Log in to see the plans as drawn Performance Outcomes Acceptable Outcomes
(b) windows and other openings are permanently screened
to a minimum height of 1.7 metres to avoid overlooking;
(c) windows and doors use translucent glazing to obscure
views; or
(d) windows or balconies are offset by 45 degrees or more.
Editor's note—refer to figure AP3-1C
AO78.5
Planter boxes, screens, pergolas, landscaping and
architectural design of balconies are used to screen the ground
floor private open space of dwellings from separate upper-level
dwellings.
AO78.6
Permanently fixed external screening devices complement the
building's external materials and finishes and may incorporate
solid translucent screens, shutters, perforated panels or trellises
which have a maximum of 50% openings.
Editor's note—refer to figure AP3-1B
PO79 AO79.1
Development, including mechanical plant, vehicle manoeuvring Communal outdoor recreational facilities including swimming
and communal outdoor recreation uses: pools, spas and sports courts are:
(a) do not have an adverse effect on the amenity enjoyed by (a) setback at least 12 metres from the boundary of land in a
users of adjacent or nearby premises through emission residential zone and screened by a 5 metre wide buffer
of noise, light, fumes or smoke; densely planted with trees and shrubs including species
(b) do not cause unreasonable disturbance to local fauna from 1 metre to 8 metres in height; or
through light or smoke emissions. (b) located internally to the arrangement of buildings on the
site; and
(c) not used between the hours of 9:00pm and 6:30am the
following day
AO79.2
For a lit sports court:
the court is located at least 60 metres from the external wall of
an existing or approved dwelling on adjoining or nearby
premises (as measured from the centre line of the court); and
the vertical illumination resulting from direct, reflected or other
incidental light emanating from the site does not exceed 8 lux
when measured at any point 1.5 metres outside the boundary
and at any level from ground level upward; and
any flood lighting is restricted to the types that give no upward
component of light where mounted horizontally (i.e. a full cut off
luminare)
AO79.3
Mechanical plant is:
(a) located at least 2 metres from side or rear property
boundary;
(b) where located at ground level, screened by fencing 1.5
metres in height or dense vegetation of at least 1.5
metres in width incorporating grouped trees and shrubs
with maximum separation distance of 1 metre measured
from the centre of the plant;
(c) where located above ground level, enclosed or screened
**FINAL DRAFT - Post Consultation 2019** Page 24 of
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.