Council archive · source document
Delegated Report - Code - Planning MCU24 0139 (As Published) · MCU24/0139
Criteria Planning Scheme Proposal Complies
zone other than the contained in the Innovation
Innovation Zone Zone (southern boundary).
Carparking 1 covered space for 1 uncovered X
caretaker (1 space)
1 space per 50m2 for 6 uncovered
Research and office space
(6 spaces) – excludes server,
building services and cooling areas
Motorcycle Spaces 1 space per 100m2 = 4 4 Motorcycle spaces X
Motorcycle spaces (conditioned to be
amended and relocated).
Bicycle Spaces 4 bicycle spaces 4 bicycle spaces
The application has been found to generally comply with all applicable statutory instruments. The
pertinent issues arising out of the assessment are discussed below:
Setbacks - Front and side setbacks
Acceptable Outcome AO8 of the Innovation Zone Code states:
AO8 -Buildings and other structures are set back:
• 6 metres to any road frontage;
• 3 metres to any other boundary unless where adjoining the Environmental
Management and Conservation Zone where the setback is no less than 5 metres
The applicant is proposing a range of building setbacks from 4.5 - 11.6 metres and as such does
not comply with AO8 of the Innovation Zone Code. The proposal is therefore required to comply
with corresponding Performance Outcome PO8 of the Innovation Zone Code, which states:
PO8 Buildings and other structures are appropriately designed and sited to—
a) provide amenity for users of the premises, as well as preserve the visual and acoustic privacy
of adjoining and nearby land uses;
b) provide adequate separation distance from adjoining land uses;
c) allow space for required vehicle parking;
d) allow for landscaping between buildings including the preservation of existing vegetation that
would buffer or complement the proposed building;
e) avoid large areas of continuous wall planes by varying the building setbacks and using
appropriate techniques to provide visual relief.
Assessment
The proposed building encroaches into the front 6.0 metre setback to Rufous Street with a 4.5
metre setback shown for this frontage. The proposal also falls short of the 3.0 metre setback to
‘other boundaries’ with the eastern side elevation setback at 2.0 metres with the roof overhang at
1.75 metres.
The relatively small site area (709m²) combined with the triangular shape of the lot concentrates
the more viable developable portion of the site to its southern extent, which has in part contributed
to the setback non-compliance. The proposed setbacks are reasonable given the site has 2 road
frontages, a wide road reserve to Rufous Street and opportunities for landscaping extending along
the majority of the building street facade.
Page 10 of 25
Document Set ID: 23369912
Version: 4, Version Date: 21/07/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - Planning MCU24 0139 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.