Architecturals 08.01.21
Original PDF page 12, section 1. The text section number identifies this passage in the reader.
A2 PAGE
DIRECTION Y REQUIRED kN = 105.3
BRACING & TIE-DOWN TIMBER LIST 70mm FRAME - 2700 mm HT MAX - 7.5m RLW MAX GALVANISED LINTEL TABLE BRACING NOTES:
CODE TYPE LENGTH VALUE No. TOTAL MAX. CLEAR GALVANISED (*) BRACING PANELS LESS THAN 900mm WIDE
CLASSIFICATION SPECIFICATION SINGLE STOREY
OPENING (UP TO) LINTEL SIZE TO HAVE 1/M12 ROD AT EACH ENDFULL HEIGHT
A TB4 HARDWOOD PLY [email protected] kN/m 900mm 5.4kN 21 113.40 - REINFORCED CONCRETE SLAB LOAD BEARING NON LOAD BEARING 600mm 85mm x 8mm MULTI RIB FLAT BAR
A TB4 HARDWOOD PLY [email protected] kN/m 500mm 3.0kN
SHEET METAL ROOF - TOP & RIBBON PLATE - TOP PLATE 900mm 85mm x 8mm MULTI RIB FLAT BAR
- PINE TRUSSES, SPACED 2/70 x 35 MGP12 70 x 35 MGP 10 1200mm 100mm x 100mm x 6mm MULTI RIB ANGLE 4.5MM HARDWOOD PLY - METHOD B
B STEEL ANGLE [email protected] kN/m 1800mm 2.7kN WIND CLASS = N3 AT 900 C/C
1500mm 100mm x 100mm x 6mm MULTI RIB ANGLE SHEATHING SHALL BE NAILED TO TOP & BOTTOM
- BOTTOM PLATE - BOTTOM PLATE 1800mm 100mm x 100mm x 6mm MULTI RIB ANGLE
B STEEL ANGLE [email protected] kN/m 2400mm 3.6kN
UPPER / SINGLE STOREY - PINE INTERNAL AND 70 x 35 MGP 12 70 x 35 MGP 10 2100mm 100mm x 100mm x 6mm MULTI RIB ANGLE PLATES & ANY HORIZONTAL JOINTS AT 50MM CTS
METAL ROOF EXTERNAL FRAMING - STUDS AT 450 C/C - STUDS AT 600 C/C 2400mm 100mm x 100mm x 6mm MULTI RIB ANGLE TO COMPLY WITH TABLE 8.18
B STEEL ANGLE [email protected] kN/m 2700mm 4.0kN - METAL TOP HAT CHANNELS 2700mm 150mm x 100mm x 6mm MULTI RIB ANGLE "STRUCTURAL WALL BRACING"
70 x 35 MGP12 70 x 35 MGP 10
UPLIFT LOAD WIDTH = 7867 TO MANUF.SPEC SPACED AT 900 C/C 3000mm 150mm x 100mm x 6mm MULTI RIB ANGLE PAGE 142 SECTION (H) AS1684.2 - 2006
C BRACING BRICK [email protected] kN (both directions) 1.5kN - NOGGINGS - NOGGINGS 3300mm 150mm x 100mm x 6mm MULTI RIB ANGLE
JOINT GROUP = JD4 - LINTELS/BEAMS AS PER TABLE OR 70 x 35 MGP 10 70 x 35 MGP 10 3600mm 150mm x 100mm x 6mm MULTI RIB ANGLE
RES. TIMBER FRAMED CONSTRUCTION
RESISTANCE PROVIDED kN = 113.40 DESIGNED BY TIMBER SUPPLIER MANUAL (PART 2 - NON CYCLONIC)
DIRECTION X REQUIRED kN = 78.00
CODE TYPE LENGTH VALUE No. TOTAL
A TB4 HARDWOOD PLY [email protected] kN/m 900mm 5.4kN 16 86.40
masonry piers
A TB4 HARDWOOD PLY [email protected] kN/m 500mm 3.0kN
B STEEL ANGLE [email protected] kN/m 1800mm 2.7kN
B STEEL ANGLE [email protected] kN/m 2400mm 3.6kN
B STEEL ANGLE [email protected] kN/m 2700mm 4.0kN
C BRACING BRICK [email protected] kN (both directions) 1.5kN 3.0
RESISTANCE PROVIDED kN = 86.40
A0.9 A0.9
TIE DOWN SHEET METAL ROOF
JOINT GROUP = JD4
WIND CLASS = N3
UPLIFT LOAD WIDTH = 8.3m MAX
A0.9
A0.9
A0.9
- TOP PLATE TO M12 RODS AT CORNERS, GIRDER TRUSSES, ROOF
SLAB BEAMS & SIDES OF OPENINGS & THEN AT 1200 CENTERS
30 x 0.8mm G.I. STRAP LOOPED WITH 4 / 2.8mm DIA
A0.9 A0.9
- TRUSS TO TOP PLATE NAILS EACH END + 2 SKEWED NAILS THRU TRUSS
(1200mm centres) TO TOP PLATE
0.9A
0.9A
- METAL BATTENS TO 2 BATTEN SCREWS
TRUSSES TO COMPLY WITH TABLE 9.25
0.9A
"UPLIFT CAPACITY OF ROOF BATTEN
- JD4 TIE DOWN CONNECTION" DETAIL (B)
STRENGTH OF 2.72 kN PAGE 204 AS1684.2-2006
A0.9
MANUAL (PART 2 - NON CYCLONIC) AND
MANUFACTURERS SPECIFICATIONS.
