensions and levels prior to commencement of construction. approved collars/barriers at slab penetrations. hd = head at 2100 afl. mw = microwave prov. HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
3. All internal dimensions stated are frame size - excluding linings. 11. HWS unit (constant flow) with 5 star energy efficiency rating to comply fw = floor waste dw = dishwasher prov. OTHER PREVIOUS PLANS OR SKETCHES.
Lot 4, 297 Lawnville Road
4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005. = smoke detector pty = pantry
timber framed construction). 12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC vb = vanity basin wm = washing machine prov. BLACK MOUNTAIN
Stroud Homes Pty Ltd 5. Supplier may substitute lintels for those of equal strength to span ratio. PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003 obs = obscure glazing ghw = gas hot water unit
ABN: 49 107 897 736 QBSA Lic No: 1083367 6. All structural sizes to be read in-conjunction with structural engineers drawings & AS/NZS 6400:2005. mb = meter box tr = towel rail MODEL: JOB
OWNER/S No. 20L297LA
details. 13. Lift off hinges to all WC doors to comply with Australian Standards. dp = downpipe trh = toilet roll holder Montego 329 Skillion
107 Sugar Road Telephone: Email: 7. Articulation joints to complay with 3.3.1.8 BCA Vol 2. 14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt ohc = overhead cupboard HC = garden tap
WITNESS DATE
Maroochydore 07 5444 2521 Daniel.chapman 8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2. 3.9.2 BCA Vol 2. ISSUE/DATE: SHEET
QLD Mobile: @stroudhomes. No.
9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in) 15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
4558 0402 864 305 com.au C 2016 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
ISSUE 2 : 8/01/2021 11 OF 12
GSPublisherVersion 0.0.100.100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.