                      Water & Sewer Connections
               25.    An underground connection to reticulated water and sewerage must be provided to the
                      development site in accordance with the standards and requirements of Northern SEQ
                      Distributor–Retailer Authority (Unitywater).
               26.    A Certificate of Completion from the Northern SEQ Distributor–Retailer Authority (Unitywater)
                      must be submitted to Council that certifies an underground connection to reticulated water
                      and sewerage has been provided to the development site.
                      Weather Protection
               27.    Street awnings must be provided along the full length of the Sunshine Beach Road and
                      Berrima Row frontages as shown on the approved plans. The awnings must have a minimum
                      width of 3.2 metres from the building line unless otherwise approved, and must be designed
                      to provide continuous solar and rain protection and promote all weather activity.
                      Public Safety
               28.    All ground floor shopfront glazing must be protected against vandalism by the use of a form
                      of safety glass such as toughened or laminated glass.
               29.    During operating hours, all parking areas, pedestrian areas and entrances/exits to all
                      stairwells, lifts, foyers and public toilets must be well lit with vandal resistant lighting and with
                      intensities to satisfy the requirements of Australian Standard AS1158 “Public Lighting Code”.
                      Lighting must be designed to reduce the contrast between shadows and well lit areas. In
                      particular, appropriate security lighting must be provided in the location of the bicycle/ scooter
                      parking and bin storage area.
               30.    After hours access to loading docks, storage areas and the basement carpark (including the
                      vehicle ramp and all stairwells) must be restricted by a security gate, lockable doors and/or
                      other suitably appropriate means. The basement carpark must be kept closed and locked at
                      all times while the use is not operating.
                      Community Management Statement
               31.    Any proposed Community Management Statement required for the development pursuant to
                      the Body Corporate and Community Management Act 1997 must be submitted to Council for
                      endorsement at the same time as submission of the Building Format Plan (or similar) to
                      Council for compliance assessment.
               32.    All clauses and by-laws of the proposed Community Management Statement must accord
                      with the requirements of this Decision Notice.
                      Site Access and Driveways
               33.    A sealed access driveway must be provided from Berrima Row to all parking and
                      manoeuvring areas of the development. The works must be undertaken in accordance with
                      an Operational Works approval and must include in particular:
                      a.      a driveway crossover generally in accordance Council’s standard drawing RS-051and
                              respective addendum;
                      b.      a driveway crossover generally in accordance with SCG’s plan 30292-C2, titled
                              “Driveway Access Plan”, dated November 2020;
                      c.      suitable safety measures, including warning signage, to improve driver awareness of
                              pedestrians and enhance pedestrian safety. Warning signage must be provided near
                              the exit ramp from the underground parking area to warn motorists of pedestrian
                              movement along the frontage street;
                      d.      the footpath’s section of the driveway must be the same colour as the existing footpath
                              (i.e. terracotta or similar).




                                                                                                            Page 4 of 11
Document Set ID: 21417355
Version: 6, Version Date: 18/03/2021                                                                    Print Date: 18 March 2021, 4:14 PM

Log in to download the original (210319_approval.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.