Working Drawings- September 21
Attached to the e-mail Email with further plans.msg.
Original PDF page 1, section 1. The text section number identifies this passage in the reader.
a
LEGEND - INTERNAL
GENERAL NOTES WIND CATEGORY - N2 AP - APPLIANCE CUPBOARD
BC - BROOM CUPBOARD
1. ALL MATERIALS SHALL BE NEW.
AHD RL / m 9.429
TBM Nail in Kerb
C'BD - CUPBOARD
2. FOOTING: TO ENGINEER DETAILS. DP - DOWNPIPE
FOOTINGS TO HAVE SOLID BOTTOMS SITE COVER DW - DISHWASHER PROV.
AND EVEN BEARING THROUGHOUT. FW - FLOOR WASTE
3. SLAB: TO ENGINEER DETAILS SITE AREA : 971.00 m² GAS - GAS CONNECTION
UNDERLAY WITH 200mm POLYTHENE
WATERPROOF MEMBRANE AND ALL
DWELLING SITE COVER : 36.46 % ( 354.03 m²) HP - HOT PLATE
N
- WERIN ST -
HWS - HOT WATER SYSTEM
PROTRUSIONS. CAST ON 50mm SAND OUTDOOR AREA SITE COVER : 9.87 % ( 95.81 m²) L - LINEN
9.28
9.43
BEDDING ON APPROVED FILL. MH - MANHOLE
TOTAL SITE COVERAGE : 46.33 % ( 449.84 m²)
Gutterline
CONCRETE STRENGTH TO BE 20MPa MW - MICROWAVE PROV.
Gutterline
AT 28 DAYS. USE TERMITE CONTROL OHC - OVERHEAD CUPBOARD
Asbestos
9.36
PTY - PANTRY
Existing
AS PER BUILDERS SPECIFICATIONS.
Highset
Brick &
House
4. TIMBER FRAMING: ALL FIXINGS AS
PER CONNECTION DETAILS AND GOOD 9.32
CORROSION RESISTANCE: R - ROBE
REF - REFRIDGERATOR SPACE
WORKMANSHIP. RH - RANGEHOOD
5. LININGS: AS PER BUILDERS SPECIFICATIONS. 9.40 9.57
NOTE: DWELLING TO COMPLY WITH CORROSION PROTECTION SH - SHELF
REQUIREMENTS OF BCA FOR LESS THAN 200mm FROM SALTWATER TR - TOWEL RAIL
9.
6. ROOFING: COLORBOND METAL SHEET 9.7
9.5
77
TRH - TOILET ROLL HOLDER
ROOFING OR CONCRETE ROOF TILES 9. 0 5 OF NCC VOL.2 TABLE 3.4.4.2 & 3.5.1.1a, AS3700 & AS4773 UBO - UNDER-BENCH OVEN
OVER AN APPROVED SARKING MATERIAL 25 Concrete Driveway
Outlet IL 9.01
Roofwater
AND FIXED IN ACCORDANCE WITH THE WO - WALL OVEN
MANUFACTURERS SPECIFICATIONS. LEGEND - EXTERNAL
RL 9.55
Sewer M/H
9.
7. PLUMBER AND DRAINER: TO LOCAL
74
9.16 9.30 9.54 BV - BRICK VENEER
AUTHORITY REGULATIONS.
9.18
LOW HEIGHT SLEEPER RETAINING WALLS CJ - CONTROL JOINT
9.
?
8. ELECTRICIAN: TO LOCAL AUTHORITY
70
FC - FIBRE CEMENT SHEETING
REGULATIONS. AS REQUIRED ON-SITE 9.5 RH - RENDERED HEBEL PANELS
No Mk 7
Found 9. Meter
9. BRICKLAYER: GALVINISED WALL TIES 0 RBB - RENDERED BLUEBOARD
9.10
1 ROW AT 2 COURSES ABOVE FLASHING
9.
9.
RB - RENDERED BRICKWORK
9.
OPEN ENTRY
9.
