The bores were drilled with a 4WD ute mounted Jacro 200 drilling rig using continuous flight augers
fitted with a tungsten carbide (TC) bit. Dynamic cone penetrometer (DCP) tests were undertaken
adjacent to the bores, and pocket penetrometer (pp) tests were undertaken on auger cuttings, to
provide an indication of the relative density and strength consistency of the subsurface soils.

The field work was undertaken by experienced geotechnical personnel who logged the bores,
collected samples for visual and tactile assessment and for subsequent laboratory testing. Strata
identification was undertaken through observation of cutting returns and recovered samples. Field
descriptions and samples were checked by a geotechnical engineer, and borehole logs corrected
where appropriate to reflect the available laboratory test results.


Field Work Results: The subsurface conditions encountered in the bores are given in detail on the
attached borehole logs, together with notes defining the classification methods and descriptive terms
used. The depths were measured below existing surface levels at the time of investigation.

In summary, the subsurface conditions encountered in the bores typically comprised very stiff silty
clay. The strength consistency of the silty clay was initially very stiff, grading very stiff to hard with
depth locally.

Groundwater seepage was observed at 2.6 m depth in Bore 5 only. No groundwater seepage was
observed in any of the remaining bores whilst open at the time of drilling. It should be noted however,
that groundwater depths and ground moisture conditions are affected by climatic conditions, soil
permeability, drainage conditions and human influence; and will therefore vary with time.


Laboratory Testing: Shrink-swell index tests were undertaken on ‘undisturbed’ tube samples
recovered from the bores for classification purposes. The results of this testing are summarised in
Table 1 with a material test report attached.

Table 1: Results of Shrink-Swell Index Testing
Bore      Depth               Material         Shrinkage          Swell         Shrink-Swell Index
No.        (m)                                    (%)              (%)             (% per ΔpF)

  1      0.6-0.75            Silty CLAY            2.9              0.2                  1.7

  3      0.7-0.85            Silty CLAY            0.8              0.4                  0.6

  5       0.7-0.9            Silty CLAY            1.5              0.5                  1.0




Proposed Glamping Retreat                                                              211008.01.R.001.docx
332 Eastern Branch Road, Kin Kin                                                                  Dec 2022

Used in these records

About this file

File size
3.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Geotechnical Report_compressed.pdf · 3.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.