Council archive · source document
SUPERSEDED Decision Notice - 010.2006.00002689.001 [As Published] · 132006.2689
NOOSA COUNCIL IDAS Development Application Decision Notice 7 of 19
43. The existing sewer manhole located in the south-west corner of existing lot 2RP903222 (No. 247) to be
removed and existing sewer located along and within the western boundary of adjacent Lot 22P9315 (No.
247) to be abandoned. Consent of adjacent property owners to carry out any necessary works to
abandon sewer required prior to issue of any Decision Notice in respect to Operational Works. All works
to be carried out to the standards and requirements of Council at applicant’s cost.
Town Water Supply
44. The site shall be connected to Council’s existing town water supply and be constructed in accordance with
Council’s standards and requirements at no cost to Council.
45. Each individual water connection to the water reticulation system shall extend to the property boundary
and be metered. All fees for the supply of water meters shall be paid to the Council.
46. All water meters must be located outside the property boundary and in an easily assessable location to
facilitate unhindered reading by Council and/or Council’s contracted water meter readers, and not behind
fences or locked gates. In this regard approval of the water meter configuration and location must be
obtained from Council’s Water & Sewerage Capital Works Manager prior to lodgement and approval of
hydraulic drawings.
47. For Multiple Uses (including Building Format Plans, Group Title Plans, etc) the development shall be
served by:-
47.1. A single Body Corporate water meter to measure the total water consumption (including fire hose
reels, but excluding fire hydrants and fire sprinkler systems), and
47.2. Individual water meters to each tenement capable of being separately rated, and
47.3. A fire service (fully testable single detector check with metered bypass), where applicable, for flows
to fire hydrants and fire sprinkler systems (excluding fire hose reels).
48. The applicant is advised that this development may require the provision of fire hydrants and a booster
pump in accordance with the Building Code of Australia, and consultation may also be needed with
Queensland Fire Services to ensure suitable fire fighting infrastructure is provided. To this end any
necessary fire hydrants shall be clearly shown on the plans submitted for both Operational Works and
Building Works approval and if a booster pump is deemed necessary, the plans shall indicate where the
fire truck is to be accommodated in order to provide boosting to the water supply.
Service Easements (Sewer / Stormwater)
49. A registered easement shall be created over the zone of influence of all sewers within the subject site and
over those parts of the subject site that are impacted upon by sewers on any adjoining sites. The
easements shall generally be parallel to and centred over the sewer main and be equivalent in width to
twice the depth to invert level of the sewer at the deepest point within the allotment (measured from the
finished surface) and be no less than 3.0m wide overall. In this regard a licensed surveyor shall
accurately locate all sewer mains and determine the necessary width of the easement, which shall be
shown on any plans submitted for Operational Works / Building Works approval. To this extent the
surveyor shall certify that the sewer and the zone of influence is wholly contained within the easement to
be created.
In addition to this the Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in
writing that the Title Deed and the easement documents will be lodged at the Land Titles Office and any
additional Titles Office forms or requisitions requiring the consent of Council will be attended to promptly.
A duly executed copy of the easement shall be submitted to Council for perusal prior to the use
commencing.
Any changes required by Council’s Solicitor must be corrected immediately.
50. The applicants to create a private easement for drainage within the adjoining property to the north (Lot 95
SP137431) to enable connection to Council’s existing infrastructure. The easement is to be centrally
located over the pipework with a minimum width of 1.5m or be of sufficient width to ensure that all
associated pits and pipes are wholly contained within the easement. The terms of the easement shall
include the responsibilities on the beneficiaries of the easement to maintain the drainage system so as to
be operational at all times. In this regard the applicant shall provide a letter of authority from the adjoining
property owner granting the easement prior to the issue of any Development Permit for Operational
Works.
51. No building or other structure shall be constructed or encroach over an easement.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@40076eb3\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Decision Notice - 010.2006.00002689.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 283 KB (small file)
- File type
No other editions are linked here.