Skip to the record
Accept no substitutions.

Council archive · source document

06/2552 NEGOTIATED Decision Notice [As Published] · 132006.2552

of 15

Text shows just the words. Original shows the document exactly as it was published.

NOOSA COUNCIL IDAS Development Application Decision Notice                                                9 of 15


      60.    As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer for
             design intent, and a Licensed Surveyor shall certify the cadastre and the location, level and type of
             all services and structures. All of which shall be submitted to Council for checking and for
             Council’s records.
             The data must fully detail levels for all engineering works including but not limited to drainage
             structures, finished ground levels and pavement surface levels. The data shall be submitted in the
             Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC are
             available at www.adac.com.au).
      61.    Approval of works shall not be granted until all As Constructed information has been supplied and
             accepted by Council.
      Environmental Health
      62.    The developer must provide waste storage and disposal facilities in accordance with Planning
             Scheme Policy No. 9 “Waste Management Multi-Dwellings and Commercial and Industrial
             Premises”, including an external imperviously paved area correctly sized for all refuse and
             recycling containers and suitably screened from public places and neighbouring properties. A bin
             wash area is required with a cold-water tap, hose and drain outlet connected to sewer, via a bucket
             trap. The drain outlet is to be designed to prevent storm water entry to the sewerage system and
             this can be achieved with a nib wall 50mm high and up to 700mm x 700mm wide (max 0.5m²), or
             alternatively the waste area can be roofed, or any other design approved by Council.

      63.    Noise emission from mechanical equipment (air conditioners, refrigeration equipment or pool
             pumps etc) shall comply with the following requirements:
             The equipment shall be installed and located in a manner that prevents excessive noise in
             accordance with Council’s Local Law No. 12 - Control of Nuisances. Infringement Notices (on-the-
             spot fines) may apply for offences.
             A person must not use equipment on any day if it makes or causes noise to be made –
             From 10pm to 7am: More than the lower of either –
                  40 dB(A)

                  3 dB(A) above the background noise level

                  No audible noise for pool pumps apply during these hours.
                    From 7am to 7pm: More than the lower of either –
                  50 dB(A)

                  5 dB(A) above the background noise level
             From 7pm to 10pm: More than 3 dB(A) above the background noise level.
      64.    Submission of written certification from a suitably qualified person confirming that the noise levels
             from all mechanical equipment comply with the cause above when measured at either the
             residential boundary or outside the most exposed part of an affected building, whichever is the
             closest to the equipment.
             The assessment and certification is required immediately after installation of the equipment and
             prior to any occupation of the building, and in a format approved by Council. This assessment
             must take into account noise from any other fixed equipment on the property e.g. swimming pool
             pump, heating/cooling equipment, etc that may increase the overall noise level emitted.

      Advice: It is highly recommended that the person you engage to certify the installation is involved at the
      plan development stage so they can recommend where this equipment is best located. They can also
      advise about noise enclosures and can make other suggestions to avoid noise problems. It is a lot more
      costly to try and deal with noise problems after everything is built.

      Trade Waste
      65.    The hydraulic drawings are to show all the Trade Waste requirements in accordance with the
             Noosa Trade Waste Policy. NB: A Trade Waste Permit must cover all types of Trade Waste
             discharged.

      66.    The Trade Waste application fee of ($105.00) is required at the time of the application.




AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@b808a965\@[email protected]

Used in these records

About this file

File size
65 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

06_2552 NEGOTIATED Decision Notice [As Published].pdf · 65 KB (small file)