9. 9.4
11
06
9.
76
LINE AND 1 ROW IN THE SECOND LAST 9.75
44
62
RBL - RENDERED BLOCKWORK
65
9.00 ARBOUR
9.
BED JOINT FROM TOP OF WALL [email protected]
SA - SCYON AXON
44
90°0'
60
02
59
37
Power Pole
500crs. IN BETWEEN ON EACH STUD. 9.70 9.68 9.69 9.68 9.71 9.64 9.70
9
?
1
9.70 9.37 SL - SCYON LINEA
# 307278
0
PROVIDE WEEP HOLES @ 900crs. ALONG 9. 9.19 SM - SCYON MATRIX PANELING
9.05 9.08 9.67
9.48
9.32 9.34 9.40 9.29
3000 WALL
Ac
41.219
6
00
FLASHING.
17
9.
No Mk
W SS - SCYON STRIA CLADDING
Found
16
c
Gully
9.2
8.
08
8.9 ess
8.
10. ALL WET AREA FLOOR AND SHOWER FLOORS
Tap
Water
81
5 WB - HARDIES NEWPORT
94
9.
3
TO COMPLY WITH B.C.A. SECTION 3.8.1.
1040
24
8.62
9.
GATEHOUSE ACCESS PATH
PROPOSED
8.
17
8.85
79
LETTERBOX
8.80
Post
NOTE : BUILDER TO CHECK AND CONFIRM ALL 1009
Picket & Wire Fence
POOL
8100 GARAGE
9.
Post
8.85
MEASUREMENTS PRIOR TO COMMENCEMENT
18
POWDERCOATED POOL STYLE FENCING GATE AS
8.
8.8
8.75
85
PROPERTY
8.
OF CONSTRUCTION. DO NOT SCALE DRAWINGS, SPECIFIED
8.
1
8.
77
96
96
WRITTEN DIMENSIONS TAKE PRECEDENCE AT 9.0
9.
8.81
BIN ENCLOSURE
DESCRIPTION
8.
9.
18
ALL TIMES. STORMWATER THROUGH P.V.C.
7
0
68
26
PIPE TO LOCAL COUNCIL REGULATIONS. 8.77 8.80
LOT 1 SP
Fence
Start
1200
9.51
8.
Steps LOCAL NOOSA
8.
2
8.
88
84
81
8.
14
8.
8.50
8.
83
COUNCIL : SHIRE
87
9.50 8.7
60
8.5
8.62
8.
8.
5 AREA : 971m²
Porch
38
77
3
8.
8.
91
PROPOSED
8.
84
73
8.
8.50 8.7 8.50
80
27.359
POOL
UP
RL 8.36
Sewer M/H
0
8.
180°0'
15
57
Laundry
8.25
8.
4104 WALL ISSUE
RL 9.67
Floor Level
8.
83
8.
19.735
8.2
8.
8.
61
.
56
41
5
33
33
8.50
Timber & GI
00°0'
8
5
8.
# DATE DETAILS See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of sections 2 to 5 (of 34)
Section 2
BY
30
Existing
Highset
8.4
House
3504 EAVE
8.
8.2 - 21-09-19 INCOMPLETE DC
8.
9
8.
PROPOSED
32
12 8
02
Well Away
8.00
Fibro & GI
5 8.00 - 26-09-18 PRELIM ISSUE DC
4
Existing
8.
House
2
8.36 - 23-10-18 WD ISSUE DC
LETTERBOX UNIT 2
8.0
9.40 7.95
8.0 8.13
8.
2484 UP E 18-06-19 SITE REV DC
0
3
7.90
23
8
Steps
9
7.
7.75 F 09-06-21 PRE-CONTRACT
7.75
77
7.50
7.70
LIFT 9.38 7.83 7.50
PROPOSED - - - -
7.
7.35
(Not Accessable)
65
Thick Vegetation
7.25 7.25 - - - -
DN
7.
10
40
7.
UNIT 1
7.00
7.
