Council archive · source document
Appendix A - Code Assessment · MCU22/0207
walkways) and boat ramps are not located within
the Noosa Waters Estate.
Flooding and amenity functions - operational works within Noosa Waters Estate waterways
PO23 AO23.1 Not applicable
The flood detention and amenity functions of the For premises adjoining a waterway within the Development is not within the Noosa Waters
area adjacent to the revetment wall within Noosa Noosa Water estate, no building work, filling or Estate waterways.
Waters Estate are retained and enhanced by excavation works within 4.5 metres of the centre
ensuring— line of the top of the concrete revetment wall.
1. works do not protrude through a batter
line of 1:4.5 measured from the centre
line of the revetment wall;
2. there is no additional load placed on the AO23.2 Not applicable
revetment wall; A minimum of 25% of the area within 4.5 metres Development is not within the Noosa Waters
3. works do not pose a risk to the of the revetment wall is planted with shrubs and Estate waterways.
membrane adjoining the revetment small trees with a mature height of 3 metres or
wall; less.
4. amenity of the waterway and
surrounding land uses is not adversely
affected by development (building,
filling or excavation) ensuring—
a) the 4.5 metre setback area is AO23.3 Not applicable
predominantly soft The ground surface within the first metre of the Development is not within the Noosa Waters
landscaping; revetment wall— Estate waterways.
b) dominant impervious areas
and masonry retaining walls 1. is grass or ground cover; and
are avoided; 2. does not include shrubs.
c) retaining structures and the
like are light weight, low rise
and screened by landscaping;
See the original