Log in to see the plans as drawn erformancePerformance outcomes Acceptable Outcomes
Lighting is directed onto the site and away from neighbouring
properties.
AO44.4
Vandalresistant lighting is used in public and publicly
accessible areas.
Vehicle loading and waste
PO45 AO45
Vehicle loading / unloading and waste storage and collection Vehicle loading/unloading, waste storage/collection and
areas do not significantly impact on the visual or acoustic external storage areas are enclosed within a service yard or
amenity of the area or sensitive landuses. courtyard and located to the rear or under the building and not
located along any frontage to a public street or space.
Table 6.4.3.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
Earthworks and Drainage
PO46 AO46
Filling, excavation and retaining structures do not directly, Filling and excavation works are designed and constructed to
indirectly or cumulatively cause adverse impacts external to the ensure overland flow and/or flooding is not worsened,
development site by: impeded, or otherwise diverted to adversely affect other
(a) causing ponding of water on the site or nearby land; properties and downstream environments.
(b) increasing flooding, which adversely affects the safety or
use of any land upstream and downstream; or
(c) adversely affecting the flow of water in any overland flow
path.
Table 6.4.3.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
Pedestrian and Cycling Connectivity
PO47
Convenient and legible connections are provided for No acceptable outcome provided
pedestrians and cyclists to the site, particularly having regard to
linkages with existing and proposed public transport
infrastructure, the open space network, centres and other
communityrelated activities.
PO48 AO48.1
Public or semipublic spaces are integrated into the centre's Public and semipublic spaces are located to ensure
pedestrian and cycle networks. pedestrian movement flows through the site and connects to
the pedestrian and cycle networks.
AO48.2
Pedestrian arcades, laneways or enclosed thoroughfares are a
minimum of 6 metres wide, provide a direct line of sight to a
major pedestrian destination (major tenancy, car park, public
place, etc.), and are not dead ends, narrow or circuitous.
Table 6.4.3.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
Environment and heritage
PO49 AO49.1
Development: Development does not result in sediment or other material
**FINAL DRAFT Post Consultation 2019** Page 12 of 13
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.