erformancePerformance outcomes Acceptable Outcomes
PO37
Pathways allow clear sightlines in all directions. No acceptable outcome provided
PO38
Adequate lighting is provided to building entrances, carparks No acceptable outcome provided
and pedestrian routes.
Editor’s Note—Applicants may find useful guidance to the
Queensland Government’s Crime Prevention through
Environmental Design Guidelines for Queensland.
PO39 AO39.1
All property boundaries are clearly identifiable with public and Boundaries are identified by such means as:
private spaces clearly defined. (a) fencing;
(b) changes in surface materials or levels; or
(c) landscape treatments.
AO39.2
Loading and storage areas are well lit or can be locked after
hours.
PO40 AO40
All premises and access routes are clearly identifiable to all All premises are identified by the provision of the street number
persons, particularly emergency services personnel. in a prominent location, preferably near the site entry, (i.e. on
the kerb or letterbox or by signage on the building or site).
PO41 AO41.1
Building entries are visible and easily identifiable. The number of entrances and exits are limited and main
building entrances/exits are located at the front of the site in
view of the street or where this is not possible, due to site or
existing building constraints, a welldefined path is provided to
the entrance/exit.
AO41.2
All entrances/exits to buildings, are well lit and signed, and
signage includes hours of operation.
AO41.3
Entrances/exits are located to provide a direct link to driveways
and car parking areas.
AO41.4
Recessed doorways are avoided where the recess is of
sufficient size to conceal a person or where recessed doorways
are unavoidable, the following measures are used to enhance
safety:
(a) good lighting;
(b) strategically placed mirrors;
(c) angled approaches; or
(d) gates which restrict access.
Vandalism
PO42 AO42
Buildings and structures are designed to minimise Buildings or structures that are visible and accessible from a
opportunities for vandalism. public street or laneway:
(a) avoid the use of solid fences and blank walls which
attract graffiti. Where solid blank surfaces are
unavoidable, measures in the form of landscaping,
creepers, murals, vandal resistant paint, etc. are used;
**FINAL DRAFT Post Consultation 2019** Page 10 of 12