Working Drawings- September 21
Attached to the e-mail Email with further plans.msg.
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
LEGEND - INTERNAL
UNIT 2 WINDOW SCHEDULE DESIGN IN ACCORDANCE AS 1684.2 N3 CLASSIFICATION FLOOR AREAS AP - APPLIANCE CUPBOARD
GROUND FLOOR AND THE BUILDING CODE OF AUSTRALIA Unit 1 - Alfresco 23.00 m² BC - BROOM CUPBOARD
POOL Unit 1 - Carport 109.09 m²
C'BD - CUPBOARD
DP - DOWNPIPE
NO. SIZE DW - DISHWASHER PROV.
U2-W1 820 OVER Unit 1 - Deck 20.29 m² FW - FLOOR WASTE
GAS - GAS CONNECTION
Unit 1 - Ground Floor 67.61 m²
HP - HOT PLATE
U2-W2 3/2109AW Unit 1 - Porch 3.13 m² HWS - HOT WATER SYSTEM
U2-W3 SD2118-2/2109AWxx Unit 1 - Upper Floor 148.05 m²
L - LINEN
MH - MANHOLE
U2-W4 1806AW. Unit 1 - Void 3.83 m² MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
Unit 2 - Alfresco 20.84 m² PTY - PANTRY
R - ROBE
Unit 2 - Deck 20.00 m² REF - REFRIDGERATOR SPACE
Unit 2 - Drying Court 6.81 m² RH - RANGEHOOD
1200 190 SH - SHELF
Unit 2 - Ground Floor 64.43 m² TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
Unit 2 - Porch 4.16 m² UBO - UNDER-BENCH OVEN
D E F Unit 2 - Upper Floor 197.92 m² WO - WALL OVEN
Unit 2 - Void 4.23 m² LEGEND - EXTERNAL
16 17 17 BV - BRICK VENEER
Grand total 693.38 m² CJ - CONTROL JOINT
FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
GROUT-FILLED 200 SERIES BLOCK RETAINING RBB - RENDERED BLUEBOARD
WALL IN ACCORDANCE WITH ENGINEER DESIGN RB - RENDERED BRICKWORK
RBL - RENDERED BLOCKWORK
SA - SCYON AXON
SL - SCYON LINEA
GROUT-FILLED 200 SERIES BLOCK RETAINING SM - SCYON MATRIX PANELING
LINE OF FLOOR OVER WALL IN ACCORDANCE WITH ENGINEER DESIGN SS - SCYON STRIA CLADDING
WB - HARDIES NEWPORT
2950
GARAGE
OVER
90
400H X 1300W SHAMPOO
2950
NICHE. 1100 FROM FLOOR
CUT BATTER ISSUE
B B # DATE DETAILS BY
CLOTHESLINE A/C UNIT
POOL PUMP - 21-09-19 INCOMPLETE DC
15 15
- 26-09-18 PRELIM ISSUE DC
90
90
90
DN - 23-10-18 WD ISSUE DC
GHWU
830
830
1000 TR600 L.CHUTE VOID E 18-06-19 SITE REV DC
1300
F 09-06-21 PRE-CONTRACT
70
770
BATH
1500
2620
2440
1000 - - - -
U2-W4
- - - -
1300
SMARTWASTE UP - - - -
820
70
3390
70
770
WM LINEN
1420
PROPOSED UNIT 1
DRYING PROV WM TAPS
LINE OF FLOOR OVER
IN C'BD po box 6384 p (07) 5442 6413
1740
1780
maroochydore f (07) 5450 6437
COURT LNDY
U2-W1
qld 4558 QBCC 1083000
70
820
530
ROBE This plan remains copyright to
70
70
820 820 Ausmar Group and may not be
9240
used in part or in whole without
1000
the written consent of the author.
© 2017 Ausmar Group
70
WRITTEN DIMENSIONS TO
BED 3 TAKE PRECEDENCE OVER SCALE
3520
3340
BED 2 UNIT 2 - GROUND
4100
M/S 2.1
ROBE
2270
PROJECT DESCRIPTION:
90 70
90
420
Proposed Duplex For:
530
600
600
U2-W2 C'BD
160
CLIENT:
90 90
760
510
PL DUCT
MR K ANSCHAU
600
D U2-W3
16
F
UNIT 2 - GROUND FLOOR
SITE ADDRESS:
17
70 70 90 LOT 1 WERIN ST
90 2820 1450 3040
1 : 100 90 70 TEWANTIN
600 2220 2370 2120 5125
DESIGNED BY REDDOOR
70 70
CUSTOM
NOTE : PROVIDE LIFT OFF HINGES TO W.C. DOORS DRAWN BY D CARTER
90 3550 530 3230 2473 90 2473 90
: SMOKE ALARMS TO BE HARD WIRED IN SCALE JOB CODE
ACCORDANCE WITH B.C.A. 3.7.2. 1 : 100
: FLOOR WASTE POSITIONS ARE INDICATIVE
ONLY. FINAL POSITIONS TO BE DETERMINED BY
DATE
09-06-21
D-KA
LOCAL AUTHORITY PLUMBING REGULATIONS
SHEET 4 OF 33