Council archive · source document
Geotechnical Report_compressed · MCU22/0052
Page 4 of 8 Comments: Site Classification Site classification of foundation soil reactivity strictly only applies to residential buildings up to two- storeys and to other buildings of similar size, loading and flexibility as defined in accordance with AS 2870. To provide an indication of the reactive surface movements associated with the site, the results of the laboratory testing were input into DP’s in-house program REACTIVE, to calculate the characteristic surface movement (ys) value in general accordance with AS 2870. AS 2870 provides recommended values of change in suction (Δu) and depth of suction (Hs) for major and regional centres throughout Australia. However, more detailed published data by Fox (2000) relating climatic conditions to suction was used for this report. A value of 1.2 pF was adopted for Δu and 1.5 m for Hs in the REACTIVE calculations. This is based on a “wet coastal” climatic zone. The results of the analysis indicate the ys value for the site in its current condition is estimated to be less than 20 mm, consistent with ‘Class S’ (slightly reactive) conditions. The designer will need to consider the effects of any earthworks on the site classification. Where existing site soils of similar reactivity won from excavation are reused as controlled fill, increased ground surface movements of up to 30 mm may result for a full clay fill profile, which is consistent with ‘Class M’ conditions. This is due to the need to consider “uncracked” conditions for the first five years after controlled fill placement or two years after excavation (where the depth of cut exceeds the lesser of 0.25 Hs or 0.5 m). If ‘abnormal’ soil moisture conditions are experienced at the site, the site classification would change to ‘Class P’ (problem site) which would require more extensive foundation works or could result in adverse foundation performance. ‘Abnormal’ soil moisture conditions are defined in AS 2870 (Clause 1.3.3) and in summary comprise: • Recent removal of buildings or structures likely to affect soil moisture conditions; • Unusual moisture caused by drains, channels, ponds, dams or tanks; • Recent removal of large trees; • Growth of trees too close to a structure; • Excessive or irregular watering of gardens adjacent to the structure; • Lack of maintenance of site drainage; • Failure to repair plumbing leaks. It should be noted that no assessment of the effect of soil moisture change by trees has been made in estimating the above ys values (either with respect to the removal of established trees prior to development of building pads, or the proximity of established or new trees to proposed buildings). Reference to the requirements in AS 2870 should be made by the building designer in this regard. It should be further noted that the presence or removal of trees can result in additional surface movement, due to tree-induced suction changes and tree-induced centre heave. Such tree-induced movement is not included in the ys calculations used to classify the site. Proposed Glamping Retreat 211008.01.R.001.docx 332 Eastern Branch Road, Kin Kin Dec 2022
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Geotechnical Report_compressed.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.