Skip to the record
Accept no imitations.

Original source · versioned page text

Other Change Decision Notice - Council Meeting Decision 131998 981211 5

of 21

Page text shows just the words. Original shows the document exactly as it was published.

                        Fencing to Protected Land
                85.     A permanent fence or permeant markers must be constructed along the entire length of
                        the interface of the site with the vegetation protection covenants. The fence / markers
                        must be constructed in accordance with an Operational Works approval and must be to
                        the following specifications:
                        a.      allow adequate clearance at ground level for local macropods
                        b.      not include any use of barbed wire or similar materials
                        c.      constructed of fire-proof materials
                        Fauna Management
                86.     Vegetation must only be removed or disturbed in accordance with a Fauna Management
                        Plan (or part thereof) prepared by a qualified person* and endorsed through an
                        Operational Works approval.
                        *(Refer to Advisory Note)
                        Bushfire Management
                87.     The development must be carried out in accordance with Bushfire Hazard Assessment
                        and Management Plan v4 prepared by North Coast Environmental Services dated
                        06/09/2024, which must be amended to include:
                        a.      Revised plans that incorporate the latest architectural plans that show the
                                clamping infrastructure wholly outside of the Noosa plan Bushfire hazard mapping
                                potential impact buffer.
                        b.      Section 5.3 Water Supply is to be updated to include a minimum of 20,000 litres
                                of dedicated static water supply for firefighting purposes for each group of 7
                                cabins. The last paragraph of this section needs to be updated as an error is
                                present “shared between 2 cabins’ This should read 7.
                        c.      Revised plans that demonstrate a minimum 10,000 litres of dedicated static water
                                supply for firefighting purposes is available at the shelter in place location.
                        d.      Revised plans that incorporate the recommended fire access trail within Lot 394
                                M371117 (see Plate 23 of the Bushfire Hazard Assessment and Management
                                Plan) and extending along the southern boundary until it meets the eastern
                                boundary of the subject site, before gaining access to Road 176.
                        e.      Detail that the fire access trail along the southern boundary is to be gated and
                                used for emergency access only.
                        The report must be resubmitted and approved by Council incorporating the above
                        amendments prior to the issue of any Development Permit for Operational Works.*
                88.     The development must be carried out in accordance with Bushfire Evacuation Plan v4
                        prepared by North Coast Environmental Services and dated 06/09/2024, which must be
                        amended as follows
                        a.      Revised plans that that incorporate the latest architectural plans that shows the
                                internal evacuation route that connects directly between the shelter in place
                                building and the clamping infrastructure.
                        b.      Section 8 Evacuation Triggers, to be updated to include:
                                i.      Daily review of FDR forecasts for the Southeast Coast which are available
                                        from the Bureau of Meteorology
                                ii.     Evacuation of all guests and non-essential staff prior to the commencement
                                        of any day with a forecast FDR rating of Extreme or Catastrophic.




                                                                                                       Page 12 of 21
Document Set ID: 23418211
Version: 10, Version Date: 02/01/2025
Log in to download the original file

Other Change Decision Notice - Council Meeting Decision 131998 981211 5.pdf · 214 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.