Original source · versioned page text
2022-06-13 General Committee Meeting Agenda PUBLIC
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
GENERAL COMMITTEE MEETING AGENDA 13 JUNE 2022
Road Traffic Noise
24. Design and construct all residential dwellings to achieve design internal noise levels of AS
2107:2016 “Recommended Design Sound Levels and Reverberation Times for Building
Interiors” as provided in Section 4.4 of the approved Acoustic Logic report dated 23.09.21.
25. Building façade and roof construction is to achieve the acoustic ratings as required in Section
6.1 Tables 19 and 20 and Appendix A, Section 6.2 and Section 6.3 of the Approved Acoustic
Report (Acoustic Logic Report dated 23.09.21).
26. Sealing of Window frames in the external façade is to comply with Section 6.4 of the
Approved Acoustic Report (Acoustic Logic report dated 23.09.21).
27. Provide mechanical ventilation or air-conditioning to all road traffic noise affected rooms as
identified in Section 6.5 and Appendix C of the Approved Acoustic Report (Acoustic Logic
Report dated 23.09.21)
28. Provide certification from an appropriately qualified acoustic consultant prior to Certificate of
Classification that the residential buildings have been constructed in accordance with the
requirements of the Approved Acoustic Report (Acoustic Logic report dated 23.09.21) and
the measured internal noise levels in respect to road traffic noise comply with the
AS2017:2016 levels in Section 4.4 of the approved acoustic report.
29. Provide certification from an appropriately qualified consultant that mechanical ventilation or
air-conditioning has been installed in all habitable rooms affected by road traffic noise as
identified in Section 6.5 and Appendix C of the Approved Acoustic Report (Acoustic Logic
Report dated 23.09.21).
Mechanical Plant Noise
30. Design and install all mechanical plant as part of the development to comply with Section 7.1
and Table 22 of the Approved Acoustic Report (Acoustic Logic Report dated 23.09.21)
31. Provide certification from an appropriately qualified acoustic consultant prior to Certificate of
Classification that the mechanical plant has been installed with the requirements of the
Approved Acoustic Report (Acoustic Logic report dated 23.09.21) and the measured noise
levels of operational plant comply with Table 22 of the Approved Acoustic Report (Acoustic
Logic Reported dated 23.09.21).
ENGINEERING/TRAFFIC
External Works
32. Hofmann Drive must be upgraded for the length of its frontage to the subject site. The works
must be undertaken in accordance with an Operational Works approval, completed prior to
the commencement of the use and must include in particular:
a. construction of a pedestrian footpath in accordance with the conditions of this Decision
Notice
b. removal of all existing property access (driveway/crossovers) and reinstatement of the
kerb, footpath and verge area to match the balance of the site frontage, including the
provision of topsoil and turf where the existing verge is grassed
Site Access and Driveways
33. A sealed access driveway must be provided from the formation in Hofmann Drive to all
parking and manoeuvring areas of the development. The works must be undertaken in
accordance with an Operational Works approval and must include in particular:
a. a driveway crossover generally in accordance with Council standard drawing RS-051
and any associated addendums
b. access aisles and ramps in accordance with AS/NZS2890.1:2004 Parking Facilities
Car Parking, Pedestrian and Bicycle Facilities
Page 10 of 69
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.