7.00 - - - -
78
7.7
78
5
6.
6.75 6.75
7.
91
7.
52
Deck
DN
PAD 6.59
19
6.50
6.
3744 UPPER WALL
31
6.
7.
6.25
89
7.
13
61
6.
64
6.00
29
4194
11
7.50
5.
5.75
96
po box 6384 p (07) 5442 6413
5.
57
CARPORT 5.50 maroochydore f (07) 5450 6437
5.18
7.25 5.25 qld 4558 QBCC 1083000
7.
12
6.
6.
4.
5.00
14
63
5.
85
4.75
5.
This plan remains copyright to
17
7.00 4.50
09
3
7.0 4 .9 2
Ausmar Group and may not be
4.56 4.75
6.
7
?
27
used in part or in whole without
12
4.50
4.
6. 6.75 the written consent of the author.
32
86
4.25
No Mk
Found
LL
1639
6.
© 2017 Ausmar Group
WALL
6.
34
6.50
4.
62
4.00
4.9
3.
1626 WA
(Not Accessable)
07
Thick Vegetation
79
8
6.25 3.75 WRITTEN DIMENSIONS TO
6.00 41.923 3.50 TAKE PRECEDENCE OVER SCALE
1531
EAVE
2.
82
5.75 4. 3.25
3.00 SITE PLAN
2.
9
5.50 6 280°29
1662
94
WALL
5.3 5.0 '
5 5.0 2 2.75
18
5.2
5
0 2.50
2.25
PROJECT DESCRIPTION:
2.00
1.
73
1.75 Proposed Duplex For:
1.
1.50
75
1.
CLIENT:
48
? Searched
MR K ANSCHAU
1.
50
No Mk
21
19
SITE ADDRESS:
LOT 1 WERIN ST
20
TEWANTIN
DESIGNED BY REDDOOR
CUSTOM
DRAWN BY D CARTER
SCALE JOB CODE
1 : 200
DATE
09-06-21
D-KA
SHEET 1 OF 33
Section 3
FLOOR AREAS LEGEND - INTERNAL
UNIT 1 WINDOW SCHEDULE DESIGN IN ACCORDANCE AS 1684.2 N3 CLASSIFICATION AP - APPLIANCE CUPBOARD
GROUND FLOOR AND THE BUILDING CODE OF AUSTRALIA Unit 1 - Alfresco 23.00 m² BC - BROOM CUPBOARD
C'BD - CUPBOARD
Unit 1 - Carport 109.09 m² DP - DOWNPIPE
NO. SIZE Unit 1 - Deck 20.29 m² DW - DISHWASHER PROV.
FW - FLOOR WASTE
U1-W2 2240PLD Unit 1 - Ground Floor 67.61 m² GAS - GAS CONNECTION
HP - HOT PLATE
U1-W3 820 Unit 1 - Porch 3.13 m² HWS - HOT WATER SYSTEM
U1-W4 SD2124-2/2112AWxx Unit 1 - Upper Floor 148.05 m² L - LINEN
MH - MANHOLE
U1-W5 2109AW Unit 1 - Void 3.83 m² MW - MICROWAVE PROV.
