MCU14/0073 Town Planning Report
SPECIFIC OUTCOMES PROBABLE SOLUTIONS COMPLIANCE COMMENTS
e) ensure filling or excavation does not adversely impact S14.2 Where Council infrastructure is available— N/A With the exception of water, other Council
upon other premises by— a) any drainage (including buildings and yards) flows to infrastructure is not available to the subject
i. causing ponding of water on the site or nearby land; that infrastructure; and site. Existing stormwater drainage and
ii. increasing flooding, which adversely affects the safety b) the infrastructure has the capacity to accept any effluent disposal measures will be provided
or use of any land upstream and downstream; and additional loading; for the proposed development.
iii. adversely affecting the flow of water in any overland AND
flow path. S14.3 Car parking and maneuvering areas are constructed YES The existing car parking and manoeuvring
at a level that permits the parking area to drain from the areas will be utilised.
site by gravity means, without the need for mechanical
pumping; or
N/A Basements are not proposed.
S14.4 Basements for residential uses have flood immunity
above the Q100 where alternative means to mechanical
pumping are used to achieve such immunity; or
S14.5 Basements for non-residential uses have flood N/A As above.
immunity above the Q100 that may be achieved by means
of mechanical pumping where the mechanical feature is
installed with adequate holding tanks and an alternative
back up power source.
Sloping sites S15.1 Buildings are of split level design that step down the N/A New buildings are not proposed.
O15 On sloping sites, buildings and structures are slope or have a suspended floor construction; (See Figure
designed to maximise the use of natural slope and 6.1 below)
minimise the need for cut and fill. AND
S15.2 Cut or fill is less than 2m in depth; N/A Cut and fill is not proposed.
AND
S15.3 The distance between the ground and the lowest N/A The proposed extension will not result in split
part of the floor of the building does not exceed 3m. level design.
Figure 6.1—Design for sloping site (suspended floor)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
MCU14/0073 Town Planning ReportRelated documentApplication case desk ↗
About this file
- File size
- 8.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.