Council archive · source document
MCU14/0073 Town Planning Report
SPECIFIC OUTCOMES PROBABLE SOLUTIONS COMPLIANCE COMMENTS O10 Site cover does not exceed— Not result in clearing of existing a) for a class 1 or class 10a structure within the Detached vegetation and will provide additional Housing Zone, — landscaping on-site; i for a single storey building - 50%; or ii for a building of 2 or more storeys - 50% on the ground Allow for adequate area at ground floor and 30% for the upper storey(s), or 40% for all level for required facilities; and, storeys for a building of 2 or more storeys; Provide for sufficient on-site b) for other classes within the Detached Housing Zone - stormwater management and 40%; vehicular access. c) for the Semi-Attached Housing Zone—40%; or d) for the Attached Housing Zone—40% e) for the Community Services Zone—50% O11 For Multiple Housing Type 2 buildings have a maximum plot ratio of 0.45:1. O12 For Multiple housing Type 3 or 4, Visitor accommodation Type 4, or the accommodation unit component of an Entertainment and dining business Type 3—maximum gross floor area is equivalent to the maximum allowable population in persons multiplied by 40m2. O13 For the Business Centre Zone plot ratio does not exceed— a) 0.8:1 for site areas up to and including 2,000m2; and b) 0.3:1 for the balance of a site over 2,000m2. Flooding and drainage S14.1 For new buildings or structures or additions of more N/A Habitable rooms are not proposed. O14 Buildings and other works are designed and sited than 50m2 gross floor area to an existing building or to— structure, floor levels for habitable rooms are— a) provide flood free access to premises and flood free a) for areas where minimum floor levels are available—not habitable areas; less than the specified level; b) allow only minor, short term and infrequent flooding of b) for areas where flood modelling is available—a minimum non-habitable areas; of 500mm above the modelled flood level; and c) ensure carparking areas can be adequately drained; c) for areas where flood modelling is not available, a d) ensure drainage does not adversely impact upon other minimum of 500mm above the highest known flood level; premises; and AND
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
MCU14/0073 Town Planning ReportRelated documentApplication case desk ↗
About this file
- File size
- 8.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.