U1-W6 2109AW 90 70 OHC - OVERHEAD CUPBOARD
90 Unit 2 - Alfresco 20.84 m² PTY - PANTRY
2480 1610 190 7950 3380 630 530 3580
U1-W7 1215SW Unit 2 - Deck 20.00 m² R - ROBE
REF - REFRIDGERATOR SPACE
U1-W8 0421FG 70 Unit 2 - Drying Court 6.81 m² RH - RANGEHOOD
3935 120 4625 3280 150 3960 1200 SH - SHELF
Unit 2 - Ground Floor 64.43 m² TR - TOWEL RAIL
Unit 2 - Porch 4.16 m² TRH - TOILET ROLL HOLDER
190 1420 3935 4625 90 1310 70 1135 2385 70 2490 UBO - UNDER-BENCH OVEN
Unit 2 - Upper Floor 197.92 m² WO - WALL OVEN
Unit 2 - Void 4.23 m² LEGEND - EXTERNAL
C A
2000h GROUT-FILLED 200 SERIES BLOCK RETAINING Grand total 693.38 m² BV - BRICK VENEER
WALL IN ACCORDANCE WITH ENGINEER DESIGN CJ - CONTROL JOINT
16 15 FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
90
RBL - RENDERED BLOCKWORK
1240
42x42 LOSP PRE-PRIME PINE. SCREEN SA - SCYON AXON
860
WITH 100mm SPACINGS ON ALUM. FRAME. SL - SCYON LINEA
U1-W8 SM - SCYON MATRIX PANELING
190
SS - SCYON STRIA CLADDING
90
90x90 SHS SUPPORT COLUMN
WB - HARDIES NEWPORT
SH
1800h GROUT-FILLED 200 SERIES BLOCK RETAINING
UP
WALL IN ACCORDANCE WITH ENGINEER DESIGN POOL POOL PUMP
M/S 2.0
WALL IN ACCORDANCE WITH
2140
ROBE
OVER
5190
SERIES BLOCK RETAINING
1800h GROUT-FILLED 200
U1-W7
BED 3
3240
3850
3680
ENGINEER DESIGN
3760
7575 75 7575 75
70
187 187 187
187 187
V
470 1030
O
I
D
120x120 SHS COLUMN
70 70
820
PL DUCT
U1-W6
190 1020 190
820
120
LETTERBOX
90
LNDY
LIFT DOOR
1740
ISSUE
1200
1200
LIFT LINE OF FLOOR OVER
UP # DATE DETAILS BY
A/C UNIT WM
GHWU
- 21-09-19 INCOMPLETE DC
PROV
2680
- 26-09-18 PRELIM ISSUE DC
70
B B - 23-10-18 WD ISSUE DC
CARPORT LINEN
820
820
1230
1230
E 18-06-19 SITE REV DC
15 15
980
F 09-06-21 PRE-CONTRACT
10000h GROUT-FILLED
200 SERIES BLOCK
820 BATH - - - -
U1-W5
90
820
2820
RETAINING WALL IN - - - -
1000
U1-W3
800
ACCORDANCE WITH L.CHUTE - - - -
ENGINEER DESIGN TRH
1500
6770
70
400H X 1500W SHAMPOO TR
5570
NICHE. 1100 FROM FLOOR
70
3500
3500
U1-W2
4190 SMARTWASTE
M/S 2.4
ROBE
po box 6384 p (07) 5442 6413
2540
maroochydore f (07) 5450 6437
qld 4558 QBCC 1083000
120x120 SHS COLUMN WITH 35mm This plan remains copyright to
FRAMING ATTACHED. FC PAINTED Ausmar Group and may not be
SH
CLADDING. used in part or in whole without
90
the written consent of the author.
4330
BED 2 © 2017 Ausmar Group
865
120
120
WRITTEN DIMENSIONS TO
TAKE PRECEDENCE OVER SCALE
35
35
42x42 LOSP PRE-PRIME PINE. SCREEN 42x42 LOSP PRE-PRIME PINE. SCREEN
3090
3090
WITH 100mm SPACINGS ON ALUM. FRAME. WITH 100mm SPACINGS ON ALUM. FRAME. UNIT 1 - GROUND
2225
90
PROJECT DESCRIPTION:
600
U1-W4
Proposed Duplex For:
UNIT 1
UNIT 2
CLIENT:
C A
MR K ANSCHAU
16 15
90 90 70 70 90 SITE ADDRESS:
1710 11360 970 1180 2490
LOT 1 WERIN ST
120 120 70
4465 6755 530 4180
TEWANTIN
DESIGNED BY REDDOOR
1700 11460 600 350 3660 350
CUSTOM
NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS DRAWN BY D CARTER
: SMOKE ALARMS TO BE HARD WIRED IN SCALE JOB CODE
ACCORDANCE WITH B.C.A. 3.7.2. 1 : 100
: FLOOR WASTE POSITIONS ARE INDICATIVE DATE
09-06-21
D-KA
ONLY. FINAL POSITIONS TO BE DETERMINED BY
LOCAL AUTHORITY PLUMBING REGULATIONS SHEET 2 OF 33
Section 4
FLOOR AREAS LEGEND - INTERNAL
UNIT 1 WINDOW SCHEDULE DESIGN IN ACCORDANCE AS 1684.2 N3 CLASSIFICATION AP - APPLIANCE CUPBOARD
UPPER FLOOR AND THE BUILDING CODE OF AUSTRALIA Unit 1 - Alfresco 23.00 m² BC - BROOM CUPBOARD
18120 C'BD - CUPBOARD
Unit 1 - Carport 109.09 m² DP - DOWNPIPE
NO. SIZE 90 90 90 90 Unit 1 - Deck 20.29 m² DW - DISHWASHER PROV.
