ORDINARY MEETING MINUTES 21 JUNE 2018
8. Service vehicle movements associated with the approved use (including loading
and unloading) must not occur outside the hours of 6am to 6pm Monday to
Saturday, and not at all on Sundays or public holidays.
Noise
9. External speakers or amplified music are not permitted.
10. Refuse disposal, particularly glass bottles and the like, must be considerate of
noise at all times.
11. Management must ensure patrons leave the premises and street frontage
promptly after nightly closing time and do not mingle or otherwise cause noise
nuisance.
12. Noise emissions from any new air-conditioning and refrigeration equipment
associated with the development shall comply with the following requirements:
a. 7am to 10pm: Background + 5dB(A)
b. 10pm to 7am: Background + 3dB(A)
WASTE
Waste Disposal
13. The developer must provide waste storage and disposal facilities in accordance
with Planning Scheme Policy No. 9 “Waste Management Multi-Dwellings and
Commercial and Industrial Premises”. The facilities must include an external
impervious area correctly sized for all refuse and recycling containers and
suitably screened from public places and neighbouring properties. A bin wash
area is required with a cold-water tap, hose and drain outlet connected to sewer,
via a bucket trap. The drain outlet must be designed to prevent storm water entry
to the sewerage system. This can be achieved with a nib wall 50mm high and up
to 700mm x 700mm wide (max 0.5m²), or alternatively the waste area can be
roofed, or any other design approved by Council.
14. Refuse containers must be provided in accordance with the requirements of the
Environmental Protection (Interim Waste) Regulation 1996 and (Waste
Management) Regulation 2000, for the storage and collection of refuse.
15. Public bins must be provided to reduce littering. All bins provided must be for
refuse and recycling and be decanted into the bulk bins by the site operators.
ENGINEERING
Site Access and Driveways
16. Sealed access driveways must be maintained from Main Street to all parking and
manoeuvring areas of the development.
Car Parking
17. A minimum of 5 car parking spaces must be provided and marked on the site and
made available and accessible at all times while the use is open for business.
The carparking must include in particular:
a. provision of vandal resistant public lighting with intensities to satisfy the
requirements of Australian Standard AS1158: Public Lighting Code
b. 1 disabled parking space/s within the total
c. dimensions, crossfalls and gradients in accordance with the relevant
Australian Standard (AS/NZS2890.1:2004 for staff and customers,
AS/NZS2890.6:2009 for people with disabilities).