RFI - Appendix B- Engineering Response Letter · MCU22/0140

of 2

Text shows just the words. Original shows the document exactly as it was published.

                                                                                                             ingeniir


215101-RFI-01
3 November 2022

Building & Plumbing Services
Noosa Shire Council
PO Box 141
Tewantin QLD 4565
[email protected]


RESPONSE TO INFORMATION REQUEST
APPLICATION NUMBER – MCU22/0140

Proposed Duplexes at 7 Ruby Street Cooroy 4563
Lot 616 on C56014

Please find below and accompanying to this letter documentation comprising a complete response
to the Engineering Items in the Information Request dated 01/09/2022

INFORMATION REQUESTED

    4. Demonstrate how compliance with Performance Outcome PO10 of the Driveways and
       Carparking Code of the Noosa Plan will be achieved by providing swept paths for each of the
       proposed garaged vehicles and visitor space – vehicles must be able to leave, the site in a
       forward gear in a total of 3 movements when all other carparks are occupied.

        It is noted that the application is for multiple dwellings, and the provision of dual access driveways to
        each frontage will enable the development to function as 2 separate dual occupancies. As the
        development will function as a dual occupancy it is deemed that the number of traffic movements
        from each access point to the road network would be far less than that of a single access crossover
        for a 4 unit multiple dwelling. AO10 of the Driveways and Carparking code states that dual
        occupancies are exempt from the requirement to exit in a forward gear and is considered to an
        acceptable outcome for this development due to its dual access points.

        It is also considered that the development complies with PO12, AO12.2 of the Dual Occupancy and
        Multiple Dwelling Code in that each provided access does not service 3 or more households so does
        not have the requirement to exit in a forward gear.

    5. Provide a written copy of Unity Water’s in-principle approval for building over existing sewer
       infrastructure.

        Refer enclosed email from Unitywater dated 14/09/2022 providing in-principle acceptance/no
        objection to building over the existing sewer main.

    6. Provide amended plans showing a new inlet pit to the side of the proposed driveway, having
       the same lintel and kerb inlet configuration as the existing.


                                                 Ingeniir Pty Ltd | 215101-RFI-01
                  ABN: 99 642 485 363 | PO Box 988 Maroochydore QLD 4558 | [email protected] | 0404157187
                                                            Page 1 | 2
Full text of the other 1 page

Page 2

                                                                                                                ingeniir


          Refer revised drawings indicating a new kerb inlet pit and lintel in line with current IPWEAQ
          standards, it is noted that this varies from the current inlet configuration but would provide increased
          capture capacity and be considered an improvement on the existing scenario.

     7. Provide an amended Stormwater Management Plan demonstrating how the proposed
        stormwater arrangement will not create a worsening of off-site conditions.

          Additional field inlet pits have been added to the western boundary to assist in the redirection of
          flows between the buildings. Currently the entire site (with the exception of the existing dwelling’s
          roof water) drains to the West; the development proposes to redirect these flows to the road
          reserves on both frontages of the site which will significantly improve and provide a benefit to the
          neighbours on the western side.

          The development to the East of the site has been approved and is currently under construction with
          the same approach.



If you wish to discuss this matter further, please contact Daniel Kenna.

Yours sincerely,


Daniel Kenna
Beng CPEng MIEAust RPEQ 15522 NER 3133685 EC 66121


for and on behalf of Ingeniir Pty Ltd




                                                    Ingeniir Pty Ltd | 215101-RFI-01
                     ABN: 99 642 485 363 | PO Box 988 Maroochydore QLD 4558 | [email protected] | 0404157187
                                                               Page 2 | 2

Used in these records

About this file

File size
145 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

RFI - Appendix B- Engineering Response Letter.pdf · 145 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.