FW - FLOOR WASTE
U1-W9 2400x1500 HINGED 1710 2889 2241 2080 560 3380 630 4180 90 Unit 1 - Ground Floor 67.61 m² GAS - GAS CONNECTION
HP - HOT PLATE
U1-W10 1806AW Unit 1 - Porch 3.13 m²
90 HWS - HOT WATER SYSTEM
U1-W10 820. 90 2700 90 9170 1090 440 2560 Unit 1 - Upper Floor 148.05 m² L - LINEN
MH - MANHOLE
U1-W11 1806AW Unit 1 - Void 3.83 m² MW - MICROWAVE PROV.
70 OHC - OVERHEAD CUPBOARD
U1-W12 2400x4360 FG/FG/FG/AWxx 1800 LIFT 8770 3190 1090 930 2000 Unit 2 - Alfresco 20.84 m² PTY - PANTRY
U1-W13 2400x7300SGD XXXO Unit 2 - Deck 20.00 m² R - ROBE
REF - REFRIDGERATOR SPACE
U1-W14 SD2124-2/2112AWxx/0636FG Unit 2 - Drying Court 6.81 m² RH - RANGEHOOD
OVER C A Unit 2 - Ground Floor 64.43 m²
SH - SHELF
TR - TOWEL RAIL
U1-W15 2109AW 16 15 Unit 2 - Porch 4.16 m² TRH - TOILET ROLL HOLDER
U1-W16 0624SW UBO - UNDER-BENCH OVEN
Unit 2 - Upper Floor 197.92 m² WO - WALL OVEN
U1-W17 2400x820 Unit 2 - Void 4.23 m² LEGEND - EXTERNAL
U1-W18 2406FG
DRYING Grand total 693.38 m² BV - BRICK VENEER
90
2335
U1-W19 2418FG CJ - CONTROL JOINT
FC - FIBRE CEMENT SHEETING
380 277
SAFETY RAILING
U1-W20 2440SGD COURT
GLASS POOL FENCING
RH - RENDERED HEBEL PANELS
90
170
RBB - RENDERED BLUEBOARD
U1-W21 2416FG RB - RENDERED BRICKWORK
90
90
U1-W22 24075AW TAP RBL - RENDERED BLOCKWORK
SA - SCYON AXON
U1-W23 24075AW U1-W17 SL - SCYON LINEA
U1-W18
U1-W23
U1-W22
SM - SCYON MATRIX PANELING
U1-W36 24075AW
2280
DN
STUDY POOL M.P.R SS - SCYON STRIA CLADDING
4380
2040
U1-W45 0642FG. WB - HARDIES NEWPORT
U1-W16
3100
3100
3000 CEILING ALFRESCO 3000 CEILING
4310
4390
PERGOLA OVER
70
820.
198 262 262 262
M/H
262 262 262
DN180
555x555
U1-W9
M/S 2.9
U1-W19
1830
ENTRY
70 70
110
P.
