Working Drawings- September 21
Attached to the e-mail Email with further plans.msg.
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
90 90 LEGEND - INTERNAL
UNIT 2 WINDOW SCHEDULE DESIGN IN ACCORDANCE AS 1684.2 N3 CLASSIFICATION
6070 830 100 2990 5145 AP - APPLIANCE CUPBOARD
AND THE BUILDING CODE OF AUSTRALIA
UPPER FLOOR BC - BROOM CUPBOARD
70 C'BD - CUPBOARD
DP - DOWNPIPE
NO. SIZE 90 5980 90 1560 400 1890 2455 90 2210 90 DW - DISHWASHER PROV.
300 FW - FLOOR WASTE
U2-W5 2400x1500 HINGED 70 GAS - GAS CONNECTION
U2-W6 2448PLD 90 5980 530 200 760 2290 90 5055 90 HP - HOT PLATE
HWS - HOT WATER SYSTEM
U2-W7 21045 AW GAS 45kg L - LINEN
TAP MH - MANHOLE
U2-W8 21045 AW
30
MW - MICROWAVE PROV.
D POOL F OHC - OVERHEAD CUPBOARD
150
90
90
U2-W9 3/2109AW
390
PTY - PANTRY
U2-W10 SD2118-2/2109AWxx/0627F 16 17 R - ROBE
1465
G OVER 2 REF - REFRIDGERATOR SPACE
RH - RANGEHOOD
2205
2205
2205
2035
U2-W11 ASD2142-3/0642FG OVER STUDY DP100 SH - SHELF
U2-W16
TR - TOWEL RAIL
U2-W12 2109AW
U2-W15
TRH - TOILET ROLL HOLDER
750
U2-W13 2109AW UBO - UNDER-BENCH OVEN
WO - WALL OVEN
4470
150
U2-W14 ASD2142-3/0642FG OVER
4080
70
70
820 LEGEND - EXTERNAL
5100
5100
U2-W15 24075FG
G P. G BV - BRICK VENEER
CJ - CONTROL JOINT
U2-W16 24075AW
U2-W5
FC - FIBRE CEMENT SHEETING
2105
2125
2125
U2-W17 0618FG. 18 ENT ALFRESCO
18 RH - RENDERED HEBEL PANELS
2885
685 4800 595 RBB - RENDERED BLUEBOARD
U2-W18 0627FG. RB - RENDERED BRICKWORK
U2-W19 0627FG. 2700 CEILING 106 4200 839 RBL - RENDERED BLOCKWORK
4025
SA - SCYON AXON
140 140
70 70
U2-W20 0618FG SL - SCYON LINEA
630
630
630
560
420
U2-W6 LINEN U2-W14 SM - SCYON MATRIX PANELING
SS - SCYON STRIA CLADDING
90
90
NICHE. 1500x420 DP100 WB - HARDIES NEWPORT
690
1200 2/620 2400 HEAD HEIGHT
1200
820
U2-W13
2/620 LINE OF SLAB/TIMBER FLOOR
900
70
70
3335
680
PTY
680
680
LINEN BC
@ 2700 HEAD
70
70
TAP
2/620 620
LIVING
1040
U2-W17
REF
6080
5900
5900
70
1000
GARAGE 3000 CEILING
DP100
STORE
140x31 HARDWOOD DECKING
825
V/S 3.6
3880
1640
KIT ISSUE
4800
2770
B/BAR
# DATE DETAILS BY
@ 2700 HEAD
FIREPLACE
U2-W18
1280
2700 CEILING - 21-09-19 INCOMPLETE DC
20330
M/H
555x555 LINE OF SLAB/TIMBER FLOOR MW PROV - 26-09-18 PRELIM ISSUE DC
B B
- 23-10-18 WD ISSUE DC
11600
11780
8550
15 15 E 18-06-19 SITE REV DC
825
90
90
A/C ROOF UNIT F 09-06-21 PRE-CONTRACT
450291
600
L.C DP100 - - - -
U2-W7
830
1000 DW PROV - - - -
70
620 500 - - - -
@ 2700 HEAD
M.P.R
1600
U2-W19
1300
3500
3500
2000
DN
2700 CEILING VELUX SKYLIGHT
2600
980x550
1230 70
70
1020h PLASTERED WALL po box 6384 p (07) 5442 6413
maroochydore f (07) 5450 6437
820
U2-W8
FLOOR AREAS
1230
5335
PROPOSED UNIT 1
qld 4558 QBCC 1083000
450
PROVIDE MECH VENT
Unit 1 - Alfresco 23.00 m²
TO ATMOSPHERE A/C RETURN AIR DINING DP100
This plan remains copyright to
70 70 70
70
110 70
Ausmar Group and may not be
Unit 1 - Carport 109.09 m² 3000 CEILING
350
400H X 1430W SHAMPOO
7790
530
1430 AC used in part or in whole without
@ 2700 HEAD
ROBE
70 1000
NICHE. 1100 FROM FLOOR
U2-W20
930
Unit 1 - Deck 20.29 m² the written consent of the author.
U2-W12
TRH © 2017 Ausmar Group
1890
Unit 1 - Ground Floor 67.61 m² M/S 2.1
900
SMARTWASTE
V/S 2.2
ROBE
770 350 WRITTEN DIMENSIONS TO
Unit 1 - Porch 3.13 m² 70 TAKE PRECEDENCE OVER SCALE
Unit 1 - Upper Floor 148.05 m²
1310
70
BED 1
740
TR600
UNIT 2 - UPPER
70 70
4130
Unit 1 - Void 3.83 m²
ENS DP100
450 350
350
90
AC
Unit 2 - Alfresco 20.84 m² 2700 CEILING U2-W11
450
4290
4290
FW
Unit 2 - Deck 20.00 m²
SMARTWASTE 600h PLASTERED SHELF PROJECT DESCRIPTION:
Unit 2 - Drying Court 6.81 m²
2600
BULKHEAD OVER @ 1200h
1300
1300
Unit 2 - Ground Floor 64.43 m² Proposed Duplex For:
3450
Unit 2 - Porch 4.16 m² 820
4 SHELVES
DECK CLIENT:
70
90
Unit 2 - Upper Floor 197.92 m² MR K ANSCHAU
760 90530
600
DP100 U2-W9 C'BD
Unit 2 - Void 4.23 m²
DP100
90
Grand total 693.38 m²
760
510
U2-W10
1754
90
SITE ADDRESS:
LOT 1 WERIN ST
UNIT 2 - UPPER FLOOR
DP100
70 70 90 TEWANTIN
1 : 100 2560 90 3110 1060 3210 5055
DESIGNED BY REDDOOR
70 70 70 70 70
CUSTOM
NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS 90 1430 1610 530 1340 720 1470 5055 DRAWN BY D CARTER
: SMOKE ALARMS TO BE HARD WIRED IN SCALE JOB CODE
ACCORDANCE WITH B.C.A. 3.7.2. 70 1 : 100
90 3050 90 1010 3230 90 5125
: FLOOR WASTE POSITIONS ARE INDICATIVE DATE
09-06-21
D-KA
ONLY. FINAL POSITIONS TO BE DETERMINED BY
320
LOCAL AUTHORITY PLUMBING REGULATIONS 2560 3230 990 320 2770 5125 SHEET 5 OF 33