ELECTRICAL
LEGEND

          CEILING FAN                         F         EXHAUST FAN

                                                        SMOKE ALARM
                                                        SINGLE FLURO
          CEILING FAN /
          LIGHT COMBINATION                 MB          METER BOX

                                            HWS         HOT WATER SYSTEM
          HEAT FAN & LIGHT
                                                        SINGLE LIGHT SWITCH
                                                        UNLESS OTHERWISE NOTED,
          LIGHT POINT                                   LOCATE 1100mm ABOVE FL

                                                        DOUBLE LIGHT SWITCH
          DOUBLE GPO                                    UNLESS OTHERWISE NOTED,
          UNLESS OTHERWISE NOTED,                       LOCATE 1100mm ABOVE FL
          LOCATE 300mm ABOVE FL AND
          150mm ABOVE BENCHTOPS                         3 GANG LIGHT SWITCH
                                                        UNLESS OTHERWISE NOTED,
          SINGLE GPO                                    LOCATE 1100mm ABOVE FL
          LOCATE TO SUIT APPLIANCE
                                            WP          WATER PUMP
          TELEPHONE POINT

          TELEVISION POINT                              GHWU - GAS HOT WATER UNIT
          UNLESS OTHERWISE NOTED,
          LOCATE 300mm ABOVE FL




                                                                                    UP




                                                                                                           AC POSITION   ghwu
                                                                                                                                GAS GAS




               NEW DWELLINGS AND DWELLINGS BEING SUBSTAINTIALLY RENOVATED
               From 1 January 2017
               The development approval process for new dwellings and substantial renovations will
               ensure that building approvals received on or after this date will bring dwellings into
               compliance with the new laws.
               Smoke alarms in the dwelling must:
               i) be photoelectric (AS 3786-2014); and
               ii) not also contain an ionisation sensor; and
               iii) be hardwired to the mains power supply with a secondary power source (i.e. battery);
               and
               iv) be interconnected with every other smoke alarm in the dwelling so all activate
               together.
               Smoke alarms must be installed on each storey:
               i) in each bedroom; and
               ii) in hallways which connect bedrooms and the rest of the dwelling; or
               iii) if there is no hallway, between the bedrooms and other parts of the storey; and
               iv) if there are no bedrooms on a storey at least one smoke alarm must be installed in
                                                                                                                                          C & H FRASER
               the most likely path of travel to exit the dwelling.
                                                                                                                                                    LOT 21 NO.16 PINES ROAD
                                                                                                                                                              COOROY QLD

                                                                                                                                                                        19.11.2021
ELECTRICAL PLAN                                                                                                                            Scale:   1 : 100    Sheet:     11   of   13



as design + drafting 0410 326 991                                                                                                                    WD104 - WORKING DRAWINGS
Log in to download the original file

Attachment 2 - Proposal Plans.pdf · 1.0 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.