530
420
A/C STORE
810
DN70 MIN
U1-W21 U1-W20 A/C ROOF UNIT 1000
190
1040
90
400H X 1640W SHAMPOO
1640
NICHE. 1100 FROM FLOOR
1020
LIFT DOOR.
LIFT TRH
DN
550 600
VELUX SKYLIGHT SMARTWASTE ISSUE
2950
TR600
190
980x550 # DATE DETAILS BY
70
B B
U1-W10
- 21-09-19 INCOMPLETE DC
1020 C/S
820
- 26-09-18 PRELIM ISSUE DC
8040
15 A/C RETURN AIR 420 15
70
- 23-10-18 WD ISSUE DC
13660
718
E 18-06-19 SITE REV DC
ENS
U1-W15
70 70 90
1720
FW
TAP F 09-06-21 PRE-CONTRACT
400 570
70
6000
LC SMARTWASTE - - - -
REF
FIREPLACE
LIVING DINING - - - -
1280
A/C F'S BATH
300
- - - -
C'BD
70 70
190
3000 CEILING 2700 CEILING
B/BAR
HP/UBO
KIT
70
1218 PLANTATION SHUTTERS
717
ROBE
M/S 2.2
2300
DW PLASTERBOARD NICHE
70
1200 A.FL., 600h x 260d
U1-W11
PROV po box 6384 p (07) 5442 6413
BULKHEAD OVER
820
maroochydore f (07) 5450 6437
MW PTY qld 4558 QBCC 1083000
PROV
90
BED 1
600 310
This plan remains copyright to
670 330
4330
Ausmar Group and may not be
1045
90
used in part or in whole without
U1-W12 U1-W13 the written consent of the author.
3000 CEILING
© 2017 Ausmar Group
2437
DP100 DP100
90 799
WRITTEN DIMENSIONS TO
DECK
1437
2850
TAKE PRECEDENCE OVER SCALE
DP100
UNIT 1 - UPPER
90
90
90 90
510
DP100 U1-W14
DP100
DP100 DP100 PROJECT DESCRIPTION:
150 "D" GUTTERS Proposed Duplex For:
UNIT 1
UNIT 2
100Ø DOWNPIPES
CLIENT:
C
A MR K ANSCHAU
16
15
SITE ADDRESS:
90 70 70 70 90 90 90 LOT 1 WERIN ST
380 10575 805 530 1090 1020 1890
270 270 70 TEWANTIN
1260 270 4370 5461 1039 770 4180
DESIGNED BY REDDOOR
90 POST 90 POST 350
CUSTOM
270 4910 3525 3615 3660 350 DRAWN BY D CARTER
NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS
: SMOKE ALARMS TO BE HARD WIRED IN SCALE JOB CODE
1 : 100
ACCORDANCE WITH B.C.A. 3.7.2.
: FLOOR WASTE POSITIONS ARE INDICATIVE DATE
09-06-21
D-KA
ONLY. FINAL POSITIONS TO BE DETERMINED BY
LOCAL AUTHORITY PLUMBING REGULATIONS SHEET 3 OF 33
Section 5
LEGEND - INTERNAL
UNIT 2 WINDOW SCHEDULE DESIGN IN ACCORDANCE AS 1684.2 N3 CLASSIFICATION FLOOR AREAS AP - APPLIANCE CUPBOARD
GROUND FLOOR AND THE BUILDING CODE OF AUSTRALIA Unit 1 - Alfresco 23.00 m² BC - BROOM CUPBOARD
POOL Unit 1 - Carport 109.09 m²
C'BD - CUPBOARD
DP - DOWNPIPE
NO. SIZE DW - DISHWASHER PROV.
