                      Stormwater Drainage
               16.    The site must be provided with a stormwater drainage system connecting to a lawful point
                      of discharge. The drainage system:
                          a.      must be generally in accordance with drawing number 20625 – H02 Revision DD3
                                  prepared by BRW Hydraulics dated 23 August 2023,
                          b.      must be endorsed through a building permit,
                          c.      must be designed by a suitably qualified person,
                          d.      must be a gravity system only, and
                          e.      must not cause scour or damage to the subject site or any adjoining property.
                      Easements
               17.    Unless otherwise agreed in writing by the relevant service provider, any public or third party
                      infrastructure located on the subject site must be placed within an easement registered
                      against the title of the property.
               18.    All easements must be designed in accordance with the planning scheme and granted at
                      no cost to the Grantee. Where the Grantee is Council or a service authority, the easement
                      documentation must be in accordance with the Grantee’s standard easement terms. Draft
                      easement documentation must be submitted to Council for endorsement.
               19.    All works must be kept clear of any existing or proposed easements on the subject land,
                      unless agreed otherwise in writing by the Grantee.
                      Earthworks and Retaining Walls
               20.    All earthworks and associated retaining structures/batters, both above and below ground,
                      both temporary and permanent, must be contained entirely within the subject site unless
                      written permission from the respective landowner(s) is provided to Council.
               21.    All retaining walls must be designed and constructed in accordance with the planning
                      scheme and must be certified by an RPEQ where exceeding 1.0m in height. All retaining
                      walls that are publicly accessible and exceed 1.0m in height must be fitted with a
                      commercial grade safety fence.
                      Damage to Services and Assets
               22.    Any damage caused to existing services and assets as a result of the development works
                      must be repaired at no cost to the asset owner at the following times:
                          a.      where the damage would cause a hazard to pedestrian or vehicle safety,
                                  immediately; or
                          b.      where otherwise, upon completion of the works associated with the development.
                      Any repair work which proposes to alter the alignment or level of existing services and
                      assets must first be referred to the relevant service authority for approval.
               5.     REFERENCE DOCUMENTS

               Not applicable
               6.     REFERRAL AGENCIES

               Not applicable.
               7.     ADVISORY NOTES

               The following notes are included for guidance and information purposes only and do not form
               part of the assessment manager conditions:
                      Infrastructure Charges


                                                                                                      Page 12 of 13

Document Set ID: 22489647
Version: 8, Version Date: 07/12/2023
Log in to download the original file

Delegated Report - Code - Planning MCU23 0075 [As Published].pdf · 3.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.