23.1.1.2. a minimum of 29 spaces for customer parking (user class 3);
23.1.1.3. a minimum of 1 space designated for disabled parking (user class 4) to be
located at the ground floor level;
23.1.2. a minimum of the equivalent of 2 car park spaces for motorcycle and motor scooter
parking, to accommodate a minimum of 5 spaces;
23.2. all client/visitor spaces with allowance for vehicles to enter and leave the site in a forward gear and
with a minimum head clearance (headroom) at any point of 2.2m.
23.3. all disabled car spaces shall be designed with allowance for vehicles to enter and leave the site in
a forward gear and with a minimum head clearance (headroom) at any point of 2.3m.
24. The proposed turning area at the end of the aisle that serves proposed carpark spaces 25 to 34 shall be
line-marked with chevrons and have the words “No Parking” painted on the pavement. A sign shall also
be provided to indicate that the area is a “Turning Area Only” and that “No Parking is Permitted”.
25. An additional turning area shall be provided in the location of proposed carspace 21 as shown on drawing
number 2243 SD02 E dated 3/7/07 as prepared by Ken Down Architects. The turning bay shall be line-
marked with chevrons and have the words “No Parking” painted on the pavement. A sign shall also be
provided to indicate that the area is a “Turning Area Only” and that “No Parking is Permitted”.
26. Additional safety measures shall be placed on and adjacent to the access ramp to the basement
carparking area. The measures shall be generally in accordance with the recommendations of the report
prepared by Burchill VDM Job No:C3694, Report No:4530-0 dated July 2007. In additional to the
measures recommended in the report the applicant shall construct a small median, minimum of 200mm
wide and 150mm high, on the ramp to provide a physical barrier to prevent vehicles straying onto the
wrong side of the ramp.
27. All carparking shall be kept, maintained and line-marked in a condition fit for use.
28. All staff carpark spaces shall be clearly defined by line marking each space with the words “Staff Parking
Only” and by sign posting each space with a similar wording.
29. All disabled carpark spaces shall be clearly defined by line marking each space with the words “Disabled
Parking Only” and by sign posting each space with a similar wording.
Frontage Works
30. Footpath improvements such as topsoiling, grassing, and tree planting are required to the David Low Way
frontage of the site in accordance with Planning Scheme Policy PSP03 Landscaping Plants & Guidelines.
Grass shall be couch, free of weeds.
31. A new 2.0m wide concrete path shall be constructed along the David Low Way frontage of the site in
accordance with Council’s design standards and to an alignment that protects any significant vegetation
or any underground services.
32. All paths, driveways and parking areas shall be designed and constructed to ensure pedestrian safety
using non-slip materials, to produce an evenly graded surface finish, and to be in accordance with the
Disability Discrimination Act 1992 and Australian Standard 1428.1 Design for Access & Mobility.
33. All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel, footpath
paving and landscaping such as trees and grasses in accordance with Council’s Standard specifications
prior to commencement of the use permitted by this permit.
Roof Water & Stormwater Drainage
34. Roof runoff from any new building shall be directed to a rainwater storage system or tank (minimum
2
storage the greater of 5000 litres or 15 litres/m of roof area) that is installed to ensure water from the tank
is used for external uses (such as watering gardens, irrigation, ornamental ponds, water features, outdoor
cleaning, etc) and for use in flushing of toilets internal to the building. All rainwater tanks are to be
designed and installed in accordance with the Queensland Development Code (QDC), Part 25 –
Rainwater Tanks, and shall be part of the plumbing application in conjunction with the building approval.
The location and capacity of the tanks shall be clearly shown on the plans submitted for Building Works /
Operational Works approval and any overflow shall be directed to the stormwater drainage system.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@40076eb3\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Decision Notice - 010.2006.00002689.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 283 KB (small file)
- File type
No other editions are linked here.