Damage to Services and Assets
21. Any damage caused to existing services and assets as a result of the
development works must be repaired at no cost to the asset owner at the
following times:
a. where the damage would cause a hazard to pedestrian or vehicle safety,
immediately; or
b. where otherwise, upon completion of the works associated with the
development.
Any repair work which proposes to alter the alignment or level of existing services
and assets must first be referred to the relevant service authority for approval.
Noise
22. Mechanical plant and equipment, a/c units, motors, refrigeration equipment,
compressors, pumps etc on site should be situated within the building or suitably
provided with noise reduction measures and located as to prevent a noise
nuisance beyond the boundary of the site and not exceed the levels specified in
Table 1.
TABLE 1
NOISE LIMITS AT A SENSITIVE RECEPTOR
Noise level at noise sensitive place measured as the adjusted
PERIOD
maximum sound pressure level (L10, adj,T)
7am – 6pm Background noise level (L90,T) plus 5 Db(A)
6pm – 10pm Background noise level plus 5 Db(A)
10pm – 7am Background noise level plus 3 Db(A)
NOISE LIMITS AT A COMMERCIAL PLACE
Noise level at a commercial place measured as the adjusted
PERIOD
maximum sound pressure level (L10, adj,T)
7am – 6pm Background noise level (L90,T) plus 10 Db(A)
6pm – 10pm Background noise level plus10 Db(A)
10pm – 7am Background noise level plus 8 Db(A)
23. When requested by Council, a Noise Impact Assessment Report (NIAR) showing
monitoring and recording of noise levels must be undertaken to investigate any
complaint (other than a frivolous or vexatious complaint) caused by noise
emissions from operations at the premises. Such monitoring must be undertaken
within a reasonable and practicable timeframe nominated by Council and be
performed by a suitably qualified person in accordance with accepted guidelines
and standards. The report must be submitted to Council detailing the results of
such monitoring and recommendations for any measures to achieve compliance
with limits outlined in Table 1 of this Decision Notice.
For the purpose of measuring and certifying relevant noise conditions and
reporting (e.g. mechanical plant and equipment, a/c units, motors, refrigeration
equipment, compressors, pumps, rooftop plant and equipment. Etc) a suitably
qualified person is either: