Performance outcomes                       Acceptable outcomes                                              Response      Comment
                                              event, including consideration of the capacity of the
                                              route to support the evacuation of the entire local
                                              population within a reasonably short timeframe (for
                                              example, 12 hours).
                                           AND

                                           AO2.3 Development within a coastal hazard area is                             Refer above. The proposed development will not result in
                                           located, designed and constructed to ensure exposed                            structures being located in areas subject to flooding from a
                                           structures can sustain flooding from a defined storm tide                      defined storm tide event.
                                           event.
                                           AND

                                           AO2.4 Essential community service infrastructure is:             N/A           The proposed development does not include any essentially
                                           (1) located so that it is not inundated by a recommended                       community service infrastructure.
                                               storm tide event specified for that infrastructure, or
                                           (2) located and designed to ensure any components of
                                               the infrastructure that are likely to fail to function or
                                               may result in contamination when inundated by a
                                               storm tide (for example, electrical switch gear and
                                               motors, water supply pipeline air valves) are:
                                                (a) located above the peak water level for a
                                                     recommended storm tide event, or
                                                (b) designed and constructed to exclude storm tide
                                                     intrusions or infiltration (including by being
                                                     located in the ground), or
                                                (c) able to temporarily stop functioning during a
                                                     recommended storm tide event without causing
                                                     significant adverse impacts to the infrastructure
                                                     or the community.
                                           AND
                                           AO2.5 Emergency services infrastructure and emergency            N/A           The proposed development does                 not    include   any
                                           shelters, police facilities, and hospitals and associated                      emergency services infrastructure.
                                           facilities have an emergency rescue area above the peak
                                           water level for a recommended storm tide event.
PO3 Development directly, indirectly and   AO3.1 Development avoids increasing the number of                             Refer above. The proposed development will not result in an
cumulatively avoids an unacceptable        premises from which people would need to be evacuated                          increase in the number of premises from which people will
increase in the severity of the coastal    to prevent death or injury from a defined storm tide event.                    need to be evacuated from a defined storm tide event.
hazard, and does not significantly                                                                                        In this regard, whilst a Flooding Impact Assessment has not
increase the potential for damage on the                                                                                  been prepared in relation to the subject land, the Proposal
premises or to other premises.                                                                                            Plans included at Appendix B of this report clearly
                                                                                                                          demonstrate that the proposed residential allotments and


State development assessment provisions                                    Module 10 — Coastal protection              10.1 Tidal works, or development in a coastal management district state code
20 June 2014 V1.4                                                                                                                                                                Page 2 of 16

Used in these records

About this file

File size
87 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix H - SDAP Response.pdf · 87 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.