M12 HOLD DOWN BOLTS LOCATED AT 1200mm CTS AND EITHER SIDE
OF BRACING PANELS 0.9A
SINGLE / UPPER STOREY
LINTEL SCHEDULE SHEET METAL ROOF
0.9A 0.9A
A0.9
OPENING RLW = 4500 RLW = 6000 RLW = 7500 0.9A
0.9A
600 mm 90 x 35 90 x 35 90 x 35
900 mm 90 x 35 90 x 35 90 x 35
1200 mm 90 x 35 90 x 35 90 x 35
A0.9
0.9A
0.9A
1500 mm 90 x 45 120 x 35 120 x 35
A0.9
1800 mm 140 x 35 140 x 35 140 x 45
0.9A
A0.9
0.9A
0.9A
0.9A
0.9A
2100 mm 170 x 35 170 x 35 190 x 35 A0.9
2400 mm 170 x 35 190 x 35 170 x 70
0.9A 0.9A 0.9A 0.9A
A0.9
0.9A
2700 mm 190 x 35 170 x 70 190 x 70
ALL LINTELS TO BE MGP.12 - TABLE NOT APPLICABLE FOR ADDITIONAL
ROOF LOADS, SUCH AS GIRDER TRUSSES ETC. 1. This building has been designed in accordance with
AS 1684.2 - 2006 (Residential timber framed construction),
and wind speed N3 (unless otherwise noted)
The wind classification is subject to engineers verification
2. All lintels, floor joists, bearers, trusses & supporting girder
A trusses to be DESIGNED & CERTIFIED by timber supplier.
B B Timber suppiler may substitute lintels nominated on drawings
A for those of equal strength to span ratio.
3. All structural sizes to be read in-conjunction with structural
N3 FRAMING PLAN engineers drawings & details
A0.9
4. Bracing capacity to concrete block walls (where applicable)
SCALE 1:100
0.9A 0.9A
to be confirmed & certified by structural engineer.
NOTES PLAN LEGEND CLIENT:
PLEASE READ CAREFULLY
10. Protection against subterranean termites shall be in accordance with AS
THIS PLAN CERTIFIED CORRECT IS THE ONE REFERRED TO IN THE
G. LEWIS & S. PAESSEY
1. Written dimensions take precedence over scale. 3660-Pt 1 2001. Provided treatment: Visual Barrier System to perimeter with afl = above floor level ref = refrigerator prov. CONTRACT & SPECIFICATIONS AND I UNDERSTAND CHANGES
2. Builder to verify all dimensions and levels prior to commencement of construction. approved collars/barriers at slab penetrations. hd = head at 2100 afl. mw = microwave prov. HEREAFTER MAY NOT BE POSSIBLE. THESE PLANS SUPERCEDE ALL
3. All internal dimensions stated are frame size - excluding linings. 11. HWS unit (constant flow) with 5 star energy efficiency rating to comply fw = floor waste dw = dishwasher prov. OTHER PREVIOUS PLANS OR SKETCHES.
Lot 4, 297 Lawnville Road
4. This building has been designed in accordance with AS 1684.2 - 2006 (Residential with "Sustainable Buildings" QDC pt 29, AS/NZs 6400:2005. = smoke detector pty = pantry
timber framed construction). 12. Rainwater tanks, lighting and plumbing fixtures & fittings to comply with QDC vb = vanity basin wm = washing machine prov. BLACK MOUNTAIN
Stroud Homes Pty Ltd 5. Supplier may substitute lintels for those of equal strength to span ratio. PART 29 & 25, 'Sustainable Buildings' QDC pt 29 & 25 AS/Nzs 300.1.2003 obs = obscure glazing ghw = gas hot water unit
ABN: 49 107 897 736 QBSA Lic No: 1083367 6. All structural sizes to be read in-conjunction with structural engineers drawings & AS/NZS 6400:2005. mb = meter box tr = towel rail MODEL: JOB
OWNER/S No. 20L297LA
details. 13. Lift off hinges to all WC doors to comply with Australian Standards. dp = downpipe trh = toilet roll holder Montego 329 Skillion
107 Sugar Road Telephone: Email: 7. Articulation joints to complay with 3.3.1.8 BCA Vol 2. 14. Stair construction to comply with Pt 3.9.1 and balustrades to comply with pt ohc = overhead cupboard HC = garden tap
WITNESS DATE
Maroochydore 07 5444 2521 Daniel.chapman 8. Mechanical Ventilation to comply with 3.8.5 Bca Vol 2. 3.9.2 BCA Vol 2. ISSUE/DATE: SHEET
QLD Mobile: @stroudhomes. No.
9. Smoke alarms to comply with 3.7.2 BCA Vol 2 (wired-in) 15. DCP & flashings to comply with Pt 3.3.4 BCA Vol 2
4558 0402 864 305 com.au C 2016 REPRODUCTION IN PART OR WHOLE IS STRICTLY FORBIDDEN
ISSUE 2 : 8/01/2021 12 OF 12
GSPublisherVersion 0.0.100.100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.