Log in to see the plans as drawn DESIGN IN ACCORDANCE WITH THE QUEENSLAND HOME
BUILDING CODE, AS 1684.2 N3 CLASSIFICATION, BUILDING BRACING DIRECTION B (HOUSE) - 65.80kN
CODE OF AUSTRALIA AND THE STANDARD BUILDING BY-LAWS.
MARK TYPE LENGTH COUNT RESISTANCE
X1 PB 600 2 8
WIND CATEGORY - N3
X2 PB 900 7 40
X3 PB 1200 4 31
BRACING LEGEND : X4 TB 2400 3 11
HARDIBRACE' OR STRUCTURAL PLY BRACING WITHIN
BEAM OVER TO Grand total 90 75x75 SHS CANTILEVERED BEAM OVER
PB ENGINEERS DESIGN POST INSIDE BEAM OVER TO TO ENGINEERS
WALL CAVITY TO MANUF. SPEC. PROVIDE STRUCTURAL
PLY WITH COACH SCREWS FOR CORNER 600 PANELS. WALL ENGINEERS DESIGN DESIGN
6.4 kN/m BEAM OVER BEAM OVER BEAM OVER BEAM OVER BEAM OVER
TB
TECO SPEEDBRACE OR ANGLE BRACE FIXED TO
MANUF. SPECS. 1.5 kN/m
BEAM OVER
BEAM OVER
BEAM OVER
BL
CORE FILLED BLOCK
M12 CYCLONE RODS TO BE AT MAX. 900 crs. X3 X3 X2
AND AT EACH SIDE OF OPENINGS. BEAM OVER
ROOF TO BE BRACED WITH SPEEDBRACE OR Y1 Y1
ANGLE BRACE IN ACCORDANCE WITH TRUSS Y2
Y3
MANUFACTURERS SPECIFICATIONS.
BEAM OVER
BEAM OVER
Y2
Y3
Y2 Y2
W1 W1
Y3
Z1 Y1
X4 Y3
X3 X3
X1 Y2
Y3 X4 X4
75x75 SHS
Z2 POST
Y2 Y2 Y3 INSIDE
Y3 Y3 Y3 WALL
Y4 Y4 Y2
Z2
Y2 Y2
Z2 Y3 Y3 Y3
Z1 Y2
BEAM OVER
W1 W1 X2 X2 X2 X2 X1 X2 X2
NOTE:
BRACING DIRECTION A (CARPORT) - 25.80kN ALL BEAMS, LINTELS, FLOOR FRAMING,
TIE-DOWN, SLAB & FOOTINGS TO
MARK TYPE LENGTH COUNT RESISTANCE BRACING DIRECTION A (HOUSE) - 167.9kN
ENGINEERS DESIGN
Z1 PB 600 2 7.68
Z2 PB 1200 3 23.04 MARK TYPE LENGTH COUNT RESISTANCE NOTE:
ALL BRACING TO CHECKED & SIGNED
Grand total 30.72 Y1 PB 600 3 11.52 OFF BY A QUALIFIED ENGINEER.
FRAMING : N3 Y2 PB 900 11 63.36
Y3 PB 1200 12 92.16
PRE-FAB Y4 TB 2400 2 7.20
BRACING DIRECTION B (CARPORT) - 25.80kN
TRUSSES : PINE ROOF TRUSSES @ 900 CRS
TO MANUF. DESIGN & SPECS. REFER
Grand total 174.24
C & H FRASER
TO CONNECTION DETAILS FOR TIE DOWN MARK TYPE LENGTH COUNT RESISTANCE
DETAILS. ROOF BATTENS FIXED TO TRUSS W1 PB 1200 4 30.72 LOT 21 NO.16 PINES ROAD
AS PER MANUFACTURERS SPECIFICATIONS. COOROY QLD
Grand total 30.72
19.11.2021
BRACING Scale: 1 : 100 Sheet: 10 of 13
as design + drafting 0410 326 991 WD104 - WORKING DRAWINGS