Council archive · source document
SUPERSEDED Decision Notice - 010.2006.00002689.001 [As Published] · 132006.2689
NOOSA COUNCIL IDAS Development Application Decision Notice 4 of 19
12. The proposed development shall have all kitchen, laundry and bathroom fittings that comply with the AAA
Water Conservation Rating System as defined by the AS/NZS 6400 (Water Efficient Products - Rating
and Labelling 2003) and AS/NZS 3500 (National Plumbing and Drainage Standard Part 1.2), with toilets to
comply with the AAAA Water Conservation Rating System. All tap ware and shower roses shall not
exceed a maximum flow of 9 litres per min. Dishwashers and washing machines are excluded from this
requirement.
13. Security in the form of a cash bond or trading bank guarantee to the sum of $20,000 must be submitted,
to secure performance of all conditions of this approval, prior to the issue of a Development Permit for
Operational Works. The cash bond or trading bank guarantee will be returned on performance of the
conditions of approval less any costs incurred by Council in respect of enforcing performance of this
permit.
14. The requirements of this development approval are to be effected, prior to the use of the premises.
Council reserves the right to call upon the bond or guaranteed sum referred to in this approval to effect
compliance with conditions.
15. The Development Permit for a material change of use of premises lapses if the use has not happened by
1 November 2011, unless an application to extend the currency is approved by Council.
16. The developer must obtain all of the other Development Permits referred to in the Decision Notice, prior to
obtaining a Development Permit for Building Works.
Land Development
Lot Amalgamation
17. All separate, adjoining lots that form part of this application shall be amalgamated into one undivided
allotment in accordance with Section 3.7.3 of the Integrated Planning Act and the Plan of Survey
submitted for registration at the Land Titles Office. Proof of title being issued for the amalgamated lot
shall be submitted to Council prior to the issue of the Development Permit for Operational Works.
Vehicle Access
18. A vehicular access driveway to serve the development shall be constructed from the David Low Way
frontage of the site with a maximum width of 6.0m. The “slip lane” in David Low Way at the entrance to the
site as shown on drawing number 2243 SD03 G dated 6/7/07 prepared by Ken Down Architects shall be
deleted.
19. The driveway shall be designed and constructed to Council’s design standards and to grades that prevent
vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
without any step or level difference. Should any driveways be constructed to grades that do not comply
with AS/NZS 2890.1-2004, Council will require that the driveway be removed and reconstructed to levels
that do comply.
Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
20. To ensure pedestrian safety between vehicles exiting the site and pedestrians on the footpath, the
driveway and any associated fencing or vegetation near the driveway shall comply with the minimum sight
line requirements as defined in AS2890.1, section 3.2.4. The applicant shall demonstrate compliance by
illustrating these sight lines on the plans submitted for both Operational Works approval and Building
Works approval.
21. All vehicles shall enter and leave the site in a forward direction.
Car Parking
22. Carparking shall be provided within the site generally as shown on Basement/Site Plan SD02 Revision F
and Ground Floor SD03 Revision H dated 20 September 2007 as prepared by Ken Down Architects,
except as modified herein.
23. Car parking areas on-site shall be designed to comply with the provisions of AS/NZS 2890.1-2004
including:-
23.1. a minimum of 50 spaces to be designated in the following manner:-
23.1.1. a minimum of 48 spaces designated for car parking including:-
23.1.1.1. a maximum of 18 spaces for staff parking (user class 1);
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@40076eb3\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Decision Notice - 010.2006.00002689.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 283 KB (small file)
- File type
No other editions are linked here.