U2-W1 820 OVER Unit 1 - Deck 20.29 m² FW - FLOOR WASTE
GAS - GAS CONNECTION
Unit 1 - Ground Floor 67.61 m²
HP - HOT PLATE
U2-W2 3/2109AW Unit 1 - Porch 3.13 m² HWS - HOT WATER SYSTEM
U2-W3 SD2118-2/2109AWxx Unit 1 - Upper Floor 148.05 m²
L - LINEN
MH - MANHOLE
U2-W4 1806AW. Unit 1 - Void 3.83 m² MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
Unit 2 - Alfresco 20.84 m² PTY - PANTRY
R - ROBE
Unit 2 - Deck 20.00 m² REF - REFRIDGERATOR SPACE
Unit 2 - Drying Court 6.81 m² RH - RANGEHOOD
1200 190 SH - SHELF
Unit 2 - Ground Floor 64.43 m² TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
Unit 2 - Porch 4.16 m² UBO - UNDER-BENCH OVEN
D E F Unit 2 - Upper Floor 197.92 m² WO - WALL OVEN
Unit 2 - Void 4.23 m² LEGEND - EXTERNAL
16 17 17 BV - BRICK VENEER
Grand total 693.38 m² CJ - CONTROL JOINT
FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
GROUT-FILLED 200 SERIES BLOCK RETAINING RBB - RENDERED BLUEBOARD
WALL IN ACCORDANCE WITH ENGINEER DESIGN RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
SA - SCYON AXON
SL - SCYON LINEA
GROUT-FILLED 200 SERIES BLOCK RETAINING SM - SCYON MATRIX PANELING
LINE OF FLOOR OVER WALL IN ACCORDANCE WITH ENGINEER DESIGN SS - SCYON STRIA CLADDING
WB - HARDIES NEWPORT
2950
GARAGE
OVER
90
400H X 1300W SHAMPOO
2950
NICHE. 1100 FROM FLOOR
CUT BATTER ISSUE
B B # DATE DETAILS BY
CLOTHESLINE A/C UNIT
POOL PUMP - 21-09-19 INCOMPLETE DC
15 15
- 26-09-18 PRELIM ISSUE DC
90
90
90
DN - 23-10-18 WD ISSUE DC
GHWU
830
830
1000 TR600 L.CHUTE VOID E 18-06-19 SITE REV DC
1300
F 09-06-21 PRE-CONTRACT
70
770
BATH
1500
2620
2440
1000 - - - -
U2-W4
- - - -
1300
SMARTWASTE UP - - - -
820
70
3390
70
770
WM LINEN
1420
PROPOSED UNIT 1
DRYING PROV WM TAPS
LINE OF FLOOR OVER
IN C'BD po box 6384 p (07) 5442 6413
1740
1780
maroochydore f (07) 5450 6437
COURT LNDY
U2-W1
qld 4558 QBCC 1083000
70
820
530
ROBE This plan remains copyright to
70
70
820 820 Ausmar Group and may not be
9240
used in part or in whole without
1000
the written consent of the author.
© 2017 Ausmar Group
70
WRITTEN DIMENSIONS TO
BED 3 TAKE PRECEDENCE OVER SCALE
3520
3340
BED 2 UNIT 2 - GROUND
4100
M/S 2.1
ROBE
2270
PROJECT DESCRIPTION:
90 70
90
420
Proposed Duplex For:
530
600
600
U2-W2 C'BD
160
CLIENT:
90 90
760
510
PL DUCT
MR K ANSCHAU
600
D U2-W3
16
F
UNIT 2 - GROUND FLOOR
SITE ADDRESS:
17
70 70 90 LOT 1 WERIN ST
90 2820 1450 3040
1 : 100 90 70 TEWANTIN
600 2220 2370 2120 5125
DESIGNED BY REDDOOR
70 70
CUSTOM
NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS DRAWN BY D CARTER
90 3550 530 3230 2473 90 2473 90
: SMOKE ALARMS TO BE HARD WIRED IN SCALE JOB CODE
ACCORDANCE WITH B.C.A. 3.7.2. 1 : 100
: FLOOR WASTE POSITIONS ARE INDICATIVE
ONLY. FINAL POSITIONS TO BE DETERMINED BY
DATE
09-06-21
D-KA
LOCAL AUTHORITY PLUMBING REGULATIONS
SHEET 4 OF 33