      erformancePerformance outcomes                                     Acceptable Outcomes
                                                                         (b)   with windows at ground level use measures that deter
                                                                               break and enters without obscuring views to shopfronts;
                                                                               and
                                                                         (c)   are constructed to be vandal and graffiti proof.

      Lighting
      PO43                                                               AO43.1
      Lighting of appropriate intensities is provided to maximise        Lighting of appropriate intensities is provided which satisfies
      safety.                                                            the requirements of Australian Standard AS1158: Public
                                                                         Lighting Code, unless otherwise specified in this Code.

                                                                         AO43.2
                                                                         External lighting of a graduated intensity is provided which
                                                                         starts at a lower level of brightness at the perimeter of the site
                                                                         and rises to a higher level at the entrance to buildings or at the
                                                                         centre of the site.

                                                                         AO43.3
                                                                         Lighting is directed onto the site and away from neighbouring
                                                                         properties.

                                                                         AO43.4
                                                                         Vandal­resistant lighting is used in public and publicly
                                                                         accessible areas.
      Vehicle loading and waste
      PO44                                                               AO44
      Vehicle loading / unloading and waste storage and collection       Vehicle loading/unloading, waste storage/collection and
      areas do not significantly impact on the visual or acoustic        external storage areas are enclosed within a service yard or
      amenity of the area or sensitive landuses.                         courtyard and located to the rear or under the building and not
                                                                         located along any frontage to a public street or space.

     Table 6.4.4.3 Criteria for assessment (part)
      Performance outcomes                                               Acceptable Outcomes
      Earthworks and drainage
      PO45                                                               AO45
      Filling, excavation and retaining structures do not directly,      Filling and excavation works are designed and constructed to
      indirectly or cumulatively cause adverse impacts external to the   ensure overland flow and/or flooding is not worsened,
      development site by:                                               impeded, or otherwise diverted to adversely affect other
      (a)   causing ponding of water on the site or nearby land;         properties or downstream environments.

      (b)   increasing flooding, which adversely affects the safety or
            use of any land upstream and downstream; or
      (c)   adversely affecting the flow of water in any overland flow
            path.


     Table 6.4.4.3 Criteria for assessment (part)
      Performance outcomes                                               Acceptable Outcomes
      Pedestrian and Cycling Connectivity
      PO46
      Convenient and legible connections are provided for                 No acceptable outcome provided
      pedestrians and cyclists to the site, particularly having regard to
      linkages with existing and proposed public transport
      infrastructure, the open space network, centres and other
      community­related activities.




**FINAL DRAFT ­ Post Consultation 2019**                                                                                             Page 11 of 12
Log in to download the original file

2019-12-11 SM Agenda - Item 1 - Attachment 2 - Final New Noosa Plan Part 1-3 and 5-6 Track Change version(PDF, 4MB).pdf · 3.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.