MCU14/0073 Town Planning Report
SPECIFIC OUTCOMES PROBABLE SOLUTIONS COMPLIANCE COMMENTS
14.16 Effects of use
Electricity infrastructure S18.1 No solution provided YES The proposed extension will not adversely impact
O18 The development does not adversely impact on on existing or future electricity supply infrastructure.
existing or future electricity supply infrastructure;
AND
YES An electricity substation is located within the
O19 All uses and works maintain an adequate safe S19.1 Development for uses adjacent to or within 50m of
distance from electrical infrastructure including an existing electricity substation incorporates noise existing building; however, this is currently being
substations, overhead powerlines, power poles and attenuation measures to mitigate noise impacts; moved by Energex to the frontage of the subject
transformers. AND site.
S19.2 Buildings and structures (including swimming pools, YES All buildings and structures are sufficiently
sheds, tennis courts and outbuildings) are not constructed distanced from overhead electricity transmissions
under overhead electricity transmission lines, or within lines and easements.
electricity easements.
Noise No solution provided YES The approved development does not result in noise
O20 Development is designed and sited to avoid noise emissions that unreasonably diminish the amenity
emissions that unreasonably diminish the amenity of the of the area or surrounding uses.
area or surrounding uses.
Mechanical plant and equipment and storage areas S21.1 Mechanical plant and equipment are— YES All mechanical plant and equipment will be located
O21 Mechanical plant and equipment (including air a) located more than 2m from any property boundary; a minimum of two (2) metres from the property
conditioning equipment) and storage areas are designed b) where located at ground level, screened by fencing 1.5m boundary and will be visually integrated into the
and located to— in height or dense vegetation of at least 1.5m in width
a) avoid adverse visual impacts when viewed from the incorporating grouped trees and shrubs with maximum building and roof design (refer to proposal plans
street and adjoining properties; and separation distance of 1m measured from the centre of the prepared by Zenith Design within Appendix I).
b) visually integrate with the building design. tree or scrub; and
c) are visually integrated into the line and plane of the
building and roof design and do not project beyond the
height or width of the building when viewed from the street
and adjoining properties;
AND
S21.2 For Industrial business and Retail business Type YES Where materials are required to be stored outside
3, materials stored outside of a building do not exceed 4m of the building, these will not exceed 4.9 metres in
in height or half the height of the on-site buildings height. Please condition any future development
whichever is the greater.
permit accordingly.
Safety and security S22.1 Boundaries are identified by such means as - YES The boundaries of the Wimmers factory will be
O22 All property boundaries are clearly identifiable with a) fencing; or identified through fencing and landscape
public and private spaces clearly defined. b) changes in surface materials or levels; or treatments, as shown on the proposal plans
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
MCU14/0073 Town Planning ReportRelated documentApplication case desk ↗
About this file
- File size
- 8.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.