RFI - Appendix B- Engineering Response Letter · MCU22/0140
ingeniir 215101-RFI-01 3 November 2022 Building & Plumbing Services Noosa Shire Council PO Box 141 Tewantin QLD 4565 [email protected] RESPONSE TO INFORMATION REQUEST APPLICATION NUMBER – MCU22/0140 Proposed Duplexes at 7 Ruby Street Cooroy 4563 Lot 616 on C56014 Please find below and accompanying to this letter documentation comprising a complete response to the Engineering Items in the Information Request dated 01/09/2022 INFORMATION REQUESTED 4. Demonstrate how compliance with Performance Outcome PO10 of the Driveways and Carparking Code of the Noosa Plan will be achieved by providing swept paths for each of the proposed garaged vehicles and visitor space – vehicles must be able to leave, the site in a forward gear in a total of 3 movements when all other carparks are occupied. It is noted that the application is for multiple dwellings, and the provision of dual access driveways to each frontage will enable the development to function as 2 separate dual occupancies. As the development will function as a dual occupancy it is deemed that the number of traffic movements from each access point to the road network would be far less than that of a single access crossover for a 4 unit multiple dwelling. AO10 of the Driveways and Carparking code states that dual occupancies are exempt from the requirement to exit in a forward gear and is considered to an acceptable outcome for this development due to its dual access points. It is also considered that the development complies with PO12, AO12.2 of the Dual Occupancy and Multiple Dwelling Code in that each provided access does not service 3 or more households so does not have the requirement to exit in a forward gear. 5. Provide a written copy of Unity Water’s in-principle approval for building over existing sewer infrastructure. Refer enclosed email from Unitywater dated 14/09/2022 providing in-principle acceptance/no objection to building over the existing sewer main. 6. Provide amended plans showing a new inlet pit to the side of the proposed driveway, having the same lintel and kerb inlet configuration as the existing. Ingeniir Pty Ltd | 215101-RFI-01 ABN: 99 642 485 363 | PO Box 988 Maroochydore QLD 4558 | [email protected] | 0404157187 Page 1 | 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
ingeniir
Refer revised drawings indicating a new kerb inlet pit and lintel in line with current IPWEAQ
standards, it is noted that this varies from the current inlet configuration but would provide increased
capture capacity and be considered an improvement on the existing scenario.
7. Provide an amended Stormwater Management Plan demonstrating how the proposed
stormwater arrangement will not create a worsening of off-site conditions.
Additional field inlet pits have been added to the western boundary to assist in the redirection of
flows between the buildings. Currently the entire site (with the exception of the existing dwelling’s
roof water) drains to the West; the development proposes to redirect these flows to the road
reserves on both frontages of the site which will significantly improve and provide a benefit to the
neighbours on the western side.
The development to the East of the site has been approved and is currently under construction with
the same approach.
If you wish to discuss this matter further, please contact Daniel Kenna.
Yours sincerely,
Daniel Kenna
Beng CPEng MIEAust RPEQ 15522 NER 3133685 EC 66121
for and on behalf of Ingeniir Pty Ltd
Ingeniir Pty Ltd | 215101-RFI-01
ABN: 99 642 485 363 | PO Box 988 Maroochydore QLD 4558 | [email protected] | 0404157187
Page 2 | 2