Council archive · source document
Geotechnical Report_compressed · MCU22/0052
Page 5 of 8 The above site classification comments assume appropriate site maintenance to ensure suitable footing performance. A copy of QBCC notes about landscape planning and foundation maintenance is attached for information. Foundations It is anticipated that foundations for proposed structures would typically comprise high level footings founded into very stiff natural silty clay and may be designed for an allowable bearing pressure of 150 kPa. The above allowable bearing pressure is based on a factor of safety of 2.5 against bearing capacity failure. Slabs supported on high level foundations should be stiffened to suit the expected ground surface movements. All footing excavations should be inspected and tested by an experienced geotechnical engineer from DP to confirm bearing pressures prior to casting of concrete. Experience indicates that properly designed and constructed high level footings sized using the above allowable bearing pressure are likely to undergo settlements in the order of 1% of the footing width. Further advice should be sought from DP regarding settlements once actual footing configurations and design loads are known. Where footings are located adjacent to underground services, the footings should extend to below invert level for a distance of 1 m out from the trench. Beyond 1 m from the trench, the footings should be taken to below an imaginary line drawn up at 45 degrees from the invert level. These requirements do not override minimum structural footing base levels. Where necessary footings may be made up with mass concrete poured to the underside of footing, or alternatively constructed over excavated pedestals. Alternatively, where development loads exceed the above allowable bearing pressure and estimated settlements, a suitable deep foundation will be required. Bored piles would be considered suitable given the subsurface conditions encountered in the bores. The ultimate geotechnical strength (Rd,ug) of bored piles founding at least four pile diameters into the founding stratum can be calculated using the unfactored, ultimate shaft adhesion and end bearing values given in Table 2. The Rd,ug values given will need to be multiplied by a suitable geotechnical strength reduction factor (Øg) to obtain the design geotechnical strength (Rd,g) of piles. In accordance with AS 2159 (2009) the Øg value must be determined by the designer, but based on the anticipated site, design and installation risk factors, a Ø g value of 0.45 is considered likely for a low redundancy pile system. If working stress methods are used in the pile design, the Rd,ug values given in Table 2 will need to be divided by a factor of safety of 2.5 to calculate the maximum single pile working load. Proposed Glamping Retreat 211008.01.R.001.docx 332 Eastern Branch Road, Kin Kin Dec 2022
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Geotechnical Report_compressed.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.