Original source · versioned page text
Working Drawings- September 21
Attached to the e-mail Email with further plans.msg.
Original PDF page 8, section 1. The text section number identifies this passage in the reader.
LEGEND - INTERNAL
SELECT METAL ROOF SHEET SCYON AXON 133 SMOOTH AP - APPLIANCE CUPBOARD
CLADDING. PAINT FINISH. JAMES BC - BROOM CUPBOARD
(TRIMDECK PROFILE) @ 5.0° ON COLORBOND PARAPET CAPPING C'BD - CUPBOARD
ENGINEER DESIGNED TRUSSES HARDIE 9mm ALUMINIUM DP - DOWNPIPE
SELECT METAL FASCIA AND EXTERNAL CORNER (#305521) DW - DISHWASHER PROV.
FW - FLOOR WASTE
GUTTER AND JAMES HARDIE 9mm GAS - GAS CONNECTION
600 O'HANG HARDWOOD PERGOLA ALUMINIUM INTERNAL CORNER HP - HOT PLATE
STRUCTURE. MEMBER SIZES (#305520) HWS - HOT WATER SYSTEM
POWDERCOATED ALUM. RAILING TO TO BE CONFIRMED L - LINEN
MH - MANHOLE
RETAINING FOR FALL PREVENTION
1050
FLAT COLORBOND SHEET OVER MW - MICROWAVE PROV.
OHC - OVERHEAD CUPBOARD
SCYON SECURA BASE SHEET PTY - PANTRY
R - ROBE
550
REF - REFRIDGERATOR SPACE
12.860 RL RH - RANGEHOOD
SELECT FEATURE TILE FINISH SH - SHELF
OVER 190 SERIES BLOCKWORK TR - TOWEL RAIL
TRH - TOILET ROLL HOLDER
WB WB UBO - UNDER-BENCH OVEN
3000 CEILING
WO - WALL OVEN
2400 JOINERY
SA133 150x75 HARDWOOD FRAMEWORK LEGEND - EXTERNAL
POLYCARB. SHEET ROOF OVER BV - BRICK VENEER
CJ - CONTROL JOINT
FC - FIBRE CEMENT SHEETING
RH - RENDERED HEBEL PANELS
LETTERBOX
RBB - RENDERED BLUEBOARD
RB - RENDERED BRICKWORK
9.820 RL RBL - RENDERED BLOCKWORK
9.440 RL SA - SCYON AXON
SL - SCYON LINEA
SM - SCYON MATRIX PANELING
SS - SCYON STRIA CLADDING
WB - HARDIES NEWPORT
JAMES HARDIE PRIMELINE
"NEWPORT" CLADDING. PAINTED 42x42 LOSP PRE-PRIME PINE. SCREEN
FINISH. JAMES HARDIE GAS 45kgWITH 100mm SPACINGS ON ALUM. FRAME.
ALUMINIUM SNAP ON CORNER
(#305513)
UNIT 1 - LEFT ELEVATION
1 : 100
ISSUE
# DATE DETAILS BY
- 21-09-19 INCOMPLETE DC
JAMES HARDIE PRIMELINE - 26-09-18 PRELIM ISSUE DC
COLORBOND PARAPET CAPPING
"NEWPORT" CLADDING. PAINTED - 23-10-18 WD ISSUE DC
FINISH. JAMES HARDIE E 18-06-19 SITE REV DC
SELECT METAL ROOF SHEET ALUMINIUM SNAP ON CORNER F 09-06-21 PRE-CONTRACT
(TRIMDECK PROFILE) @ 5.0° ON (#305513) - - - -
ENGINEER DESIGNED TRUSSES - - - -
600 O'HANG - - - -
SELECT METAL FASCIA AND
GUTTER
WB WB po box 6384 p (07) 5442 6413
maroochydore f (07) 5450 6437
300
4440 PARAPET
11.810 RL qld 4558 QBCC 1083000
SA133 This plan remains copyright to
Ausmar Group and may not be
2700 CEILING
used in part or in whole without
2100 JOINERY
the written consent of the author.
© 2017 Ausmar Group
WRITTEN DIMENSIONS TO
GAS 45kg TAKE PRECEDENCE OVER SCALE
N.G.L.
9.070 RL ELEVATIONS
SCYON AXON 133 SMOOTH 150x50 HARDWOOD POSTS POWDERCOATED ALUM. RAILING TO
CLADDING. PAINT FINISH. JAMES ON GALV. BRACKET RETAINING FOR FALL PREVENTION PROJECT DESCRIPTION:
HARDIE 9mm ALUMINIUM
Proposed Duplex For:
EXTERNAL CORNER (#305521)
AND JAMES HARDIE 9mm CLIENT:
ALUMINIUM INTERNAL CORNER MR K ANSCHAU
(#305520)
SITE ADDRESS:
LOT 1 WERIN ST
UNIT 2 - LEFT ELEVATION TEWANTIN
DESIGNED BY REDDOOR
1 : 100
CUSTOM
DRAWN BY D CARTER
SCALE JOB CODE
1 : 100
ALL FIXING AND FLASHING TO BE IN STRICT ACCORDANCE WITH THE DATE
09-06-21
D-KA
MANUFACTURERS DETAILS. WINDOW SIZES SHOWN ARE NOMINAL ONLY AND
ARE TO BE VERIFIED BY THE BUILDER ON SITE. SHEET 8 OF 33